Alarm.com Emergency Call Button w/Qolsys 319.5 MHz Transmitter - Install Guide



Related Products

Taxons
Alarm.com Emergency Call Button
w/ 319.5 MHz Transmitter

Document Transcript

Emergency Call Button with Qolsys Transmitter
Overview
Emergency Call Buttons can be placed in fall risk areas such as near bathtubs and stairs.
Specifications
SKU
ADC-EPB-BC2.1-GE
Enclosure
4.75 in. x 2.25 in. (Diameter x Depth) Black, ABS plastic
base with slip-resistant feet and 3 x AAA battery housing
for optional audible message on button press Red, ABS
plastic, spring-loaded push button
Electronic Signaling
Battery-powered filter circuit with integrated 319.5
MHz
(crystal-controlled) Qolsys-compatible transmitter with
64-minute supervisory interval
Sensing Interface
Filtered, normally open (i.e. when not pressed),
momentary contact switch
Battery Life
Replaceable 3x AAA battery: 2+ years
Programming
Note
:
If enrolling the device locally at the panel, the sensor can be tampered by pressing the button within the first two
seconds that the on/off switch is set to the
On
position.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Emergency_Call_Button/Emergency_Call...
Updated: Mon, 23 Sep 2019 21:15:56 GMT
1 To program the Emergency Call Button using the Partner Portal:
1.
Log into the Partner Portal.
2.
Find the customer account.
3.
Click
Equipment
.
4.
Click
Sensors
.
5.
In
Sensor Management
, click
Add a Sensor
.
6.
For
Sensor ID
, enter an unused ID.
7.
For
Sensor Type
, select
Auxiliary Pendant
.
8.
For
Group
, select
4
.
9.
For
Sensor Name
, select
Panic Button
.
10.
Enter the six-digit DL code found
on the bottom of the sensor.
11.
Click
Add Sensor
.
To program the Emergency Call Button using the MobileTech app:
1.
Log into the MobileTech app.
2.
Find the customer account.
3.
Tap
Equipment
.
4.
Tap
Sensors
.
5.
Tap to expand
Sensor Actions
.
6.
Tap
Add a Sensor
.
7.
For
Sensor ID
, enter an unused ID.
8.
For
Sensor Type
, select
Auxiliary Pendant
.
9.
For
Group
, select
4
.
10.
For
Sensor Name
, select
Panic Button
.
11.
Enter the six-digit DL code found
on the bottom of the sensor.
12.
Tap
Add Sensor
.
Installation
1.
Locate the sensor within 100 feet of the base station.
2.
Verify that the on/off switch on the base of the button is set to the
On
position.
Caution
: The device may signal a tamper if the button is pressed within the first two seconds after the on/off
switch is set to the
On
position.
3.
The sensor can be mounted using the included mounting plate and mounting hardware, or simply place the sensor
on a flat surface in a visible location.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Emergency_Call_Button/Emergency_Call...
Updated: Mon, 23 Sep 2019 21:15:56 GMT
2 Use
Press and hold the button for one second.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Emergency_Call_Button/Emergency_Call...
Updated: Mon, 23 Sep 2019 21:15:56 GMT
3


Uploaded