Programming Guide for Vizia Dimmers and Quiet Fan Speed Control



Related Products

Leviton VRF01-1LZ - Z-Wave Fan Controller
Leviton VRF01-1LZ
Z-Wave Fan Controller

Related Categories


Document Transcript

1. TECHNICAL APPLICATION NOTEProgramming Guide for Vizia + Dimmersand Quiet Fan Speed ControlVizia+™ProgrammingGuideDim/Bright BarVIZIA + DIMMERS PROVIDE THE FOLLOWINGADVANCED PROGRAMMING FEATURES:I. DIMMER PROGRAMMINGSECTION A• Energy Save - Set the maximum brightness levelfor energy savings• Minimum Brightness Level – Set the minimumdimming level• Preset ON Level – Set the turn on brightness levelregardless of the previous set light level (formerly Dim Lock)• Almost OFF Level – Sets the brightness level the device willdim the lights to when the push pad is pressed to turn OFF.In this mode the lights will always remain ON at a reducedenergy consumption level.• ON Fade Rate – Set the amount of time in seconds it takesthe lights to turn ON to maximum brightness• OFF Fade Rate – Set the amount of time in seconds it takesthe lights to turn OFF from maximum brightness• LED Options – Set the time period in seconds the LocatorLED and Brightness Display will stay lit before extinguishing• Restore Defaults – Restores the factory default settingsMODE DESCRIPTION RANGE DEFAULTA-1 Energy Save 100% - 75% 100%A-2 Minimum Brightness Level 1% - 50% LED 2A-3 Preset On Level 1% - 100%, not active Not activeA-4 Almost OFF Level 1% - 50% Not activeB-1 On Fade Rate 0s – 25s 0.5 secondsB-2 OFF Fade Rate 0s – 25s 0.5 secondsB-3 LED Options Active, turn off after 5s ActiveC Restore DefaultsADVANCED FEATURES SUMMARYLeviton Mfg. Co., Inc.59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Locator LightPush PadLED Brightness DisplaySECTION BLeftmost LED = LED 1Rightmost LED = LED 7APPLICABLE CAT. NUMBERSVPI06, VPM06, VPM10, VPE04, VPE06, VPX10, VPZX12-7, VPH08, VPH06-7VPI06
2. Vizia+™ProgrammingGuideLeviton Mfg. Co., Inc.59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Section CDimmer ProgrammingVPI06, VPM06, VPM10, VPE04, VPE06, VPX10, VPX12,VPH08, VZH06NOTES:• Have a flashlight handy if this dimmer controlsthe only light source in the room• The device will exit programming mode after3 minutes of inactivity• Pressing the Push Pad at any time duringprogramming will advance the device to thenext programming mode.Program Mode ATo enter Program Mode A:Push and hold the Push Pad and then the right half ofthe DIM/BRIGHT Bar (^) for 5 seconds until the LocatorLED and leftmost LED (LED 1) begin to blink.A-1) Upon releasing the Push Pad and the righthalf of the DIM/BRIGHT Bar (^) , the LocatorLED will continue to blink once per second andthe rightmost LED will illuminate to display thedevice is in Program Mode A-1, Energy Save.To change the Energy Save Level, use theDIM/BRIGHT Bar to move the corresponding LEDto the desired discrete preset level according toChart A. By tapping the Push Pad this settingwill automatically be saved and the device willadvance to the next programming mode, A-2.A-2) The Locator LED will blink 2 times per second toindicate the device is in Program Mode A-2,Minimum Brightness Level. To change theMinimum Brightness Level from 1-50%, use theDIM/BRIGHT Bar. The light output will reflect theminimum brightness level selected. By tappingthe Push Pad this setting will automatically besaved and the device will advance to the nextprogramming mode, A-3.A-3) The Locator LED will blink 3 times per second toindicate Program Mode A-3, Preset ON Level. Tochange the current Preset ON Level from 1-100%,use the DIM/BRIGHT Bar. If