2GIG FTD100-345 - Installation Guide - 2025
Related Products
Document Transcript
1
Encrypted/Unencrypted Mode Switch
The detector is capable of transmitting signals in encrypted mode or non-
encrypted mode. The mode is set through a switch inside the detector (see
Figure 3). By default, the factory setting is non-Encrypted mode. To change to
Encrypted mode:
1
Remove the top plastic housing and remove the battery from the board.
2
Locate the dip switch (see Figure 3) and note the switch setting: ON
indicates encrypted, and 1 is non-encrypted mode.
3
Move the switch position to ON for encrypted mode.
4
Reinsert the battery and insert the board back into the housing.
If the detector was previously learned into a panel in a different mode,
reset the zone and re-learn in the detector. If applicable, enter the detector
equipment code in sensor zone programming.
Programming
The following steps describe general guidelines for programming (learning) the
detector into the alarm control panel memory. For more details, refer to the
2GIG Panel Installation & Programming Instructions
.
1
Put the panel into sensor Learn mode.
2
Pull battery pull tab or power cycle the detector to start auto learn with a
panel.
Installing the Detector
The 2GIG-FTD100-345 Flood and Temperature Detector can be easily placed
in any location. Place the device in locations that have the potential of water
leaks or flooding. If placed specifically under a potential leak sour
ce, use the
included optional double sided
adhesive tape to secure it in the
desired location (see Figure 4).
Metal contacts (see Figure 5)
on the top and bottom of the
device can detect the presence
of water. Be certain to place the
detector in a manner that does
not impede the detector’s ability
to detect water.
NOTE:
Do not place on a metal
or conductive surface.
For example:
•
Under sink pipes and under
or near your dishwasher
•
Adjacent to water heaters,
toilets, bathtubs, or
showers
•
Near the washer and dryer
PRINTER’S INSTRUCTIONS: 10034955 INSTR, INSTL, 2GIG-FTD100-345, ENGLISH - P/N: 10034955 Rev-C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.5X11”, TOL. +/- 0.125, SCALE: 1:1, FRONT & BACK
FOLDING: FOLD 4X TO FINAL SIZE: 2.125” X 2.750”- FINISH WITH LOGO SHOWING
General Information
The 2GIG-FTD100-345 is a fully supervised, one-way 345 MHz detector. It
will detect wet or dry floor conditions as well as the ambient temperatur
e. The
detector reports wet/dry conditions and when specific temperature thresholds
are exceeded. The detector offers flexible signal transmission options,
supporting both encrypted and non-encrypted modes, and is compatible with
2GIG wireless alarm systems.
Installation & Mounting Guidelines
Flood Conditions
Once the detector contacts detect the presence of water, the integrated
transmitter will immediately send a loop 1 wet alarm transmission to the panel.
The detector will also send a restore (dry) report when the presence of water is
no longer detected after one (1) minute. The detector is capable of detecting
clean or dirty fresh water, salt water, and tap water.
The 2GIG-FTD100-345 utilizes a unique design that can detect leaks dripping
onto its top or if there is water under the device. This dual sensing technology
is perfect for placement under P traps or hoses that may leak, giving a warning
just as the leak starts. If a leak occurs at a different location, it will also be
detected when the water is sensed under the device.
Temperature Conditions
Heat:
•
If the temperature is more than 95° F (35°C) for five (5) minutes, the
sensor will send a loop 2 transmission.
•
If the temperature is less than 95°F (35°C) for five (5) minutes, the sensor
will send a loop 2 clear.
Cold:
•
If the temperature is less than 41°F (5°C) for five (5) minutes, the sensor
will send a loop 1 transmission.
•
In the temperature is more than 41°F (5°C) five (5) minutes, the sensor will
send a loop 1 clear.
