Yale Real Living YRC226 - Install Guide



Related Products

Taxons
Yale YRC226
Assure Lock Interconnected Z-Wave Plus Lockset with Touchscreen Keypad
List Price: $754.00
Our Price: $526.99

Related Categories


Document Transcript

1
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Retrofitting or modifying this product may impact fire rating, safety features and warranty.
Consult with code specifications to ensure compliance with all codes and ratings.
Yale Assure Lock
®®
Installation and Programming Instructions
(YRC226/YRC426/YRC620)
Electronic Interconnected Touchscreen
®
Network Module
(Optional - Not
available on
YRC620)
Before you begin
for step-by-step installation
instructions & to register
your product
DOWNLOAD
THE BILT APP
4" Touchscreen Shown - 5.5" Available
Inside
of Door
Outside
of Door 2
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Before You Begin
1-3/8" (35mm) Min to
1-3/4" (44.5mm) Max
4-1/2"
(114)
Min
x1
x2
x8
Network Module
(Optional - Not
available on
YRC620)
3/32"
1/8"
Template
x2
x2
x2
#2
1/8"
2-1/8"
1
1" 3
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Mark Door Reference Lines
C
L
R
E
M
O
V
E
Template
EXISTING
2-3/8" or 2-3/4"
Backset 4
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
1
Preparing Door
(if necessary)
!
Drill holes 1/2 way thru
door then complete
from other side to
prevent splitting.
Ø2-1/8"
2-3/8"
or
2-3/4"
Ø1"
Template
4"
or
5.5" 5
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
2
Installing Strike Plates
Door
Frame
Inside
of Door
Frame
1" Dia. x
1"Deep
1" Dia. x
1/2"Deep
Frame
7-16 / 8-32 x 1" UNCWS
x4 Left Hand “
”, Hinges Left.
LH
Open Inward.
Left Hand Reverse "
", Hinges Left.
LHR
Open Outward.
Right Hand "
", Hinges Right.
RH
Open Inward.
Right Hand Reverse "
", Hinges Right.
RHR
Open Outward.
The hand of a door is determined from the secure side of the
door. The term "secure" means the side from which you initially
unlock and enter.
Determining Handing
6
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL 7
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
3
Changing Handing
(if necessary)
4-24 x 1/4" PPHMS
4" Left Hand to 4" Right Hand Shown
x2
3
!
DO NOT TAMPER
WITH OR LOOSEN
E-CLIP AND ITS
ASSEMBLY
!
DO NOT LOOSEN
THESE 6 SCREWS
OR REMOVE
COVER Changing Handing
(if necessary)
continued
3
8
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL 9
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Lockset Handing Configurations
4" Left Hand
For 5.5"
For 4"
4" Right Hand
For 5.5"
For 4"
After handing is changed, check that lever and thumbturn rotate freely.
Test Lever and Thumbturn 10
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
4
Installing Fire Cups
Inside of Door
Both Fire Cups and a
marked
UL
Latchbolt must be used to
qualify for
listing.
UL
! 11
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
5
Adjusting Deadbolt Latch
(If adjustable deadbolt latch provided)
O
optional
default
UP
2-3/8" position
UP
2-3/4" position
Press
Pull 12
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
6
Installing Deadbolt Latch & Latchbolt
x4
7-16 / 8-32 x 1" UNCWS
Curved edge of latchbolt
faces direction door closes.
!
Choose latchbolt
based on backset.
(2-3/8" or 2-3/4")
Inside of Door
Bolt must be in
retracted (unlocked)
position before
installing.
!
Ensure arrow
stamped on deadbolt
is
.
UP
!
UP 13
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
M6x55 PPHMS
U
P
Inside of Door
x2
7
Installing Exterior Deadbolt
UP
Bolt must be in
retracted (unlocked)
position.
! 14
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
8
Installing Lock Chassis
10-32 x 1-1/2" PPHMS
Inside of Door
x2
U
P 15
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
9
Securing Back Plate to Door
x2
#6-32 x 1/2" POHMS
!
!
#6-32 x 1/2" POHMS
screws must be used
to qualify for
listing.