this feature is notdesired, press and hold the left half of theDIM/BRIGHT Bar ( ) until no LED is lit (defaultsetting). By tapping the Push Pad this setting willautomatically be saved and the device willadvance to the next programming mode, A-4.A-4) The Locator LED will blink 4 times per second toindicate Program Mode A-4, Almost OFF Level.To change the current Almost OFF Level, use theDIM/BRIGHT Bar to adjust the preset light level.If this feature is not desired, press and hold theright half of the DIM/BRIGHT Bar (^) until noLED is lit (default setting). Almost OFF can beoverridden by pressing and holding the left half ofthe DIM/BRIGHT Bar ( ) until the lights turn off.By tapping the Push Pad this setting willautomatically be saved and the device willexit Programming Mode A.Note: When Almost OFF Level is set the LED Locatorwill be illuminated when the dimmer is in the AlmostOFF state, even though the light remains on at areduced energy consumption level.Program Mode BTo enter Program Mode B:Push and hold the Push Pad and then the left half of theDIM/BRIGHT Bar ( ) for 5 seconds until the Locator LEDand rightmost LED (LED 7) begin to blink.B-1) Upon releasing the Push Pad, the Locator LED willcontinue to blink once per second indicating thedimmer is in Program Mode B-1, ON Fade Rate. Tochange the ON Fade Rate, use the DIM/BRIGHT Barto move the LED to the desired preset level accordingto Chart B. By tapping the Push Pad this setting willautomatically be saved and the device will advanceto the next programming mode, B-2.B-2) The Locator LED will blink 2 times per second toindicate Program Mode B-2, OFF Fade Rate. Tochange the OFF Fade Rate, use the DIM/BRIGHT Barto move the LED to the desired preset level accordingto the Chart B. By tapping the Push Pad this settingwill automatically be saved and the device willadvance to the next programming mode, B-3.^^^LED MAXIMUM BRIGHTNESS ENERGY SAVINGSLED 1 75% 34% savingsLED 2 80% 29% savingsLED 3 85% 24% savingsLED 4 90% 16% savingsLED 5 95% 8% savingsLED 6 97% 5% savingsLED 7 100% (full bright) 0 % Savings(Default)ADVANCED FEATURES SUMMARYCHART ALED 1 0 seconds (instant) 0 seconds (instant)LED 2 (Default) 0.5 seconds 0.5 secondsLED 3 1.5 seconds 1.5 secondsLED 4 3 seconds 3 secondsLED 5 6 seconds 6 secondsLED 6 10 seconds 10 secondsLED 7 25 seconds 25 secondsLED FADE ON FADE OFFCHART B
3. B-3) The Locator LED will blink 3 times per secondto indicate Program Mode B-3, LED Options.To change the LED Options settings, use theDIM/BRIGHT Bar to move the LED to the desiredpreset setting according to the chart below.By tapping the Push Pad this setting willautomatically be saved and the device willexit Programming Mode BProgram Mode CTo enter Program Mode C:Engage the air-gap switch by gently pressing the top ofthe Push Pad until the bottom liftscompletely out of the frame and a click is heard.All LEDs will extinguish.C) Press Push Pad back into the frame and hold for7 seconds until and the LED Brightness Displaystarts bi-directional strobing to indicate ProgramMode C, Restore Default. To Restore Defaultsettings, release the Push Pad. This will savedefaults settings and exit Programming Mode C.Leviton Mfg. Co., Inc.59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Vizia+™ProgrammingGuideLED 1 Active ActiveLED 2 Active Turns off 5 seconds after useLED 3 Turns off 5 seconds after use ActiveLED 4 Turns off 5 seconds after use Turns off 5 seconds after useLED 5 N/A N/ALED 6 N/A N/ALED 7 N/A N/ALED LOCATOR LED TIMEOUT LED BRIGHTNESSDISPLAY OPTIONSLED OPTIONS CHARTDefault ActiveFirst toggle Turns off 5 seconds after useLOCATOR LED LOCATOR LED OPTION SETTINGSWITCH PROGRAMMING• LED Option - Sets the Locator LED timeout to5 seconds after use.NOTE: The switch will exit program mode after3 minutes of inactivityProgram ModeTo enter Program Mode:Push and hold the Push Pad for 10 seconds until theLocator LED begins to blink. Upon releasing the PushPad, the LED Option will automatically be changed.Locator LightPush PadVPS15
