Qolsys IQ Switch-PG - Installation Guide - Dated 2023



Related Products

Qolsys IQ Switch-PG - PowerG In-Wall Switch for Qolsys Panels
Qolsys IQ Switch-PG
PowerG In-Wall Switch for Qolsys Panels
List Price:
Our Price: $45.99

Document Transcript

IQ Power Switch-PG Installation Guide
Safety information
WARNING:

Follow local electrical codes and regulations in your region when performing electrical work.

Only qualified professionals should handle electrical wiring/devices.

Install and use this product in accordance with applicable electrical codes and regulations in
your region.

The device is designed for indoor use in dry locations only.

Keep this manual as it contains important technical data, testing, and troubleshooting
information which may be useful after installation is complete.

The IQ Power Switch-PG is not compatible with standard 3-way or 4-way switches.

Do not attempt to disassemble the product or make repairs yourself. Doing so may result in
electric shock and void the limited warranty.

Do not exceed the maximum rated power of this device. For further information, see
Specifications
.

If you require assistance, contact our after-sales services.

Make sure to use this product together with a 15A circuit breaker.
Overview
The IQ Power Switch-PG is a wireless smart device that lets you control your indoor lighting
remotely through your control panel. For panels that are compatible with the IQ Power Switch-PG,
see https://bit.ly/3PwPksX
.
Figure 1:
Overview
Callout
Description
1
LED indicator
2
Load wire colored red
D-308963
*D-308963*
D-308693

Rev 00
D-308963 IQ Power Switch-PG Install Guide Callout
Description
3
Neutral wire colored white
4
Line (hot) wire colored black
5
Off button
6
On button
Installing the device
WARNING:
Before installing the device, make sure that the electricity supply to the area is
turned off. Failure to do so may result in electric shock or serious injury.
1.
Turn off the power at the circuit breaker.
2.
Remove the existing switch and connect the new switch according to Figure 2 and Figure 3.
Figure 2:
Wiring diagram
G
r
ou
n
d
Load
Not used
Li
n
e
Li
n
e/Hot
Neut
r
al
Load
Neut
r
al
120V~
60Hz
Figure 3: Connecting the switch
Callout
Description
1
Line wire (hot) coloured black
2
Neutral wire coloured white
3
Ground wire coloured green
4
Load wire coloured red
3.
Mount the switch with the screws and attach the faceplate, see
Figure 4.
IQ Power Switch-PG Installation Guide
2
D-308963 IQ Power Switch-PG Install Guide Figure 4: Mounting the switch
4.
Turn power on at the circuit breaker.
Enrolling the device with Auto Learn Enroll
Before you begin:
Ensure power is connected to the device.
1. On the IQ panel menu, select
Settings > Advanced Settings > Enter Installer Code >
Installation > Devices > Automation > Auto Learn Devices.
2.
Press and hold the On and Off buttons for 2 seconds or until the LED turns orange.
3.
Release both buttons and the LED turns off. The device enters enrollment mode, and the panel
is notified of the device initiating enrollment.
4.
When the device is recognized, tap
OK
when the pop-up window appears. Enter the device
details in the next configuration pop-up window.
5.
Optional:
Enter the PIN code on the product label for increased security during enrollment. The
device does not pair with the panel if you enter an incorrect PIN code.
6.
Tap
Pair
.
7.
If the device does not automatically enroll, perform a factory reset as indicated in the Resetting
the device section of the user manual.
Result
: The device enrolls successfully.
Enrolling the device with Add PowerG
Before you begin:
Ensure power is not connected to the device.
You can enroll the device in the IQ panel using the Add PowerG feature or scan the QR code on
the box. To enroll the device in the IQ panel using the Add PowerG feature, complete the following
steps:
1. On the IQ panel menu, select
Settings > Advanced Settings > Enter Installer Code >
Installation > Devices > Automation > Add PowerG.
2.
Enter the sensor id in the Sensor ID field or scan the QR code on the box label to enroll the
device.
3
IQ Power Switch-PG Installation Guide
D-308963 IQ Power Switch-PG Install Guide 3.
Optional:
Enter the PIN code on the product label for increased security during enrollment. The
device does not pair with the panel if you enter an incorrect PIN code.
4.
Tap
Pair.
5.
Plug in and power on the device.
Result:
The device enrolls successfully.
Considerations when you enroll a device
The following considerations apply when you enroll a device with PowerG or when you enroll a
device with Auto Learn enroll.

If the buttons remain pressed after the light is turned off, the device returns to low-power
mode.

If the connection is successful, the PowerG signal strength displays on the device and the
enrolled status on the control panel.
• If the connection fails, a
Not enrolled
status indicates on the control panel.
Checking the PowerG signal strength of the device
1.
Ensure that the IQ Outdoor Plug-PG is powered on.
2. On the IQ panel, tap
Settings > Advanced Settings > Enter Installer Code > Installation >
System Tests > PowerG Test > Run
.
PowerG signal strength indication
Table 1:
PowerG signal strength
Signal strength
LED color and pattern
Strong
LED turns green and flashes 3 times
Good
LED turns orange and flashes 3 times
Poor
LED turns red and flashes 3 times
IQ Power Switch-PG Installation Guide
4
D-308963 IQ Power Switch-PG Install Guide LED indication and configuration

