Honeywell DT8035V - Quick Installation Guide Dated 5/2020, Rev. C



Related Products

Honeywell DT8035V - Wired Dual Tec Motion Sensor
Honeywell DT8035V
Wired Dual Tec Motion Sensor
List Price: $92.00
Our Price: $66.99

Related Categories


Document Transcript


DT8035V

Dual Technology Motion Sensor

Détecteur de mouvement
à double technologie

Sensor de m
ovimiento
de tecnología dual

Sensor de
m
ovimento

de tecnologia dupla


Quick
Installation Guide

Guide d’installation rapide

Guía
Rápida
de instalación

Guia
rápido
de instalação









- 2 -






1.

Close the sensor and apply power. Initialization is complete when
the LED stops flashing slowly (about 30 seconds).

2. Turn t
he microwave sensitivity counterclockwise to reduce the
microwave range (minimum = 16.4’ / 5m) and close the sensor.

3. Walk through the detection area and observe the LED.

4. Adjust the microwave range as necessary to meet installation
requirements.

LED

Power U
p

Walk Test

Normal

Fault

Red

Slow

Blink

ON

Alarm

ON

Alarm

Fast

Blink

Yellow

OFF
ON

Microwave

ON

Microwave

OFF

Green
OFF

ON

PIR

ON

PIR

OFF


Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters
normal
operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature (see Walk
Test Reset above).

Note
: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch
setting.






- 3 -
SPECIFICATIONS

Operating Temperature
:
................................
....................................................................................................................
14° to 131°
F / -
10° to 55°C

Relative Humidity
: ................................
..................................................................................................
5 to 93
% (UL tested at 93%)
; non-
condensing

Dimensions:
................................
........................................................................................................................
3.86 x 2.24 x 1.69in / 98
x 57 x
43mm

Tamper
:
....................................................................................................................................................................
Cover and Wall Tamper Protection

Electrical Power:
..........................................................................................................................................
15mA (normal use); 17mA (maximum use)

Microwave Frequency:
................................................................................................................................................................................
10.525GHz

Range:
................................
........................................................................................................
Cone shape detection area of 40 x 56ft (
12.2 x 17.1m)

Pet Immunity:
...................................................................................................................................................................................
Up to 100lb / 45k
g)


TROUBLESHOOTING



TROUBLE*


NORMAL

Self
-
Test Failure
1

Alarm Relay

Closed

Ope
n

Red LED

Off

Flashing

*TROUBLE CONDITIONS

1
Self
-Test Failure conditions:

• Microwave supervision failure:
The sensor is operating in PIR mode only.

• PIR self
-test failure:
The sensor is disabled.

• Temperature compensation failure: The temp
erature compensation is disabled.

Depending on the Trouble condition, take the following corrective actions:

• Verify the power supply is sufficient (at least 9V at the sensor).

• Cycle power to the sensor.

• Walk test the sensor.



If th
e Trouble condition does not clear, replace the sensor.


APPROVAL
LISTINGS


FCC part 15, Class B verified


IC ICES
-003, Class B verified


UL 639


ULC S306
-03


SIA-
PIR
-01 Passive Infrared detector standard features for false alarm immunity.

Product must be
tested at least once each year / Le fonctionnement du produit doit être vérifié au moins une fois par année /
El producto debe ser probado al menos una vez al año /
O produto deve ser testado pelo menos uma vez por ano
All wiring must be in accordance wi
th: the National Electrical Code (ANSI/NFPA70); the Canadian Electrical Code, Part I (where applicable);
UL681, Standard for Installation and Classification of Burglar and Holdup Alarm Systems; ULC
-S302, Standard for Installation and
Classification of Burg
lar Alarm Systems for Financial and Commercial Premises, Safes and Vaults; ULC
-S310, Standard for Installation and
Classification of Residential Burglar Alarm Systems; local codes and the authorities having jurisdiction.

The products are intended to be pow
ered by a power
-limited output of a UL/CUL Listed Burglar Alarm control unit, or via a Listed UL603/ULC
-
S318 power
-limited power supply that provides 4 hours of standby power
.
The sensor must be mounted indoors, within the protected premises, and on a wooden stud, solid wood or with a robust wall anchor.

UL Notes
: All interconnecting devices must be UL listed. The
pet immunity feature has not been evaluated by UL.


FEDERAL COMMUNICATIONS COMMISSION STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.
Unauthorized changes or modifications could void the user's authority to operate the equipment.

CLASS B DIGITAL DEVICE STATEMENT

This equipment has been tested to F
CC requirements and has been found acceptable for use. The FCC requires the following statement for your
information:

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordanc
e with the manufacturer's
instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the
limits for a Class B
computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such
interference in a residential installation. However, there is no guarantee that interference will not occur in a particular i
nstallation. If this equipment does
cause interference to radio or television recep
tion, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

• Reorient the receiving antenna until interference is reduced or eliminated.

• Move the radio or television receiver away from the receiver/control.

• Move the antenna leads away from any wire runs to the receiver/control.

• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.

• Consult the dealer or an experienced radio/TV technician for help.

INDUSTRY CANADA CLASS B STATEMENT

This Class B digital apparatus complies with Canadian ICES
-003.

Cet appareil numérique de la classe B est conforme à la norme NMB
-003 du Canada.

FCC/IC NOTICE:
This device complies with Part 15 of the FCC Rules, and RSS
-210 of IC. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference (2) This device must accept any interference received,
including interference that may cause undesired
operation.


Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS
-210 des Industries Canada. Son fonctionnement est soumis aux conditions
suivantes: (1) Cet appareil ne doit pas causer d' in
terférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.




TO THE INSTALLER

Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous
satisfactory operation of any alarm system. The installer should assume the responsibility of developing and offering a regu
lar
maintenance program to the user, as well as acquainting the user with the proper operation and limitations of the alarm system and
its component parts. Recommendations must be included for a specific program of frequent testing (at least weekly) to insure the
system’s operation at all times.


REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL
WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING
LIMITATIONS OF THE ENTIRE ALARM SYSTEM
.

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center
Drive., Melville
, NY 11747, Ph: 516-
577-
2000


The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The
correct disposal of end-
of-life equipment will help prevent potential negative
consequences for the environment and human health.

Any attempt to reverse-
engineer this device by decoding proprietary protocols, de-
compiling firmware, or any similar actions is strictly prohibited.



To protect the environment, a detailed installation g
uide is available on the Resideo website –
Please consider before printing the document!




SUPPORT & WARRANTY INFORMATION
For the latest documentation, support, and warranty information please go to:

www.resideo.com


































This product manufactured by Resideo Technologies
, Inc.
and its affiliates






2 Corporate Center Drive, Suite 100

P.O. Box 9040, Melville, NY 11747


2021
Resideo Technologies, Inc.

www.resideo.com



ÊR800
-26065C1Š

R800-26065C
5/20 Rev. C


Uploaded