4. Leviton S. de R.L. de C.V.Lago Tana 43, Mexico DF, Mexico CP 11290 • Tel. (+52) 55-5082-1040 • FAX: (+52) 5386-1797 • www.leviton.com.mxG-7904/J7-tpLeviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 • Telephone: 1-800-469-7890 • FAX: 1-800-563-1853Leviton Manufacturing Co., Inc.59-25 Little Neck Parkway, Little Neck, NY 11362-2591Telephone: 1-800-323-8920 • FAX: 1-800-832-9538 • Tech Line (8:30AM-7:30PM E.S.T. Monday-Friday): 1-800-824-3005Visit our Website at: www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Vizia+™ProgrammingGuideLED 1 (Default) Active ActiveLED 3 Active Turns off 5 secondsafter useLED 7 Turns off 5 seconds Turns off 5 secondsafter use after useLED LED LOCATOR LED BRIGHTNESSTIMEOUT DISPLAY TIMEOUTFAN SPEED CONTROL PROGRAMMINGVPF01• Preset ON Level – Set the turn on fan speedregardless of the previous set level• LED Options – Set the time period in secondsthe Locator LED and Fan Speed will stay litbefore extinguishing• Restore Defaults – Restores the factory defaultsettings (including device load ON at maximum level)NOTES:• The device will exit program mode after 3 minutesof inactivity• Pressing the Push Pad at any time duringprogramming will advance the device tothe next programming mode.Program Mode ATo enter Program Mode A:Push and hold the Push Pad and then the right half ofthe FAN SPEED Bar (^) for 5 seconds until the Locator LEDand leftmost LED (LED 1) begin to blink. The Locator LEDwill blink once per second to indicate Program Mode A,Preset ON Level. To change the current Preset ONLevel from HIGH (LED 7), MEDIUM (LED 4) or LOW (LED 1),use the FAN SPEED Bar. If this feature is not desired,press and hold the left half of the FAN SPEED Bar ( )until no LED is lit (default setting). By tapping the PushPad this setting will automatically be saved and thedevice will exit Programming Mode A.Program Mode BTo enter Program Mode B:Push and hold the Push Pad and then the left half ofthe FAN SPEED Bar ( ) until the rightmost LED (LED 7)begins to blink. The Locator LED will blink 2 times persecond to indicate Program Mode B, LED OptionsMode. To change the LED Options settings, use theFAN SPEED Bar to move the LED to the desired presetsetting according to the chart below. By tapping thePush Pad this setting will automatically be saved andthe device will exit Programming Mode B.Program Mode CTo enter Program Mode C:Engage the air-gap switch by gently pressing the top ofthe Push Pad until the bottom lifts completely out of theframe and a click is heard. All LEDs will extinguish.Press Push Pad back into the frame and hold Push Padfor 7 seconds until the LED Brightness Display startsbi-directional strobing to indicate Program Mode C,Restore Default. Releasing the Push Pad will RestoreDefault settings and exit programming mode.^^Fan Speed BarLocator LightPush PadLED Brightness DisplayMODE DESCRIPTION RANGE DEFAULTA Preset On Level 1% - 100%, not active Not activeB LED Options Active, turn off after 5s ActiveC Restore DefaultsADVANCED FEATURES SUMMARYVizia +™ is a trademark of Leviton Manufacturing Co., Inc.Covered by one or more U.S. and Foreign Patents and patents pending.