UltraTech 1250F1 - Data Sheet
Related Products
Document Transcript
3.06 Ibs (1.39 Kg)
75A (5s)
Approx 48mΩ
Initial Charging Current less than 35A.
1.
Voltage
0
0
0
13.5V~13.8V at 77 F(25 C)Temp. Coefficient -10mV/
F
Specifications
Rated Voltage
(C
,
1.75V/cell
,
20hrs)
20
Temperature Effect on Capacity
ABS
Standby/Float Use
IM
series batteries may be stored for up to 6 months
0
0
at 77 F(25 C) and then a freshening charge is required.
For higher temperatures - time interval will be shorter.
12V
103%
100%
86%
0
0
77
±
5 F (25
±
3 C)
F
1
Layout
104 F (40 C)
0
0
77 F (25 C)
0
0
32 F ( 0 C)
0
0
(25 )
0
C
(25 )
0
C
0
0
5
~
122 F (-15
~
50 C)
0
0
-4
~
104 F (-20
~
40 C)
0
0
5
~
104 F (-15
~
40 C)
Discharge
Charge
Storage
Dimensions
1
2
.
76
±
0.04
3
.
54
±
0.04
3
.
98
±
0.08
4
.
21
±
0.08
2.85
F
1
0
.
03
0
.
10
0
.
17
0
.
19
0
.
06
0
.
26
3.54 inches ( 90
±
1mm)
2.76 inches ( 70
±
1mm)
3.98 inches (101
±
2mm)
4.21 inches (107
±
2mm)
Product Data Sheet
IM
Series:
IM-1250
F1
(
UT-1250
F1
)
12 Volt, 5.0 Amp. Hour
5.0Ah
C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV
C.O.V - Cutoff Voltage/cell.
The battery is fully charged & being discharged to COV
0
0
Constant Current Discharge (Amperes) at 77 F(25 C)
0
0
Constant Power Discharge (Watts/cell) at 77 F(25 C)
F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h
3h
4h
5h
6h
8h 10h 20h
1.85V/cell 11.3 8.26 6.55 5.35 4.07 2.99 2.44 1.84 1.53 1.09 0.876 0.744 0.637 0.500 0.425 0.244
1.80V/cell 12.2 8.69 6.81 5.51 4.17 3.04 2.48 1.87 1.56 1.11 0.888 0.755 0.645 0.507 0.430 0.246
1.75V/cell 13.1 9.10 7.06 5.68 4.27 3.11 2.53 1.90 1.58 1.13 0.900 0.765 0.653 0.513 0.436 0.250
1.70V/cell 14.1 9.50 7.31 5.84 4.37 3.16 2.57 1.94 1.61 1.14 0.910 0.775 0.662 0.519 0.441 0.252
1.67V/cell 14.8 9.80 7.46 5.95 4.43 3.20 2.60 1.95 1.62 1.15 0.920 0.780 0.667 0.523 0.444 0.254
1.60V/cell 16.0 10.40 7.80 6.17 4.56 3.29 2.66 2.00 1.66 1.17 0.940 0.795 0.679 0.532 0.450 0.256
F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h
3h
4h
5h
6h
8h 10h 20h
1.85V/cell 21.3 15.8 12.6 10.3 7.86 5.79 4.74 3.59 3.01 2.15 1.73 1.47 1.26 0.990 0.844 0.543
1.80V/cell 23.0 16.5 13.1 10.5 8.02 5.89 4.82 3.65 3.04 2.18 1.75 1.49 1.28 1.01 0.854 0.548
1.75V/cell 24.7 17.2 13.4 10.8 8.18 5.98 4.89 3.69 3.09 2.21 1.76 1.50 1.29 1.02 0.864 0.554
1.70V/cell 26.4 17.9 13.9 11.1 8.33 6.07 4.96 3.74 3.12 2.23 1.79 1.52 1.31 1.03 0.874 0.559
1.67V/cell 27.4 18.4 14.0 11.3 8.42 6.13 5.00 3.77 3.15 2.25 1.80 1.53 1.31 1.04 0.879 0.563
1.60V/cell 29.5 19.3 14.6 11.6 8.63 6.26 5.09 3.83 3.20 2.29 1.83 1.56 1.33 1.05 0.892 0.572
(20hr,0.250A,1.75V/cell)
(10hr,0.436A,1.75V/cell)
(5hr,0.765A,1.75V/cell)
(3hr,1.13A,1.75V/cell)
(1hr,2.66A,1.60V/cell)
5.00 Ah
4.36 Ah
3.83 Ah
3.39 Ah
2.66 Ah Standby
Float Charging Characteristics
/
Temperature Effectes on Battery
Capacity
Applications
Temperature Effectes on Long Term Float Life
Battery Temperature
Battery Temperature
Stand
ards
General Features
Discharge Characteristics
Sales Offices
Sales: 1.800.233.6261
Website: www.adiglobaldistribution.us
www.
ad
i
g
l
oba
l
d
i
s
t
ri
bu
t
i
o
n.
ca
2
Publication No.: LB-
-PD-ADI-V1.1-202106
IM-1250F1
Curves represent Constant Current draw ( Amp.)
1C curve = 1 x Nominal capacity= 4.5amp. constant draw 0.05C curve = 0.05 x Nominal capacity = 0.225amp. draw
• Uninterruptable Power Supply (UPS)
• Emergency backup power supply
• All purpose
• Auto control system
• Communication power supply
• Alarm and security system
• DC power supply
• Electric Power System (EPS)
• UL, CE Certified
• Compliance with IEC 60896 standards,
EU Battery Directive
• High quality AGM separator: extend cycle life
and prevent micro short circuit
Special exhaust structure and sealing technology,
safe and reliable, flexible installation, convenient
maintenance
•
High purity PbCaSn raw material alloy is used for plate
grids, assuring less gassing & low self-discharge rate
•
•
0
5 years design life(
77 F
)
• Manufactured in IATF16949,ISO45001,
ISO 9001 and ISO 14001 certified
production facilities
0.05C
0.1C
0.2C
0.4C
0.6C
1C
2C
3C
10
1
2
4
6
20
40
60
2
4
6
8
10
H
Min
8
20
8
9
10
11
12
13
(
V
)
12V
Battery
Terminal Voltage(V)
Discharge Time
0
0
Temperature:77 F(25 C)
0
8
16
20
12
24
28
32
36
40
(V)
(XCA)
%
Charge
Volume
Charging
Current
Charging
Voltage
After 100% Discharge
Charge Voltage
(Constant 2.25v/cell)
Charging Current
4
12
13
14
15
11
0.10
0.15
0.20
0.25
0.05
0
0
10
20
30
50
40
60
70
80
90
100
120
110
Charging Time(hours)
After 50% Discharge
Charged Volume
0
0
0.10CA-2.25V/cell Temperature
77 F(25 C)
0.25CA
0.17CA
0.1CA
Capacity
(
%
)
20
40
60
80
100
120
-
20
-
10 0 10 20 30 40 50 60
o
C
o
F
-
4
32 5
0
68
14
122
10486
140
Float
life
(
year
)
2
3
4
5
0
20
25
30
35
40
45
50
o
C
o
F
122
104
86
77
95
113
68
1
VdS
Product Data Sheet
IM
Series:
IM-1250
F1
(UT-1250
F1
)
12 Volt, 5.0 Amp. Hour
- Uploaded