MyWebTech
Technical Notification #137
Technical Updates Directly
Technical Notification #137
11/18/2025
Subject:
ProSeries Advisory for Panel Replacement Scenarios
Produ
ct
PROA7-FA and PROA7PLUS-FA Control Panels
November 18, 2025
Dear Valued Customer,
Resideo has determined a scenario where enrolled Pr
oSiX Sensors may become unenrolled
during a ProSeries panel replacement and cannot be
re-enrolled, requiring physical replacement
of the affected sensors.
This scenario specifically occurs when installing a
PROA7-FA or PROA7PLUS-FA with
firmware
version 03.2476.174
as a replacement for a previously installed ProSer
ies control panel.
Please note the following:
•
Other wireless sensor technologies that communicate
through the PROTAKEOVER module
or previously included motion viewers are not affec
ted the same way. While these sensors
may be removed from the programming, they can be re
-enrolled without physical
replacement.
•
NEW installations are not impacted; however, we rec
ommend including all applicable
firmware updates in your standard installation chec
klist.
Resoluon and Required Acon:
Firmware version
03.2476.183
has been released to resolve this issue. Updated p
anels are
available at local distribu7on centers.
Before performing any panel replacement, confirm tha
t the replacement panel has firmware
version 03.2476.183 or higher installed.
The panel firmware version can be verified on the MAC
address label located on the product
packaging, when purchasing or prior to install.
We apologize for any inconveniences this may have c
aused and thank you for your con7nued
support of Resideo products. If you have been impac
ted by this issue or have
any ques7ons or
require further assistance, please contact your loc
al sales representa7ve,
Resideo Customer
Service or Technical Support at 1-800-222-
6525 op7on 3.
Sincerely,
Product Marke7ng Team
Resideo Technologies, Inc.