UL
Drill two
pilot holes
Ø1/8"
x 1/2" deep
Inside of Door
U
P 16
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Testing Deadbolt & Latchbolt Operation
Outside of Door 17
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
10
Remove Battery Cover
Loosen screw
to remove cover. 18
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
11
Attaching the Cable Assembly
Cable must be routed
as shown to avoid
interference with
movement
of lock.
!
U
P
Inside of Door
Align wire connectors so
that tabs slide into slots. Tug
gently on cables to test that
connectors are secure.
!
Ta b
Slot
Ta b
Slot 19
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
12
Installing Interior Lock
Turn
thumbturn
to adjust slot
orientation.
!
!
U
P
Orientation must match.
Do not fasten lock to back plate
until properly fitted.
Inside of Door 20
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
12
Installing Interior Lock continued
10-32 x 5/8" POHMS
x1
6-32 x 1" PPHMS
x2
Inside of Door
DO NOT
LOOSEN
THIS SCREW
! 21
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Pull lever
to ensure
it is secure.
13
""
SNAP
Installing Interior Lever
Inside of Door
Inside of Door 22
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Testing Final Latchbolt Operation
Outside of Door
Inside of Door Testing Final Deadbolt Operation
If testing fails, go back to beginning of
Step 12 and check installation.
!
23
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL 14
Installing Optional Network Module
DO NOT install
network module
with batteries in
unit. Damage
may occur.
!
Bolt must be
in retracted
(unlocked)
position
before
installing
batteries.
!
Tighten screw
to replace cover.
"Welcome to ..."
15
Installing Batteries & Cover
(Optional - Not
available on YRC620)
24
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL 25
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Handing the Lock
AFTER installing batteries and cover
or
a factory reset,
AFTER
create Master
code.
PIN
See 1 of Programming Instructions.
After entering the Master
code:
PIN
Press Advanced Lock Settings
Press to Select
Press Handing the Lock
Press to Select
Press to complete
Lock will cycle motor
to complete handing.
Congratulations, you've installed the
Yale Assure Lock Electronic Interconnected Touchscreen!
®®
Continue with the Programming Instructions
to customize your product. 26
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Hardware Troubleshooting
Cycle lock in both the locked and unlocked positions. If problems are found:
Bolt will not deadlock
a. Check for sufficient clearance of the bolt within the strike-side jamb.
Correct this by increasing the depth of the pocket for the bolt.
b. Check for misalignment of bolt and/or strike which may be preventing bolt
from properly entering the strike. With the door open, extend and retract the
bolt; if it is smooth, check the strike alignment.
Bolt does not extend or retract smoothly
a. Bolt and strike are misaligned, see above.
b. Check the backset of door relative to adjustments already made to bolt.
c. Verify proper door preparation and re-bore holes that are too small or
misaligned.
d. Verify touchscreen wire harness is routed properly (see Step 10).
e. Verify bolt is installed with correct side up (see Step 6).
Keypad numerics are scrolling
Remove interior escutcheon:
a. Check that wire terminals are securely connected.
b. Check that wire harness lies flat against mounting plate and is routed
through wire hook on mounting plate so cable is not pinched at any point.
Door is binding
a. Check that door and frame are properly aligned and door is free swinging.
b. Check hinges: They should not be loose or have excessive wear on knuckles.
Bolt will not extend and motor is grinding
a. Enter your Master
code.
PIN
b. With the bolt retracted, press menu Option 3 for Advanced Lock Settings.
c. Press Option 5 to rehand the lock.
d. Test the operation; locking the door via the keypad. 27
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Changing Lock: Replacing Cylinder
To remove cylinder:
A. Remove touchscreen from door.
B. Remove pan head screw.
C. Remove cylinder by letting it drop out of assembly.
C
B
Touchscreen shown
removed from door.
A
Reset Button
Access
Interior Lock
(4" Shown)
When resetting the lock, all user codes, including the
Master
code*, are deleted. All programming features
PIN
are reset to original default settings (see below).
1. Remove the battery cover and batteries.
2. Remove the interior lock to access the reset button hole.
(See image at right.)
3. Re-insert 3 batteries and insert a small screwdriver into
the hole; holding the reset button for 3 seconds.
