4232CBM

Connected Building

Module

Installation and Setup Guide


About the 4232CBM
The 4232CBM Connected Building Module is intended t
o
provide connection between compatible Resideo contr
ol
panels and supported third-party software and hardw
are
products. It provides an interface between the cont
rol panel’s
ECP bus and external equipment with either RS422 or

RS232 interfaces. The connection and configuration
of this
device is application-specific. Please refer to the

documentation for your external equipment for infor
mation on
which connection method to use, and how to configur
e the
external device to communicate properly with the 42
32CBM.
NOTE:
The connected building features offered by the
4232CBM are not evaluated by ETL or UL.
Compatible Controls
Con
tr
ol

Firmware Level

VISTA-15P, VISTA-15PSIA
VISTA-20P, VISTA-20PSIA
V9.1 or higher
VISTA-21iP, VISTA-21iPSIA

V3.13 or higher
VISTA-128BPT,
VISTA-128BPTSIA
All versions

The 4232CBM module connects to the control panel vi
a the
panel’s ECP terminals, and connects to the external

computer or other equipment via either RS422 or RS2
32
connections, according to the application.
The module is powered via the control panel’s ECP +
12VDC
connection.
Wiring the Module
Refer to the diagram below for connections.
Mounting the Module
Mount the module inside the control panel cabinet u
sing
double-sided tape (supplied). Make sure the solder
connections on the bottom of the PC board do not to
uch the
cabinet.

LED Indications
Four green LEDs indicate the following conditions:

LED
Condition
Meaning
external
device
On
message waiting for the
external device
Flashing
check connection to the

external device
Panel
On or Blink
keypad data waiting for the
external device
Power
Slow Blink
power on, normal operation
Flashing
power on, not configured
Off
power off
Data
Blink
receiving data from the external
device
Specifications
Board Dimensions
3.75” W x 2.5” L x 0.875” D
Current Drain
50mA nominal; 75mA max
ECP Input Voltage
8-14VDC
Wire Run Length
RS232 Connection: 50 ft max with
24 AWG twisted pair wire
RS422 Connection: 1000 ft max
with 24 AWG twisted pair wire
ECP Connection: 900 ft max home
run with 22 AWG unshielded wire
Temperature
32°F (0°C) to 140°F (60°C)


1.
4232CBM to External Equipment Connection
: For RS232 applications, connect the three RS232 l
ines
(GND, Tx and Rx) to the external equipment. For RS4
22 applications, connect the four RS422 lines (Tx+/
-
and Rx +/-) to the appropriate points on the extern
al equipment.


4232CBM-001-V0
CONTROL 4232CBM
CONTROL PANEL
ECP CONNECTION
RS422
CONNECTIONS
9-PIN
CONN.
RS232
CONNECTIONS
4232CBM PC BOARD
DATA (RECEIVING)
(MESSAGE WAITING)
PANEL (KEYPAD DATA)
POWER
LED INDICATORS
STANDARD
9-PIN
SERIAL
CONNECTOR
NOT USED
DATA OUT
GND
DATA IN
12VDC
4-WIRE
HARNESS
TX
TX
RX
RX
RX (YELLOW)
GND (BLACK)
TX (GREEN)
12VDC (RED)

120
NOTE:
IF WIRE RUN TO RS422 DEVICE EXCEEDS 100 FT, INSTALL
120 OHM RESISTOR BETWEEN RX AND RX TERMINALS ON
THE 4232CBM.
RESISTOR
5(GND)
3(TX)
2(RX)
GND
RX
TX


NOTES:
A. The connections shown above are used for most ap
plications where the external equipment has a male
DE-9 connector (for
example, PCs and most home automation equipment).
B. For RS422 applications, refer to the documentati
on for your external equipment.
2.
4232CBM to Control Panel Connection:
Plug the connector of the 4-wire harness (supplied
) into the 4-pin ECP
connector on the 4232CBM board. Connect the flying
leads to the appropriate control panel ECP terminal
s as shown.
1
2
3
ZONE 1
AC
(YEL) DATA OUT TO DEVICE
(GRN) DATA IN FROM DEVICE
(RED) 12VDC
(BLK) GROUND
4232CBM-002-V0
4
5
7
8
9
6
CONNECT
4232CBM TO
CONTROL'S
ECP
TERMINALS
4 7


