Interlogix TX-E221 - Installation Manual



Related Categories


Document Transcript

P/N
466
-
5250 • REV A • 25
APR
16





© 2016
United Technologies Corporation. All

rights reserved.









Installation Sheet


Enrolling

To enroll the sensor
,

set your panel into program mode. Then go to the Learn Sensors menu.
Refer to your specific alarm panel manual for details on these menus.
With the battery installed,
activate the case tamper by removing the cap on the transmitter. Press and release the tamper
switch on the top of the contact circuit board until the panel r
esponds to the sensor. Then select
the appro
priate sensor group and number.


Mounting

The recessed sensor and
magnet are designed to
fit tightly

in
a ¾
” (19.05mm)
hole
.

A

small flange
on the outer rim ensures the case cannot be pushed too far into
the

hole.


Choose a suitable location for the sensor

by following the procedure in the section “Testing the
Sensor” ensuring desired signal strength is achieved.

D
rill a ¾
” x
2.5


(19.05 x 63.5mm)
inch hole in
the door for the sensor. Mark the location for
the magnet in the frame directly in line with the sensor
and dri
ll a ¾” x

½
” (19.05 x 12.7mm)
hole for the magnet.


Where possible, install sensors within 100 ft. (30 m) of the panel. While a transmitter may have an
open
-
air range of 500 ft. (150 m) or m
ore, the environment at the installati
on site may have a
significant e
ffect on operational range. Changing a sensor location may improve wireless
communication.



Testing the Sensor (Test Weekly)

The sensor test verifies proper communication between the s
ensor and the panel/receiver. To test
the sensor, refer to the specific panel/receiver docu
mentation and do the following:


1. Put the panel/
receiver into sensor test mode.

2. Open the door/window the sensor is protecting.

The sensor transmits a signal.

3.

Listen for siren beeps to dete
rmine the appropriate response.

4. Exit sensor test mode
.



I
nstalling / Replacing
the Battery

When the battery is low
,

a signal will be sent to the control panel. To install/replace the battery:


1. Remove the cap on the
transmitter.

2. Take note of how the circuit board fits into groves on the side of the case.

3. Carefully slide out the circuit board.

4. Inspect the battery holder to determine which side the battery is inserted

/

removed.

5. Install /

replace with a CR
-
2

battery ensuring the + side of the battery faces the circuit board.

6. Re
-
insert the circuit board so that the board slides within groves in the plastics.

7. Once in, replace the cap.


Note
: Removing the cover will trigger a zone tamper signal to the cont
rol panel.



TX
-
E
221

Recess
ed

Door/
Window Sensor 319.5 MHz

P/N
466
-
5250 • REV A • 25
APR
16





© 2016
United Technologies Corporation. All

rights reserved.




Specifications


Frequency

319.5MHz

Battery

3V lithium
CR
-
2

Battery Life

5 years

Operating Temperature

32°
-
120°F (0°
-
49°C)

Operating Humidity

5
-
95% RH non condensing

Magnet Gap

1” (25.4mm)

max

Supervisory Signal Interval

60 min
(approximately)

Compatibility

Interlogix Learn Mode Panels and Receivers


FCC Compliance Statement


This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the F
CC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation.

T
his equipment generates,

uses
,

and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular install
ation
.


If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the eq
uipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:




Re
orient or relocate the receiving antenna.




Increase the separation between the equipment and receiver.




Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.




Consult the dealer or an experienced

radio/TV technician for help.


Changes or modifications not expressly approved by UTC Fire and Security could void the user’s authority to operate the equip
ment.


This device complies with Industry Canada
license
-
exempt RSS standard(s). Operation is subj
ect to the following two conditions: (1) this device may not cause
interference,

and (2) this device must accept any interference, including interference that may cause undesired operation of the device.


Cet appareil est conforme avec Industrie Canada exe
mpts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet
appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris celles pouvant

causer un mauvais fonctionn
ement
de l'appareil.

In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be installed such

that a minimum separation
distance of 20 cm is maintained from the general population.


FCC: XQC
-
WST221

IC: 9
863B
-
WST
221


This Class B digital apparatus complies with Canadian ICES
-
3B.

