UltraTech 1272F2 - Data Sheet



Related Products

UltraTech 1272F2 - Alarm Control Panel Battery Backup 12V 7Ah
UltraTech 1272F2
Alarm Control Panel Battery Backup 12V 7Ah
List Price: $60.00
Our Price: $40.99

Document Transcript

7.
0
Ah
4.34 Ibs (1.97 Kg)
105A (5s)
Approx 33mΩ
Initial Charging Current less than 1A.
2. Voltage
0
0
0
13.5V~13.8V at 77 F(25 C)Temp. Coefficient -10mV/
F
Specifications
Rated Voltage
(C
,
1.75V/cell
,
20hrs)
20
Temperature Effect on Capacity
C.O.V - Cutoff Voltage/cell. The battery is fully charged & being discharged to COV
C.O.V - Cutoff Voltage/cell.
The battery is fully charged & being discharged to COV
ABS
Standby/Float Use
IM
series batteries may be stored for up to 6 months
0
0
at 77 F(25 C) and then a freshening charge is required.
For higher temperatures - time interval will be shorter.
12V
103%
100%
86%
0
0
77
±
5 F (25
±
3 C)
F
2
Layout
104 F (40 C)
0
0
77 F (25 C)
0
0
32 F ( 0 C)
0
0
(25 )
0
C
(25 )
0
C
0
0
Constant Current Discharge (Amperes) at 77 F(25 C)
0
0
Constant Power Discharge (Watts/cell) at 77 F(25 C)
0
0
5

122 F (-15

50 C)
0
0
-4

104 F (-20

40 C)
0
0
5

104 F (-15

40 C)
Discharge
Charge
Storage
Product Data Sheet
IM
Series:
IM-1272
F2

(UT-1272
F2
)

12 Volt, 7.
0

Amp. Hour
F
2
Dimensions
1
F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h
3h
4h
5h
6h
8h 10h 20h
1.85V/cell 17.0 12.5 9.90 8.10 6.12 4.64 3.91 2.90 2.38 1.72 1.36 1.16 0.99 0.780 0.637 0.343
1.80V/cell 18.5 13.2 10.3 8.35 6.28 4.73 3.99 2.95 2.41 1.74 1.38 1.18 1.01 0.790 0.644 0.347
1.75V/cell 19.9 13.8 10.7 8.60 6.43 4.83 4.06 3.00 2.45 1.77 1.40 1.19 1.02 0.800 0.653 0.350
1.70V/cell 21.4 14.4 11.1 8.86 6.57 4.92 4.13 3.05 2.49 1.79 1.42 1.21 1.03 0.809 0.660 0.354
1.67V/cell 22.3 14.8 11.3 9.01 6.67 4.98 4.17 3.08 2.51 1.81 1.43 1.22 1.04 0.816 0.665 0.356
1.60V/cell 24.3 15.7 11.8 9.40 6.87 5.11 4.27 3.14 2.56 1.84 1.46 1.24 1.06 0.829 0.675 0.361
F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h
3h
4h
5h
6h
8h 10h 20h
1.85V/cell 32.3 23.9 19.1 15.6 11.8 9.01 7.61 5.67 4.65 3.37 2.69 2.29 1.96 1.55 1.27 0.686
1.80V/cell 34.8 25.0 19.7 16.0 12.1 9.15 7.73 5.74 4.71 3.42 2.72 2.32 1.99 1.57 1.28 0.693
1.75V/cell 37.4 26.1 20.3 16.4 12.3 9.30 7.84 5.82 4.77 3.46 2.76 2.35 2.01 1.58 1.29 0.700
1.70V/cell 39.9 27.2 20.9 16.8 12.5 9.40 7.95 5.90 4.84 3.50 2.79 2.37 2.03 1.60 1.31 0.707
1.67V/cell 41.4 27.8 21.3 17.1 12.7 9.50 8.02 5.95 4.87 3.53 2.81 2.39 2.05 1.61 1.32 0.712
1.60V/cell 44.7 29.2 22.1 17.6 13.0 9.70 8.17 6.05 4.95 3.59 2.85 2.43 2.08 1.64 1.34 0.722
(20hr,0.350A,1.75V/cell)
(10hr,0.653A,1.75V/cell)
(5hr,1.19A,1.75V/cell)
(3hr,1.77A,1.75V/cell)
(1hr,4.27A,1.60V/cell)
7.00 Ah
6.53 Ah
5.85 Ah
5.30 Ah
4.27 Ah
5.94
±
0.08
2
.
56
±
0.04
3
.
68
±
0.04
3
.
92
±
0.04
1.69
0
.
03
0
.
10
0
.
23
0
.
0
6
0
.
25
5.95 inches ( 151 mm)
2.56 inches ( 65 mm)
3.68 inches (93
.
5 mm
)
3.92 inches (99
.
5 mm) Standby
Float Charging Characteristics
/
Temperature Effectes on Battery

Capacity
Applications

Temperature Effectes on Long Term Float Life
Battery Temperature
Battery Temperature
Stand
ards

General Features

Discharge Characteristics
Sales Offices
Sales: 1.800.233.6261
Website: www.adiglobaldistribution.us
www.
ad
i
g
l
oba
l
d
i
s
t
ri
bu
t
i
o
n.
ca
2
Publication No.: LB-
-PD-ADI-V1.1-202106
IM-1272F2
Curves represent Constant Current draw ( Amp.)
1C curve = 1 x Nominal capacity= 7amp. constant draw 0.05C curve = 0.05 x Nominal capacity = 0.35amp. draw
• Uninterruptable Power Supply (UPS)

• Emergency backup power supply
• All purpose
• Auto control system
• Communication power supply
• Alarm and security system
• DC power supply
• Electric Power System (EPS)
• UL, CE Certified
• Compliance with IEC 60896 standards,
EU Battery Directive
• High quality AGM separator: extend cycle life
and prevent micro short circuit
Special exhaust structure and sealing technology,
safe and reliable, flexible installation, convenient
maintenance

High purity PbCaSn raw material alloy is used for plate
grids, assuring less gassing & low self-discharge rate


0
5 years design life(
77 F
)

• Manufactured in IATF16949,ISO45001,
ISO 9001 and ISO 14001 certified
production facilities
0.05C
0.1C
0.2C
0.4C
0.6C
1C
2C
3C
10
1
2
4
6
20
40
60
2
4
6
8
10
H
Min
8
20
8
9
10
11
12
13


V

12V
Battery
Terminal Voltage(V)
Discharge Time
0
0
Temperature:77 F(25 C)
0
8
16
20
12
24
28
32
36
40
(V)
(XCA)
%
Charge
Volume
Charging
Current
Charging
Voltage
After 100% Discharge
Charge Voltage
(Constant 2.25v/cell)
Charging Current
4
12
13
14
15
11
0.10
0.15
0.20
0.25
0.05
0
0
10
20
30
50
40
60
70
80
90
100
120
110
Charging Time(hours)
After 50% Discharge
Charged Volume
0
0
0.10CA-2.25V/cell Temperature
77 F(25 C)
0.25CA
0.17CA
0.1CA
Capacity

%

20
40
60
80
100
120
-
20
-
10 0 10 20 30 40 50 60
o
C
o
F
-
4
32 5
0
68
14
122
10486
140
Float

life
(
year
)
2
3
4
5
0
20
25
30
35
40
45
50
o
C
o
F
122
104
86
77
95
113
68
1
VdS
Product Data Sheet
IM
Series:
IM-1272F2

(UT-1272F2)

12 Volt, 7.
0

Amp. Hour


Uploaded