Contents
Verify that the package includes the following:
•
1 — 2GIG Flood/Temperature Sensor
•
1 — 3V CR123A Lithium Battery (Installed)
•
1 — Double sided adhesive tape
Replacing Battery
1
Grip the base of the detector case, turn the top cover counter-clockwise
to align the dots, then separate the detector case.
2
Remove old battery and dispose of properly (following state regulations).
3
Install the new battery and close the case.
2GIG-FTD100-345
Wireless Dual Flood-sensing Water and Temperature Detector
Figure 1
Temperature/
Flood Detector Contents
DETECT
OR
DOUBLE-SIDED
ADHESIVE
TAPE
LITHIUM BA
TTER
Y
LITHIUM
ALIGN DOTS
Figure 2
Opening the Detector Case
BATTERY TERMINAL
NEGATIVE (-)
BATTERY TERMINAL
POSITIVE (+)
ENCRYPTED/
NON-ENCRYPTED
SWITCH
Figure 3
Installing New Battery
DETECTOR
WATER
Figure 4
Suggested
Installation Locations
MET
AL CONT
ACTS
(TOP)
MET
AL CONT
ACTS
(BOTTOM)
Figure 5
Flood Detector Contacts 2
Regulatory Information
We, Nice North America LLC of 5919 Sea Otter Place STE 100, Carlsbad, CA 92010, declare under our
sole responsibility that the device, 2GIG-FTD100-345 complies with Part 15 of the FCC rules.
FCC & IC Notice
This device complies with Part 15 of the FCC Rules and Industry Canada license exempt standard(s).
Operation is subject to the following two conditions:
(3)
This device may not cause harmful interference, and
(4)
This device must accept any interference received, including interference received that may
cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
•
Consult the dealer or an experienced radio/TV technician to help.
FCC
Federal Communication Commission (FCC) Radiation Exposure Statement:
When using the product, maintain a distance of 20cm from the body to ensure compliance with RF
exposure requirements.
IC
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.
WARNING
:
Changes or modifications not expressly approved by the manufacturer could void the
user’s authority to operate the equipment.
* For more warranty and compliance information, visit out website (
www.2gig.com
)
Limited Warranty
This Nice North America LLC product is warranted against defects in material and workmanship for two
(2) years. This warranty extends only to wholesale customers who buy direct from Nice North America
LLC or through Nice North America LLC’s normal distribution channels. Nice North America LLC does not
warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature
of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of Nice North America LLC for consequential damages
arising out of or in connection with use or performance of this product or other indirect damages with
respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied
warranties for functionality, are valid only until the warranty expires. This Nice North America LLC
Warranty is in lieu of all other warranties expressed or implied.
10034955 Rev-C
5919 Sea Otter Place, Suite 100
Carlsbad, CA 92010 USA
For technical support in the USA and Canada:
855-2GIG-TECH (855-244-4832)
Email:
2GIG.Linear@niceforyou.com
Visit
Niceforyou.com
for technical support hours of operation.
For technical support outside of the USA and Canada:
Contact your regional distributor.
Visit
www.2gig.com/dealers
for a list of distributors in your region.
Niceforyou.com
©2025 Nice North America LLC. 2GIG is a registered
trademark of Nice North America LLC. All rights reserved.
Securing the Detector
In areas where the detector could be accidentally moved, secure the detector
in place with the provided double-sided adhesive tape.
NOTE:
Make sure you secure the tape without covering any of the three metal
contacts.
Specifications
Operating Temperature
32°to 104° F (0° to 40° C)
Operating Rel. Humidity
5 to 95%, non-condensing
Operating Frequency
345 MHz
Battery Type
CR123A 3V lithium battery
Projected Battery Life
5 years
Supervisory Interval
70 minutes
Panel Programming Sensor
Loop
Loop 1: Water
Loop 2: Heat
Loop 3: Cold
Equipment Code
2065 (Encrypted): 1065 (Non-encrypted)
Figure 6
Detector Double-Sided Adhesive Tape Application
DOUBLE-SIDED
ADHESIVE
TAPE