4. While still holding the reset button, insert the 4th battery
and hold the reset button for an additional 3 seconds.
5. Release the reset button.
6. Re-install the interior lock onto the door.
Upon reset, Master
Code creation is the only option
PIN
available and must be performed prior to any other
programming of the lock.
For best results, the lock should be installed on the
door when resetting the lock to factory default. If the
process was done and the lock was not installed on
the door, review the Re-Handing instructions listed in
Hardware Troubleshooting.
Resetting Lock to Factory Default 28
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Programming Instructions
Lock Activation
Interior Lock
Privacy
Mode
Button
Speaker
"P" Key
(Return to Previous)
Low Battery
Indicator
Lockout
Mode
Touchscreen
OR
Master
Code must be created before any further programming.
PIN
Max User Codes = 250 with Z-Wave Plus or ZigBee network module
Max User Codes = 25 without network module or with iM1 network module
Max User Codes = 12 with Bluetooth 1
Creating Master
Code
PIN
Enter 4-8
digit Master
Code.
PIN
Creating a Master
Code must be performed upon installation or after
PIN
resetting the lock to factory default. Programming and use of lock is not
possible until this step has been successfully completed.
Press
Press
"Register Master
Code. Press the gear
key to continue."
"Enter a 4 to 8 digit
code followed by
PIN
the gear key."
"Entered."
29
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL 2
Creating User
Codes
PIN
Enter Master
code
PIN
Press
Press
Press
Press
Press
Master
code must be created first.
PIN
*Max user codes = 250 with Z-Wave or ZigBee network module
Max user codes = 25 without network module or with iM1 network module
Max user codes = 12 with Bluetooth
Enter 4-8 digit
code
PIN
Press
Press
(code flashes)
Press
Enter 4-8 digit
code
PIN
Press
Adding more *User Codes:
To end programming:
"Menu Mode,
enter number,
press the gear key
to continue."
30
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL 31
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
3
Unlocking Door with
Code
PIN
Enter
Code
PIN
Press
Factory Settings
*The Master
code must be registered prior to any other
PIN
programming of the lock.
Factory Setting
Registration
required*
Disabled
Disabled (Off)
Enabled
Enabled (Low)
5 Times
60 Seconds
Settings
Master
Code
PIN
Automatic Re-lock
Inside Indicator Light
One Touch Locking
Volume Setting
Wrong Code Entry Limit
Shutdown Time
Disabled
Privacy Button Setting
Disabled
Lockout Mode
English
Language Setting 32
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Definitions
All Code Lockout Mode:
This feature is enabled by the Master code. When enabled, it restricts all user (except
Master)
code access. When attempting to enter a code while the unit is in Lockout, the
locked padlock will
PIN
RED
appear on the screen.
Automatic Re-lock Time:
After a successful unlock, the unit will re-lock automatically after duration selected in the
Advanced Lock Settings
(Main Menu selection #3).
Handing the Lock:
Lock handing refers to which direction the bolt comes out of the door (right or left). If the lock
was programmed off the door, the lock may need adjusting. Review Handing the Lock instructions and/or Re-
Handing instructions listed in Hardware Troubleshooting.
Inside Indicator Light:
Located on the interior lock. Shows active status (Locked) of lock and can be enabled or
disabled in the
(Main Menu selection #3).
Advanced Lock Settings
Language Setting Mode:
Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the
lock's voice prompts.
Low Battery:
When battery power is low, the Low Battery Warning indicator flashes
. If battery power is
RED
completely lost, use the cylinder key override.
Master
Code:
It must be created prior
PIN
The Master
code is used for programming and for feature settings.
PIN
to programming the lock.
The Master code will also operate (unlock/lock) the lock.
Network Module Setting:
With the optional Network Module installed, this setting becomes available thru the Main
Menu (7) and allows the lock to connect with a network controller.
One Touch Locking:
When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-
lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is
in use
any valid
not
(disabled),
PIN code will re-lock the lock.
Previous:
While in Menu Mode, pressing this icon cancels the current operation and returns the user to the
previous step.
Privacy Mode:
Privacy mode is disabled by default. Enable Privacy Mode by pressing the privacy button for 4
seconds to put the lock in do-not-disturb mode (all pin codes are disabled).