Cet appareil numérique de la classe B est conforme à la norme NMB
-
003 du Canada.


Contact information

For contact information, visit us online at www.interlogix.com.

For technical
support, see www.interlogix.com/support


Copyright

Copyright © 2016 United Technologies Corporation. All rights reserved.


Trademarks

Interlogix is a registered trademark of United Technologies Corporation. Interlogix is part of UTC Climate, Controls &

Security, a unit of United Technologies
Corporation.


Limitation of Liability

A PROPERLY INSTALLED AND MAINTAINED ALARM/SECURITY SYSTEM MAY ONLY REDUCE THE RISK OF EVENTS SUCH AS BREAK
-
INS,
BURGLARY, ROBBERY OR FIRE; IT IS NOT INSURANCE OR A GUARANTEE TH
AT SUCH EVENTS WILL NOT OCCUR, THAT ADEQUATE WARNING OR
PROTECTION WILL BE PROVIDED, OR THAT THERE WILL BE NO DEATH, PERSONAL INJURY, AND/OR PROPERTY DAMAGE AS A RESULT.

WHILE INTERLOGIX UNDERTAKES TO REDUCE THE PROBABILITY THAT A THIRD PARTY MAY HACK, CO
MPROMISE OR CIRCUMVENT ITS
SECURITY PRODUCTS OR RELATED SOFTWARE, ANY SECURITY PRODUCT OR SOFTWARE MANUFACTURED, SOLD OR LICENSED BY
INTERLOGIX, MAY STILL BE HACKED, COMPROMISED AND/OR CIRCUMVENTED.

INTERLOGIX DOES NOT ENCRYPT COMMUNICATIONS BETWEEN ITS A
LARM OR SECURITY PANELS AND THEIR OUTPUTS/INPUTS INCLUDING,
BUT NOT LIMITED TO, SENSORS OR DETECTORS UNLESS REQUIRED BY APPLICABLE LAW. AS A RESULT THESE COMMUNICATIONS MAY BE
INTERCEPTED AND COULD BE USED TO CIRCUMVENT YOUR ALARM/SECURITY SYSTEM.


WARRAN
TY DISCLAIMERS

INTERLOGIX HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS, WHETHER EXPRESS, IMPLIED, STATUTORY OR OTHERWISE
INCLUDING (BUT NOT LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS
SECURI
TY PRODUCTS AND RELATED SOFTWARE. INTERLOGIX FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM
COMPUTER INFORMATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE.

(USA ONLY) SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTI
ES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE.

INTERLOGIX MAKES NO REPRESENTATION, WARRANTY, COVENANT OR PROMISE THAT ITS SECURITY PROD
UCTS AND/OR RELATED SOFTWARE
(I) WILL NOT BE HACKED, COMPROMISED AND/OR CIRCUMVENTED; (II) WILL PREVENT, OR PROVIDE ADEQUATE WARNING OR PROTECTION
FROM, BREAK
-
INS, BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK PROPERLY IN ALL ENVIRONMENTS AND APPLICATIONS.


DISCLAIMER

THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. UTC ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR
OMISSIONS AND SPECIFICALLY DISCLAI
MS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE, INCURRED AS A CONSEQUENCE,
D
IRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION,
CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW.INTERLOGIX.COM

THIS PUBLICATION MAY CONTAIN EXAMPLES OF SCREEN CAPTURES AND REPORT
S USED IN DAILY OPERATIONS. EXAMPLES MAY INCLUDE
FICTITIOUS NAMES OF INDIVIDUALS AND COMPANIES. ANY SIMILARITY TO NAMES AND ADDRESSES OF ACTUAL BUSINESSES OR PERSONS IS
ENTIRELY COINCIDENTAL.


INTENDED USE

USE THIS PRODUCT ONLY FOR THE PURPOSE IT WAS DESIGNED FOR; REFER TO THE DATA SHEET AND USER DOCUMENTATION. FOR THE
LATEST PRODUCT INFORMATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT
WWW.INTERLOGIX.COM


THE SYSTEM SHOULD BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST EVERY 3 YEARS AND THE BACKUP BATTERY REPLACED AS
REQUIRED.


Uploaded