WBOX 0E-PIR433 - Installation & Setup Guide - 4/22



Related Products

Taxons
WBOX 0E-PIR433
433 MHz Wireless Pet Immune PIR
List Price:
Our Price: $53.99

Document Transcript


0E-PIR433

433MHz Wireless PIR

(DSC
®
Compatible)



Installation & Setup Guide

FEATURES
The 0E-PIR433 is state-of-the art motion sensor tha
t directly converts the infrared detector signal in
to digital form, for best reliability and stability
.
Additionally, it provides "best-in-class" false ala
rm rejection with excellent intruder detection.


Sensor Initialization

Following power-on, the 0E-PIR433 Motion sensor is
fully operational after a one-minute warm-up.


Walk Test

Note:
The sensor should be tested once per year. The LED
should turn ON (for Alarm) after about two to four
normal steps. Each time the LED turns
ON, wait for it to turn OFF. Then, wait 12 seconds
before continuing the walk test. When there is no m
otion in the monitored area, the LED should remain
OFF. It can be turned off after 5 mins, so it doesn
’t continue to consume power.


Alarm Processing

Dual-element detector fields-of-view alternate betw
een (+) and (-) polarity. HighBar™ - qualified sign
al events are counted as "pulses" exclusively when
polarity alternates. Depending on sensitivity setti
ng, (+,-), (-,+), (+,-,+) or (-,+,-) will cause an
alarm.


Pet Immunity

The sensor is designed to allow the presence of pet
s (60 lbs or lighter) without signaling an alarm. I
t includes a special microelement lens array that
produces much stronger optical signals for humans t
han for pets 60 lbs or lighter. Furthermore, the op
tical sensitivity of each sensor is factory-calibra
ted
to ensure accurate discrimination between humans an
d pets.


Note:
Pets come in many varieties. Some pets (especially
larger ones with
very short hair, even if lighter than 60 lbs) may p
roduce enough infrared
radiation to cause alarms. 0E-PIR433 users are stro
ngly advised to test the
sensor with their own pets, in order to verify that
the sensor will not signal an
alarm when their pets are moving within its fields
of view.


This diagram shows the 0E-PIR433 zones of greatest
human/pet
discrimination. The 0E-PIR433 should be mounted so
that pets will occupy
only the lighter-colored spaces.

7.5’


3’


0 10’ 20’ 30’ 40’



Sensor Optical

View

Pattern

(side

view,

in

feet)

Sensor

Optical

View

Pattern:

(top

view,

in

feet)



0E-PIR433 Wireless PIR Installation Instructions
1. Mounting Location
A. Wall Mounting
1) Sensor base installed flat on vertical wall (+/-
2 degrees)
B. All Mounting
1) Height = 7.5' or 10' above floor of monitored ar
ea
2) Clear line-of-sight from sensor to monitored are
a
Note:
Glass will block the sensor's view.
3) Wall temperature similar to walls/floor of monit
ored area
4) Sensor aimed away from windows and reflected sun
light
5) Sensor aimed away from heaters or heater/cooler
outlets
6)
Sensor aimed away so that it covers likely intruder
paths



B4
A1
B2
B6
!
X
3
0
c
m
room_layout-001-V0
2.
Sensor Disassembly

Insert a screwdriver or thumbnail in the slot at
the bottom of sensor (1) to push inward on cover
latch. Remove cover (2). At the right side of the
sensor base (3), push outward on circuit board
latch. Using the circuit board battery holder as
handle, gently lift circuit board right side and
remove.

3. Base Hole Preparation
Identify necessary holes on diagram;

1) For wall mounting, knock out hole covers.

2) For corner or 45 degree wall mounting,
use a drill to open at least two holes at
base side depressions.