LED flashes orange 3 times when delay off is activated.
Table 2:
Device configuration state
#
Configuration
Definition
1
Activation LED enabled
LED turns green when the load is on. LED does not
turn green when the load is off.
2
Activation LED disabled
LED is always off.
Note:
The IQ Dimmer-PG and IQ Power Switch-
PG operations that require feedback overrides
the Activation LED disabled mode. These opera-
tions are the PowerG signal strength test and the
Delay Off Timer.
Note:
If the connection fails and the LED indicator turns off, reset the device to factory
default. For more information see,
Resetting the device.
Manual operation
Table 3:
Device operations
Action
Status
Function
On
Turns the light Off.
Short press the Off button
Off
Keeps the light Off.
On
Keeps the light On.
Short press the On button
Off
Turns the light On.
Double click the Off button
On
Switches the light Off after a 5 minute
delay as hardware default.
Short press the Off button
Delayed Off
Immediately turn Off the load and
cancel the delay timer.
Short press the On button
Delayed On
Immediately turn Off the load and
cancel the delay timer.
Additional behavior of the device
Behavior
Corresponding behavior
Control the light on or off using the built-in
button
The IQ Panel updates the status within 10
seconds.
When enrolled
The IQ Panel registers the device as a PowerG
device.
When power is removed from the device
The IQ panel updates the device status to
unreachable within 14 minutes.
When power is restored to the device
The IQ panel automatically updates the device
status to normal within 5 minutes.
When communication is lost and then restored
The IQ panel automatically updates the device
status to normal within 5 minutes.
5
IQ Power Switch-PG Installation Guide
D-308963 IQ Power Switch-PG Install Guide Resetting the device
1.
Press and hold both on and off buttons for at least 2 seconds. The LED turns orange to
indicate a long press.
2.
Release briefly and press and hold both buttons again for 5 seconds until the LED turns red
and flashes 3 times to indicate a back to factory default reset.
Note:
After a device is reset back to factory default, you must delete it from the panel
and re-enroll the device.
Troubleshooting
WARNING:
The wiring should only be changed in accordance with applicable electrical codes
and regulations in your region.
WARNING:
Only a qualified professional should attempt to change electrical wiring.
Light flickering
• The light needs a better connection.

Wires need to be secured firmly under the terminal screws of IQ Power Switch-PG.
Light does not turn on and LED indicator does not turn on

Check if the circuit breaker or fuse has tripped.

Check if the light is burned out or if the light's neutral connection is not wired correctly.
Unable to control the lights remotely

Check if the IQ Power Switch-PG is connected to the IQ panel and ensure the wiring is correct.
Specifications
Frequency
912-919 MHz
Protocol
PowerG
Maximum noise
24dB at 20cm
Maximum load
Incandescent 600W, CFL/LED 300W
Standby power consumption
<1W
Power supply
120V at 60Hz
Maximum current
5A
Wiring
Direct wire connection, wire gauge 16 AWG
Humidity
0 to 85%, non condensing
Operating temperature range
0°C to 40°C or 32°F to 104°F
Storage temperature range
-20°C to 60°C or -4°F to 140°F
Device weight
116g
IQ Power Switch-PG Installation Guide
6
D-308963 IQ Power Switch-PG Install Guide Compliance with standards
FCC and ISED Canada Compliance Statement
This device complies with FCC Rules Part 15 and with ISED license-exempt RSS standard(s).
Operation is subject to two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
that may be received or that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
To comply with FCC Section 1.1310 for human exposure to radio frequency electromagnetic fields
and IC requirements, implement the following instruction:
A distance of at least 20 cm. between the equipment and all persons should be maintained during
the operation of the equipment.
Le dispositif doit être placé à une distance d'au moins 20 cm à partir de toutes les personnes au
cours de son fonctionnement normal. Les antennes utilisées pour ce produit ne doivent pas être
situés ou exploités conjointement avec une autre antenne ou transmetteur.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.
WARNING:
Changes or modifications to this equipment not expressly approved by the party
responsible for compliance (DSC.) could void the user’s authority to operate the equipment.
UL/ULC notes
The IQ Power Switch-PG has been listed by ETL for home automation applications in accordance
with the requirements in the Standards UL 60730-1:2016 Ed.5 for contacts and switches. For UL/
ULC installations use this device only in conjunction with compatible wireless receivers: Qolsys
7
IQ Power Switch-PG Installation Guide
D-308963 IQ Power Switch-PG Install Guide IQ4, IQ4 Hub. After installation, verify the product functionality in conjunction with the compatible
receiver used.
Safety Instructions
Read the safety information before you install the equipment.
The device shall be installed and used within an environment that provides the pollution degree
max 2 and over voltages category II in non-hazardous locations, indoor only. This product is to
be installed or used in accordance with local electrical codes and regulations. The device is to be
installed in an indoor dry location. Exposure to weather or corrosive conditions may damage the
unit.
W.E.E.E Product recycling declaration
For information regarding the recycling of this product you must contact the
company from which you originally purchased it. If you are discarding this
product and not returning it for repair then you must ensure that it is returned
as identified by your supplier. This product is not to be thrown away with
everyday waste.
Directive 2012/19/EU Waste Electrical and Electronic Equipment.
Limited Warranty and EULA
To access Warranty and EULA information, access the following link: https://bit.ly/3PwPksX
or scan
the following QR code:
Technical support
Intrusion Tech support: +1- 855-476-5797 #2 or 1-800-387-3630

©2023 Johnson Controls. All rights reserved. JOHNSON CONTROLS, TYCO and DSC are trademarks and/or registered
trademarks. Unauthorized use is strictly prohibited.
D-308963 IQ Power Switch-PG Install Guide
www.johnsoncontrols.com


Uploaded