2GIG CT100 Operation Guide



Related Products

2GIG Z-CT100 - Z-Wave Programmable Thermostat
2GIG CT100
Z-Wave Programmable Thermostat

Document Transcript

PG 1
Operation Guide CT100
The CT100 communicating Z-Wave thermostat
operates via a high-quality, easy-to-use touch screen.
To set or adjust your CT100, simply touch your fnger
frmly to the screen. The screen will automatically light
up and you will hear a “beep.” Do not use a sharp or
metallic device; it will scratch the screen.
ENGLISH
Statement of use: 100% Compatible with all popular
residential HVAC systems; 24VAC single, two stage
conventional heating systems (gas/oil/electric), heat pumps
with up to two stages of heat and two stage auxiliary
heat(electric or fossil), zoned forced air and zoned hot water
(2 or 3 wire), millivolt systems (with a 12-24 AC or DC source),
one or two stage cooling, and hybrid systems.
1202-002-002
Power Grid
status
indicator
top cover
Touch screen
Wire
terminals
Mode
button
button
MENU
Reset
button
HVAC
selections
switches
bottom
cover
PG 2 PG 2
Control Screens
HOME Screen
Before you operate the CT100 please get familiar with these basic control screens. All the CT100
functions are accessed through these screens: HOME, MENU, and MANUAL. The CT100 touch
screen technology allows you to select (by touching) an item and change it using the +/- arrows or the
time arrows.

The HOME screen is displayed
when the unit is operating. Touching
the HOME icon on another
screen will always return you to this
screen.
To set a Mode:
Press the mode button on the front.
The CT100 will step through the
modes HEAT, OFF, COOL, OFF,
AUTO, OFF in order.
F
LINK
RADIO
TARGET TEMP
1
HEAT
AUTO
Thermostat
Temperature
Controls
Mode
Time
of Day
Current Room
Temperature
Radio
Indicator
Fan
Status

Target
Temperature

Set Time
Touch this area to set

the time of day.
Left arrow goes back,

right arrow goes forward.
Calibration control
Use this to calibrate your

LCD display match to
another thermometer
.
Set

o
C -
o
F
Touch this
to set temp

display units
Lock Program
Touch for 5 sec

to lock or unlock.
RECOVERY set
FAST or ECON
RADIO icon
Shows radio status

and connection

Chirp set
Touch this to turn the
audible chirp on or off.
Temperature
Swing set
Differential to set
for 2nd Stage start.

Return

to

HOME
screen.
HVAC SETUP
Touch this in OFF mode to

configure the unit to work with

your HVAC system.
DIFF ECON RECOVERY
FAST RECOVERY SWING
F
C
LINK
MATE
RADIO
2
CALIBRATE ON
HVAC
SETUP

PG 2 PG 2
PG 3
MENU Screen The MENU screen is the gateway to many functions or settings of the
CT100. It is displayed when you press the MENU button. [See page 10 for details]

Set Time
Touch this area to set

the time of day.
Left arrow goes back,

right arrow goes forward.
Calibration control
Use this to calibrate your

LCD display match to
another thermometer
.
Set

o
C -
o
F
Touch this
to set temp

display units
Lock Program
Touch for 5 sec

to lock or unlock.
RECOVERY set
FAST or ECON
RADIO icon
Shows radio status

and connection

Chirp set
Touch this to turn the
audible chirp on or off.
Temperature
Swing set
Differential to set
for 2nd Stage start.

Return

to

HOME
screen.
HVAC SETUP
Touch this in OFF mode to

configure the unit to work with

your HVAC system.
DIFF ECON RECOVERY
FAST RECOVERY SWING
F
C
LINK
MATE
RADIO
2
CALIBRATE ON
HVAC
SETUP

PG 4 PG 4
MANUAL Screen The Manual Screen control screen is where you can make
temporary changes to your CT100’s operation. From the HOME screen, touch the main temperature
display to use this screen. [See page 13 for details]
F
EMER
HEAT
Target

Temperature
Room
Temperature
Return HOME
Temp Up / Temp Down arrows
Touch these to raise and lower

the manual override Target Temp.
EMER

heat for
HEAT PUMP systems.
AUTO
PG 4 PG 4
PG 5
Initial Settings

Press MENU to access the following commands (from HOME screen).
Set time of day
Touch the Time of Day arrows to move the time selection forward or backward until
it displays the current time. Touch and hold for faster setting.
Set
o
F-
o
C display
Touch the
o
F and it will toggle to
o
C.
Set audible chirp
Touch the musical note icon to select the chirp
or no chirp.
Return HOME by touching the home icon.
Forward Backward
PG 6 PG 6
MENU Screen Functions


Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the CT100 setting and the room temperature required before the heating or cooling system
will turn on—Swing range: 0.5 to 4.0F (.25 to 2C). For example, if SWING is set to 2.0° F and the
CT100 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to
68°F. Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC
then runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 4.0°F (.25 to 2C).
The HVAC will run more frequently at 0.5°F and less at 4.0°F. Default is 1°F.
Touch to return to the MENU screen.
PG 6 PG 6
PG 7
Chirp set - Touch this to turn the audible chirp sound on or off.

