Qolsys IQ Keypad-PG - User Guide - Dated 07/10/2024



Related Products

Qolsys IQKP-PRX-915 - IQ Prox PowerG Keypad w/ 4 Tags
Qolsys IQKP-PRX-915
IQ Prox PowerG Keypad w/ 4 Tags
List Price:
Our Price: $119.99
Qolsys IQKP-915 - Capacitive Touch PowerG IQ Keypad
Qolsys IQKP-915
Capacitive Touch PowerG IQ Keypad
List Price:
Our Price: $88.99

Document Transcript

IQ Keypad is a battery powered, capacitive touch keypad for use with compatible IQ4 NS, IQ4 Hub &
IQ Panel 4 platforms via the PowerG protocol. It provides an easy and intuitive interface to control
basic features of the system. This manual covers both IQ Keypad-PG and IQ Keypad Prox-PG models.
Document: IQKP-UG
Version: 1.0.0
Date: 07/10/2024
IQ KEYPAD USER GUIDE USING YOUR SYSTEM: OVERVIEW
Prox Tag Reader
(IQ Keypad Prox-PG only)
Arm Stay
Arm Away
Arm Night
Trouble LED
The “Lock” LED indicates “Armed Status” (solid ON),
“Alarm Condition” when flashing 1/s and “Alarm
Conditions with Bell Silenced” when flashing 2/s
Disarmed Status
LED
Fire Emergency
(1+3)
Hold for 2 sec
Police Emergency
(7+9)
Hold for 2 sec
Aux Emergency
(4+6)
Hold for 2 sec
Wake Area USING YOUR SYSTEM: BASICS
KEYPAD STATUS LIGHTS:
Status lights help you understand the state of the system at a glance.
USING YOUR IQ KEYPAD
Status Lights
LED
Description
OFF
Not ready to Arm.
ON
Ready to Arm.
FLASHING
Ready to Arm, bypass-able zones are open.
OFF
Disarmed
ON
Armed
FLASHING (1/s)
Alarm condition
RAPID FLASHING (2/s)
Alarm condition with bell silenced for Fire Alarms
OFF
No Trouble
ON
System Trouble
FLASHING
Keypad Low Battery
Key
Description
Arm Stay
Arm Away
Arm Night
ARMING KEYS:
Arming keys are the primary way of controlling the system from the IQ Keypad.
NOTE: If successful, the Armed Status LED will flash twice. If communication is not successful, the keypad flashes all keypad
number LED’s (backlight) 0.5 seconds ON/OFF twice. Press and hold any arming key for more than 2s for Silent Arm.
Key
Description
Arm Stay + [Access Code] or [Prox Tag]
Arm Away + [Access Code] or [Prox Tag]
Arm Night + [Access Code] or [Prox Tag]
SECURE ARMING:
When Secure Arming is enabled on the primary panel, a valid 4 - 6 digit users code is required to Arm the system.
NOTE: If RF Jam Trouble or Loss of Communication is detected, all LED’s will flash in the following sequence: ON for 0.5s,
then OFF for 0.5s -repeating 3x in a row, 2 second break, then start over. The user shall always check the IQ Keypad to asses
the status of the system.
The indications on the keypad are always active for the duration of the condition being present in the system, keypad can go
to sleep mode to save battery life, wake up by pressing above IQ Keypad logo, the indications will be visible again to the end
user. DISARMING KEYS:
Disarming from the IQ Keypad is easy. Simply enter a valid 4 - 6 digit code into the
keypad and the system will disarm.
USING YOUR SYSTEM: BASICS
Key
Description
Press and hold both the 1 & 3 keys simultaneously to generate a fire alarm.
Press and hold both the 4 & 6 keys simultaneously to generate an auxiliary
emergency alarm.
Press and hold both the 7 & 9 keys simultaneously to generate a police panic alarm.
EMERGENCY KEYS:
Emergency keys allow you to trigger an emergency panic directly from the IQ Keypad.
NOTE: Press and hold emergency keys for two seconds
PROX TAG SUPPORT:
For “IQ Keypad Prox-PG” models that support Prox Tags, you may Arm with a Prox Tag in place of a 4 - 6 digit
code if Secure Arming is enabled and by pressing the Arming icon of choice, followed by presenting your tag in
front of the bullseye icon on the lower right hand side of the keypad. If the system is armed, presenting a valid
Prox Tag will disarm it.
NOTE: If successful, the Armed Status LED will flash twice. If communication is not
successful, the keypad flashes all keypad number LED’s (backlight) 0.5 seconds ON/
OFF twice.
WAKING THE IQ KEYPAD
To conserve battery, the IQ Keypad enters an
idle state when not in use.
To wake the IQ Keypad, tap above the IQ
Keypad logo. The IQ Keypad’s LED backlight
will illuminate and the device will be ready to
use.
Touch HERE
to wake USING YOUR SYSTEM: BASICS
PARTITION ARMING:
The Hash Menu on the IQ Keypad allows access to Partition Arming functionality. It may also act as a “Home”
button to back out of any button press activity and start over. See table below for a list of functions.
Press
Action
[#][1] + [Arm Stay] + [Access Code] or [Prox]
Arm Partition 1 to Stay
[#][2] + [Arm Stay] + [Access Code] or [Prox]
Arm Partition 2 to Stay
[#][3] + [Arm Stay] + [Access Code] or [Prox]
Arm Partition 3 to Stay
[#][4] + [Arm Stay] + [Access Code] or [Prox]
Arm Partition 4 to Stay
[#][1] + [Access Code] or [Prox]
Disarm Partition 1
Hold [#] for 2 Seconds
Erases any current button presses
NOTE: When a Fire Alarm occurs (Temporal three pattern), the Bell sounding can be silenced by entering the valid user code.
The "LOCK" indicator will start flashing rapidly (2/s) indicating that a fire alarm condition with bell silenced exists in the
system. The Fire alarm will be reset only when the fire initiating device has been restored.
The same functionality will also be for Carbon Monoxide alarms (Temporal four pattern).
For Fire Alarms and CO Alarm always follow the evacuation plan as suggested in your alarm system manual.
When a Burglary Alarm occurs (continuous pattern), the alarm can be reset by entering a valid user code.
Note: For UL certified Commercial Burglary Central Station applications the IQ Keypad provides an acknowledgment signal
to the user interface to confirm that normal closing signal has been received once the system has been armed. The device
causes an audible indication (eight short beeps) when it receives the acknowledgment signal transmitted from the
monitoring station compatible receiver.
Press
Action
[*][0]
Starts keypad cleaning mode and lasts for 30 seconds.
Alarms, entry and exit delay will cancel screen cleaning
[*][1] + [Access Code]
Bypass all open Zones
[*][2] + [Access Code]
Silences Troubles
[*][4] + [Access Code]
Toggle Chime On/Off
[*][6] + [Access Code]
Toggle Keypress Buzzer On/Off
[*][7] + [Output #] + [Access Code]
Toggle Command Output (for future use)
[*][8] + [Access Code]
Turn on Installer Programming Access (EN Grade 2 only)
[*][9] + [Access Code]
Arm System with No Entry Delay
STAR MENU:
The Star Menu on the IQ Keypad allows access to more advanced functionality such as silent arming, bypassing
zones, turning on/off the chime, buzzer and more. See table below for a list of functions
NOTE: All * menus will follow secure arming option whether an access code is needed or not
NOTE: feature no allowed to be
used on UL/cUL installations LEGAL
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1.
this device may not cause harmful interference, and
2.
this device must accept any interference received, including interference that may cause undesired operation.
Please note that changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
RF EXPOSURE STATMENT
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. In order to avoid
the possibility of exceeding the FCC radio frequency exposure limits, this equipment should be installed and operated
with minimum distance 20 cm (7.9 inches) between the antenna and your body during normal operation. Users must
follow the specific operating instructions for satisfying RF exposure compliance.