Shutdown Time:
The unit will shutdown (flashing
) for sixty (60) seconds and not allow operation after the
RED
wrong code entry limit (5 attempts) has been met.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
User
Code:
PIN
The User code operates the lock. Maximum number of user codes with Z-Wave Plus or ZigBee
network module is 250; without network module or with iM1 network module, maximum is 25; with Bluetooth,
maximum is 12. Note: When deleting user pin code(s), screen will display user pin code being deleted.
Volume Setting Mode:
Low (2)
The volume setting for
code verification is set to
by default; otherwise it can be
PIN
set to
or
for quiet areas.
High (1)
Silent (3)
Wrong Code Entry Limit:
After five (5) unsuccessful attempts at entering a valid
code, the unit will shut down
PIN
and not allow operation for sixty (60) seconds. 33
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
1. Touch screen with back of hand or palm to activate.
2. Enter 4-8 digit master
code* followed by key.
PIN
Lock Response: " Menu mode, enter number, press key to continue."
3. Enter digit corresponding to the function to be performed followed by the key.
Follow the voice commands.
Model
226 Feature Programming Through
YRC
Menu Mode Using Master
code*
PIN
*The Master
code must be registered prior to any other programming of the lock.
PIN
M
U
**This function appears only with
network module installed.
Default settings
in
bold.
Master
Code Setting
PIN
User
Code Registration
PIN
Continue
Complete
Register
Delete
Continue
Complete
M
2
3
1
Join the Network
Enable
Disable
English
Spanish
French
Silent
Low
High
Complete
Exit the Network
Volume Setting
Language Setting Mode
Lockout Mode
**Network Module Setting
Privacy Setting Mode
Enable
Disable
Handing the Lock
Preforms automatic
handing of the lock
Advanced Lock Settings
Automatic Re-lock
Disable
30 sec
Inside Indicator Light
One Touch Locking
Enable
Disable
Enable
Disable
Continue
60 sec
3 min
2 min
Continue
Complete 34
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Model
620 Feature Programming Through
YRC
Menu Mode Using Master
code*
PIN
1. Touch screen with back of hand or palm to activate.
2. Enter 4-8 digit master
code* followed by key.
PIN
Lock Response: " Menu mode, enter number, press key to continue."
3. Enter digit corresponding to the function to be performed followed by the key.
Follow the voice commands.
*The Master
code must be registered prior to any other programming of the lock.
PIN
M
U
Default settings
in
bold.
Master
Code Setting
PIN
User
Code Registration
PIN
Continue
Complete
Register
Delete
Continue
Complete
M
2
3
1
Enable
Disable
English
Spanish
French
Silent
Low
High
Complete
Volume Setting
Language Setting Mode
Lockout Mode
Set Up
Card
SEOS
Privacy Setting Mode
Enable
Disable
Handing the Lock
Preforms automatic
handing of the lock
Advanced Lock Settings
*Automatic Re-lock
Inside Indicator Light
One Touch Locking
Enable
Disable
Enable
Disable
Continue
Continue
Complete
Enable
Disable
*Escape Return Mode
Enable
Disable
Enter Time 1-180 Sec
Continue
Complete
*If Escape Return Mode is enabled,
Automatic Re-lock cannot be enabled. 35
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
Programming Troubleshooting



























Symptom
Suggested Action 36
P/N
-
-
-
Rev G
YRL EMICL TSINSTL FUL
FCC:
Class B Equipment
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the
Rules. These limits are designed to provide reasonable protection against
FCC
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful Interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Ÿ
Reorient or relocate the receiving antenna.
Ÿ
Increase the separation between the equipment and receiver.
Ÿ
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Ÿ
Consult the dealer or an experienced radio/
technician for help.
TV
Industry Canada:
This Class A digital apparatus meets all requirements of the Canadian Interference Causing
Equipment Regulations.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des
règlements d'équipement.
Warning:
Yale Security Inc.
Changes or modifications to this device, not expressly approved by
could void the
user's authority to operate the equipment.
