Document Transcript

Classification:
"Lithium Coin"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Nominal Voltage:
3.0 Volts
Typical Capacity:
130 mAh (to 2.0 volts)
(Rated at 15K ohms at 21°C)
Typical Weight:
1.8 grams (0.06 oz.)
Typical Volume:
0.5 cubic centimeters (0.03 cubic inch)
Max Rev Charge:
1 microampere
Energy Density:
209 milliwatt hr/g, 754 milliwatt hr/cc
Typical Li Content:
0.036 grams (0.0013 oz.)
Operating Temp:
-30C to 60C
Self Discharge:
~1% / year
Load
Cutoff
2.0V
(ohms)
(hours)
15,000
684
Bkgnd Drain:
Continuous
15K ohms
0.19 mA @2.9V
Pulse Drain:
2 seconds X 12 times/day
400 ohms
6.8 mA @2.7V
Lithium Coin
ENERGIZER CR1632
Simulated Application test
Specifications
mm (inches)
Industry Standard Dimensions
Typical Performance at 21°C (70°F)
Typical Drains:
Safety:
(1) KEEP OUT OF REACH OF CHILDREN.
Swallowing may lead to
serious injury or death in as little as 2 hours due to chemical burns and
potential perforation of the esophagus.
Immediately see doctor; have
doctor phone (800) 498-8666.
(2) Battery compartment design
. To prevent children from removing
batteries, battery compartments should be designed with one of the
following methods: a) a tool such as screwdriver or coin is required to open
battery compartment or b) the battery compartment door/cover requires
the application of a minimum of two independent and simultaneous
movements of the securing mechanism to open by hand. Screws should
remain captive with the battery door or cover.
Continuous
Contents herein do not constitute a warranty and are for reference only.
at 2.9V
(mA)
0.19
Pulse Test at 21°C (70°F)
Typical Discharge Characteristics
Internal Resistance Characteristics
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
Schedule:
PRODUCT DATASHEET



1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
200
400
600
800
Voltage, CCV

Service, Hours


Load:
15
K ohms
-

Continuous

Typical Drain @
2.9
V:
0.19
mA

15
30
45
60
75
90
105
120
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0
30
60
90
120
150
IR, ohms

Voltage, CCV

Capacity, mAh

IR

Pulse

Bkgnd


3.20 (0.126)
3.00 (0.118)
16.00 (0.630)
15.75 (0.620)




Form No. 1632NA0618