ISED CANADA NON-INTERFERENCE DISCLAIMER

This device contains licence-exempt
 
transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

1.
This device may not cause interference.

2.
This device must accept any interference, including interference that may cause undesired operation of the
device.

This device complies with the Canadian ICES-003 Class B specifications. CAN ICES-003(B) / NMB-003 (B).
L’émetteur/récepteur exempt de licence
 
contenu dans le présent appareil est conforme aux CNR d’Innovation,
Sciences et Développement économique Canada applicables aux appareils radio exempt de licence. L’exploitation est
autorisée aux deux conditions suivantes :

1.
L’appareil ne doit pas produire de brouillage;

2.
L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.

Cet appareil numérique de la Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada. LEGAL
ISED CANADA RF EXPOSURE STATMENT
This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20 cm between the radiator and any part of your
body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Cet équipement est conforme aux limites d’exposition aux radiations ISED CNR-102 établies pour un environnement
non contrôlé. Une distance de séparation d'au moins 20 cm doivent être maintenue entre l'antenne de cet appareil et
toutes les personnes. Lanceurs ou ne peuvent pas coexister cette antenne ou capteurs avec d’autres.

CE

&

EN

COMPLIANCE

STATEMENT
Hereby, Qolsys Inc declares that the radio equipment type is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
IQ Keypad - PG:
http://dsc.com/2405002

IQ Keypad Prox - PG:
http://dsc.com/2405001

Frequency band and Maximum Power
433,22 MHz - 434,62 MHz: 10mW
869.0 MHz - 868.6 MHz: 17.2mW
868,7 MHz - 869,2 MHz: 17.2mW
119 KHz - 135 KHz: 2.61db
μ
A/m @ 3 m
European single point of contact: Tyco Safety Products, Voltaweg 20, 6101XK Echt, Netherlands.
This installation sheet applies to models IQ Keypad - PG and IQ Keypad Prox - PG.
The Model IQ Keypad - PG and IQ Keypad Prox - PG keypads have been certified by Kiwa Nederland BV according to
EN50131-1:2006+ A1:2009 + A2:2017+A3:2020, EN50131-3:2009 for Grade 2, Class II.
Caution: Do not dispose of the waste battery as unsorted municipal waste. Consult your local rules and/or laws
regarding recycling of this battery.


Uploaded