VISTA Residential Series Controls ECP Connection
(ex. VISTA-15P, VISTA-20P, VISTA-21iP)
AC
(YEL) DATA OUT TO DEVICE
(GRN) DATA IN FROM DEVICE
(RED) 12VDC
(BLK) GROUND
4232CBM-003-V0
CONNECT
4232CBM TO
CONTROL'S
ECP
TERMINALS
6 9
1
2
3
4
5
7
8
9
10
6


VISTA Commercial Series Controls ECP Connection
(ex. VISTA-128BPT, VISTA-128BPTSIA)
Programming to Enable the Module
The 4232CBM uses up to three ECP device addresses;
one address for the RIS (Remote Interactive Service
) device and
either one or two emulated keypad addresses, depend
ing on the application.
Refer to the documentation for your external equipm
ent to determine if you also need to enable one or
more keypad
addresses. These addresses should be enabled as AUI
devices.
To enable RIS functionality in the control panel, f
ollow these programming steps:

Control

Programming Notes for Enabling
Remote

Interactive S
ervice (RIS)

VISTA-15P
VISTA-15PSIA
VISTA-20P
VISTA-20PSIA
VISTA-21iP
VISTA-21iPSIA


Field

∗∗

91 Option Selection

Enable RIS by programming data field

91 Option Selection, entry 2 as follows:

∗∗

91

Option Selection (SIA Panels: Options/Call Waiting
Disable & RIS Enable)



x 2
(x = see control’s programming instructions for app
ropriate values)


1
2

Options RIS Enable (SIA Panels: Call Waiting Disa
ble/RIS Enable)


For Entry 2, enter “2” (SIA Panels: enter “2,” or
enter “3” if Call Waiting Disable also
desired).

Field

∗∗

189 Touch Screen Device Enable
If the application requires emulation of a graphic
al keypad, then enable a virtual AUI device address

for Remote Services by programming data field

189 Touch Screen Device Enable as follows:

∗∗

189

AUI Device Enables (for Touchscreen Style Touchpads
)



x

x x x

(x = partition number for installed AUI devices)

AUI 1
AUI 2 AUI 3 AUI 4



Enable Remote Services by entering 5, 6, or 7 (depe
nding on the partition in which the
remote services device is located) in an unused AUI
location.

(5 = remote services partition 1; 6 = remote serv.
partition 2; 7 = remote serv. partition 3)


Device Addresses: AUI 1 = addr. 1; AUI 2 = addr. 2;
AUI 3 = addr. 5; AUI 4 = addr. 6

NOTE:
When using the 4232CBM, the selected AUI device ad
dress serves as a virtual device used
for Remote Services purposes that allows the contro
l to receive status information from the external
equipment. Therefore, the selected address cannot b
e used for an actual AUI Touchscreen.

VISTA-128BPT
VISTA-128BPTSIA
In #93 Device Programming, two device addresses mus
t be programmed to enable remote interactive
services. Set one of these device addresses to type
12 (RIS), which enables RIS operation. Set the
other device address to type 01 (alpha keypad), whi
ch enables a virtual keypad that is also needed for

RIS operation.
Note:
The default ECP address for RIS functionality is 2
5. Although some applications may allow you
to change this setting from the external equipment,
using the default address is recommended.

REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE C
ONTROL WITH WHICH THIS DEVICE IS USED FOR
WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE
SYSTEM.

Responsible Party / Issuer of Supplier’s Declaratio
n of Conformity: Ademco Inc., a subsidiary of Resid
eo Technologies, Inc., 2 Corporate
Center Drive., Melville, NY 11747, Ph: 516-577-2000
.


The product should not be disposed of with other ho
usehold waste. Check for the nearest authorized col
lection centers or authorized recyclers.
The correct disposal of end-of-life equipment will
help prevent potential negative consequences for th
e environment and human health.
Any attempt to reverse-engineer this device by deco
ding proprietary protocols, de-compiling firmware,
or any similar actions is strictly
prohibited.
T
his product manufactured by Resideo Technologies, I
nc. and its affiliates



800-05295-1C 6/11 Rev. C