Yale® ,Yale Real Living® and Assure Lock® are registered trademarks of Assa Abloy Residential Group.
Other products' brand names may be trademarks or registered trademarks of their respective owners and are
mentioned for reference purposes only. © Copyright 2018. All rights reserved. Reproduction in whole or in part
without the express written permission of Assa Abloy Residential Group is prohibited.
Product Support Tel 1-855-213-5841 • www.yalehome.com Yale Z
Plus Module
®®
-Wave
Installation and Programming Instructions
Installing the Z
Plus Module
-Wave
®
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave
Plus messages to communicate to other security enabled Z-Wave Plus products. This device
must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize
all implemented functions. This product can be operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers. All non-battery operated nodes within
the network will act as repeaters regardless of vendor to increase reliability of the network.
To Enroll/Add the Module (Inclusion Mode):
• Enter the 4-8 digit Master
code followed by the key.
PIN
• Press the key followed by the key.
• Press the key followed by the key.
To Unenroll/Remove the Module (Exclusion Mode):
• Enter the 4-8 digit Master
code followed by the key.
PIN
• Press the key followed by the key.
• Press the key followed by the key.
Factory Reset - If No Controller:
• See the Lock Installation Manual
• Please use this procedure only when the network primary controller is missing or
otherwise inoperable.
For System Integrators: Specific Z-Wave Plus association and parameter information for your
lock is available at YaleHome.com/ZwavePlus.
Enrolling/Unenrolling the Network Module:
IMPORTANT:
the batteries
be removed prior
must
to removing and/or inserting the network module:
• Remove battery cover and batteries.
• Remove and/or insert Network Module.
• Reinstall batteries and battery cover.
P/N
202-
-
-
Rev D
AYR
ZW INSTAL FUL
® !
Warning:
Changes or modifications to this device, not expressly approved by Yale Security
Inc. could void the user's authority to operate the equipment.
FCC:
Contain
: U4A-
0
FCC ID
YRHCPZW FM
Model:
2-
YRMZW US
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of
the
Rules. These limits are designed to provide
FCC
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
Interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
Ÿ
Reorient or relocate the receiving antenna.
Ÿ
Increase the separation between the equipment and
receiver.
Ÿ
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Ÿ
Consult the dealer or an experienced radio/TV
technician for help.
THIS DEVICE COMPLIES WITH PART OF THE FCC RULES
15
.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE AND
THIS DEVICE MUST ACCEPT ANY
,
(2)
INTERFERENCE RECEIVED INCLUDING INTERFERENCE
,
THAT MAY CAUSE UNDESIRED OPERATION.
Industry Canada:
Contain
: 6982A-
0
IC
YRHCPZW FM
Model:
2-
YRMZW US
Section 7.1.2 of
-
RSS GEN
Under Industry Canada
regulations, this radio transmitter may only operate using
an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
En vertu des règlements d'Industrie Canada, cet émetteur
radio ne peut fonctionner avec une antenne d'un type et un
maximum (ou moins) approuvés pour gagner de l'émetteur
par Industrie Canada. Pour réduire le risque d'interférence
aux autres utilisateurs, le type d'antenne et son gain
doivent être choisies de façon que la puissance isotrope
rayonnée équivalente (
) ne dépasse pas ce qui est
PIRE
nécessaire pour une communication réussie.
Section 7.1.3 of
-
RSS GEN
This Device complies with
Industry Canada License-exempt
standard(s).
RSS
Operation is subject to the following two conditions: 1) this
device may not cause interference, and 2) this device must
accept any interference, including interference that may
cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada RSS
standard exemptes de licence(s). Son fonctionnement est
soumis aux deux conditions suivantes: 1) ce dispositif ne
peut causer des interférences, et 2) cet appareil doit
accepter toute interférence, y compris les interférences qui
peuvent causer un mauvais fonctionnement du dispositif.
This radio transmitter 6982A-
0
has been
YRHCPZW FM
approved by Industry Canada to operate with the antenna
types listed below with the maximum permissible gain
indicated. Antenna types not included in this list, having a
gain greater than the maximum gain indicated for that
type, are strictly prohibited for use with this device.