4. Wall Mounting
Use screws to mount on wall or in a corner.


5. Strips Installation
Install the three adhesive strips (3M).

6. Circuit Board and Battery Installation
To replace circuit board:
1) Insert circuit board
right edge into two left-
hand mounting slots in
sensor base.
2) On right-hand side, gently press
circuit
board into place until latch snaps over
circuit board.

3) Insert the CR123 battery in the battery holder.
Be
sure that the (+) is in the correct position
.

7. Operation Programming
Use High-Sensitivity if there is a way for
intruders to pass only a very short distance in
the sensor's view, or if aggressive detection
is required. Otherwise, normal sensitivity is
fine for ordinary applications. Factory-set
positions are shown below in gray.

NOTE:
LED turn on is for test only. Continual
LED use will shorten battery life.
OE-PIR433 Motion

Sensitivity
J4
1-3
2-1
Normal
High
Frequency
S3
ON
OFF

8. Motion Distance Sensitivity
Set J4 (Sensitivity setting) according to need.
Normal sensitivity - detection occurs in 3 to 5
steps.
High sensitivity - detection occurs in 2 to 4 step
s.

9.
Operation Programming
The table below provides possible LED
indications.
0E-PIR433 Motion

Sensor State
LED Display
Warm-up
OFF
Alarm
ON (2 seconds)
Normal
OFF


FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modification
s to the
equipment unless authorized by the Installation Ins
tructions or
User Manual. Unauthorized changes or modifications
could void the
user's authority to operate the equipment
FCC/IC STATEMENT
This device complies with Part 15 of the FCC Rules,
and Industry
Canada’s license-exempt RSSs. Operation is subject
to
the following two conditions: (1) This device may n
ot cause harmful
interference (2) This device must accept any interf
erence
received, including interference that may cause und
esired operation.
Cet appareil est conforme à la partie 15 des règles
de la FCC et
exempt de licence RSS d’Industrie Canada. Son
fonctionnement est soumis aux conditions suivantes:
(1) Cet appareil
ne doit pas causer d' interférences nuisibles. (2)
Cet
appareil doit accepter toute interférence reçue y c
ompris les
interférences causant une réception indésirable.
The product should not be disposed of with other ho
usehold waste.
Check for the nearest authorized collection centers
or authorized
recyclers. The correct disposal of end-of-life equi
pment will help
prevent potential negative consequences for the env
ironment and
human health.


Specifications
IR Sensor: ........................................
...................................................
....................................... Dual Elemen
ts
Optical Fields-of-View ............................
............................. Long-Range 44', Mid-R
ange 36', Short-Range 18'
Events Detection: .................................
.......................................... High Bar
™ false alarm rejection processor
Sensitivity: ......................................
.............................................. Sele
ctable: 2-event or 3-eventPower Supply
Range: ............................................

40' in sensor-facing direction, 40' at 45° angle fr
om sensor-facing direction

Power Supply: .....................................
...................................................
............................ CR123A 3V Battery
Power Supply Current: .............................
...................................................
............................. 22uA (no alarm)
RF Immunity: ......................................
...................................................
....... 20 V/m, 10-1,000MHz. 1 V/m, 1-2
White Light Immunity: .............................
...................................................
.......................................... 6,500 lu
x
Tamper Switch: ....................................
...................................................
......................... Sealed dome-contact
Operating Temperature: ............................
...................................................
.............................. -40 ̊C to +50 ̊C
Pet Immunity: .....................................
...................................................
...................................................
... 60lb
Housing Material: .................................
...................................................
............................... High-impact ABS
Dimensions: .......................................
...................................................
................ 2.9" x 2.4" x 1.7" (H x W x D

Support & Warranty
For online support please go to: www.resideo.com
For warranty information please go to: www.adigloba
l.com

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS
REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.



The HighBar

trademark is used by permission.

All
®
trademarks are the property if their respective own
ers




R800-27522A 4/22 Rev A


ADI Global Distribution
275 Broadhollow Road
Melville, NY 11747
www.adiglobal.com


Uploaded