F
C
Set - Touch this to switch the temperature display scale from
o
F to
o
C .
LOCK (The CT100 has 2 lock modes)
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily
override the CT100 target with the +/- buttons only. (1 bar)
For FULL lock : Touch the (1 bar) icon again for 5 seconds to go to full lock. No changes can be
made in full lock (2 bars). Once locked, the CT100 will respond just to MENU.
To UNLOCK , Press MENU.
Touch and hold icon for 5 seconds for 2 bars (if not there already).
Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate.
Touch to return to the Home screen.

PG 8 PG 8
CALIBRATE
Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient
temperature. You do have the option, however, to change the display temperature to match that of a
previous thermostat, or to match another thermostat already in your home. The range of change is
from -6°F to +6°F or -3°C to +3°C.

To change your Thermostat Calibration, touch MENU and then touch CALIBRATE.
Use the + / - to adjust the displayed temperature up or down, as desired.
The DELTA FACTOR that appears on the screen will also automatically increase or decrease
for each 0.5° (F or C) adjustment so you can see your change. The large display will show the
modifed temperature reading that will be displayed on the HOME screen and used as the new room
temperature.
Touch to return to the Home screen.
DIFF (Used for multiple stage systems only, not on screen for single stage)
The differential is the number of degrees between the room temperature and the Target Temperature
at which the 2nd stage will be used. Default is 2°F , range is 2°F to 6°F (1°- 3°C).
Touch MENU and then DIFF. Use the arrows to set the DIFF.
Recommend 2°F for very cold climates and the 6°F for warm climates.
PG 8 PG 8
PG 9
MANUAL Screen Functions

The CT100 has 2 manual override commands. The manual screen is accessed by touching the large
current temperature display in the middle of the HOME screen.
IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.
TEMPERATURE Touch the +/- arrows tot select your desired Target Temperature. Touch HOME to
return to operation.
EMER (in HEAT PUMP type)
If you set your CT100 for HEAT PUMP with auxiliary heat, EMER function is available on the
MANUAL screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and
auxiliary heat is your sole source of heat. This manual override stays active until you toggle EMER
off. Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot
keep up or is defective.
PG 10 PG 10
Other Functions

MODE Button
The mode button sets the CT100 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the
next mode. If the CT100 is in OFF and you want to return to the mode you were previously in, touch
the OFF indicator on screen.
FAN Button
The fan control is normally in AUTO mode, meaning that the fan operates automatically with the
HVAC system and the thermostat. When the fan button is pressed the fan goes ON; the fan will run
continuously in this manual override until switched back to AUTO by pressing the FAN button again.
[NOTE: Fan ON function is available in the OFF mode to allow simple ventilating.]
RESET button The RESET button re-boots the CT100 processor. It does not effect the target
temperatures that have been stored in permanent memory.
Compressor Protection The CT100 has a minimum cycle time of 4 minutes to protect your
compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and
A/C during this time and the compressor will not come on until the 4 minute delay is over.
PG 10 PG 10
PG 11
Communicating Thermostat

The CT100 has a built in Z-Wave radio. This allows your thermostat to
communicate with other systems.
Network INCLUSION
1. Set your primary controller to INCLUDE mode, to add the thermostat as a node on your network
(see your specifc controller’s User Manual for detailed instructions.)
2. Press and release the MENU button on the thermostat.
3. Press the MATE button - This will bring you to the network screen and a large r1 will be displayed.
4. Press the MATE button, this will initiate the mating process. When a device has joined a network
the word LINK will appear under the radio tower.
Your controller will indicate the thermostat was successfully added to its network (see your specifc
controller’s User Manual for details).
Network EXCLUSION
1. Set your primary controller to EXCLUDE mode, to remove the thermostat as a node on your
network (see your specifc controller’s User Manual for detailed instructions.)
2. Press and release the MENU button on the thermostat.
3. Press the MATE button - This will bring you to the network screen and a large r1 will be displayed.
4. Press the MATE button, this will initiate the mating process. When a device been removed from a
network the word LINK below the radio tower will disappear.
Your controller will indicate the thermostat was successfully removed from its network (see your
specifc controller’s User Manual for details).
PG 12 PG 12
Z-Wave and Battery Power
When your thermostat is running on battery power, the Z-Wave radio will turn off to help conserve
battery life. The CT100 Z-Wave radio module supports Z-Wave beaming, which allows other devices
in the network to wake up the Z-Wave module and accept commands, and then go back to sleep.
The node type is fxed during network inclusion. If C-Wire is not present and the thermostat is battery
powered during network inclusion, the thermostat will remain a frequent listening routing slave
(FLiRS) node until the thermostat is removed from the network via network exclusion.
Z-Wave and C-Wire Power
When your thermostat is running on C-Wire power, the Z-Wave radio will stay on and actively help
in routing messages within the z-wave network. The node type is fxed during network inclusion.
If C-Wire is present and powered during network inclusion, the thermostat will remain an always
listening node until the thermostat is removed from the network via network exclusion.
Caution
HVAC Setup and Z-Wave
Do not change the HVAC setup or HVAC selection switches if the thermostat is included to Z-Wave
network. The HVAC system must be changed, frst EXCLUDE the thermostat from the network,
change the HVAC setup, and INCLUDE the thermostat to the network.
PG 12 PG 12
PG 13
PG 14 PG 14
PG 14 PG 14
PG 15
PG 16 PG 16
PG 16 PG 16
PG 17