Le présent émetteur radio 6982A-
0
a été
YRHCPZW FM
approuvé par Industrie Canada pour fonctionner avec les
types d'antenne énumérés ci-dessous et ayant un gain
admissible maximal. Les types d'antenne non inclus dans
cette liste, et dont le gain est supérieur au gain maximal
indiqué, sont strictement interdits pour l'exploitation de
l'émetteur.
CAN ICES
NMB
-3B/
-3B
Product Support Tel 1-855-213-5841 • www.yalehome.com
Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company.
Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for
reference purposes only. Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
YALE,
with its unique global reach and range of products, is the world's favorite lock
– the preferred solution for securing your home, family and personal belongings.
ASSA ABLOY
is the global leader in door opening solutions,
dedicated to satisfying end-user needs for security, safety and convenience. Yale ZigBee Module
®®
Installation and Programming Instructions
Installing the ZigBee Module
®
This device is a security enabled ZigBee product that is able to use encrypted ZigBee
messages to communicate to other security enabled ZigBee products. This device must be
used in conjunction with a Security Enabled ZigBee Controller in order to fully utilize all
implemented functions. This product can be operated in any ZigBee network with other
ZigBee certified devices from other manufacturers. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.
To Enroll the Module (Inclusion Mode):
• Enter the 4-8 digit Master
code followed by the key.
PIN
• Press the key followed by the key.
• Press the key followed by the key.
To Unenroll the Module (Exclusion Mode):
• Enter the 4-8 digit Master
code followed by the key.
PIN
• Press the key followed by the key.
• Press the key followed by the key.
Enrolling/Unenrolling the Network Module:
IMPORTANT:
the batteries
be removed prior
must
to removing and/or inserting the network module:
• Remove battery cover.
• Remove batteries.
• Remove and/or insert network module.
• Reinstall batteries.
• Replace cover.
P/N
202-
-
-
Rev C
AYR
ZB INSTAL FUL
® FCC:
FCC ID
YRHCPZB FM
: U4A-
0
Model:
2
YRMZB
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of
the
Rules. These limits are designed to provide
FCC
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
Interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Ÿ
Reorient or relocate the receiving antenna.
Ÿ
Increase the separation between the equipment and
receiver.
Ÿ
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Ÿ
CTV
onsult the dealer or an experienced radio/
technician for help.
This equipment complies with
radiation exposure
FCC
limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum
distance 20cm between the radiator and your body. This
transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
This device complies with Part 15 of the
rules.
FCC
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation. Any
changes or modifications not expressly approved by
manufacturer could void the user’s authority to operate the
equipment.
IMPORTANT!
Any changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
Industry Canada:
IC
YRHCPZB FM
: 6982A-
0
Model:
2
YRMZB
This Device complies with Industry Canada License-exempt
RSS standard(s). Operation is subject to the following two
conditions: 1) this device may not cause interference, and
2) this device must accept any interference, including
interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux
d'Industrie
CNR
Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, meme si le brouillage est susceptible
d'en compromettre le fonctionnement.
Important Note:
Radiation Exposure Statement:
This equipment complies with
radiation exposure limits
IC
set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance
20cm between the radiator and your body.
Note Importante: (Pour l’utilisation de dispositifs
mobiles)
Declaration d’exposition aus radiations:
Cet équipement est conforme aux limites d ́exposition aux
rayonnements
établies pour un environnement non
IC
contrôlé. Cet équipment doit être installé et utilisé avec un
mimimum de 20 cm de distance entre la source de
rayonnement et votre corps.
IMPORTANT!
Any changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
IMPORTANT!
Tous les changements ou modifications pas
expressément approuvés par la partie responsable de la
conformité ont pu vider l’autorité de l’utilisateur pour
actioner cet équipment.
CAN ICES
NMB
-3B/
-3B
Product Support Tel 1-855-213-5841 • www.yalehome.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
YALE,
with its unique global reach and range of products, is the world's favorite lock
– the preferred solution for securing your home, family and personal belongings.
ASSA ABLOY
is the global leader in door opening solutions,
dedicated to satisfying end-user needs for security, safety and convenience.
Yale® and Yale Real Living® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company.
Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for referenc
e purposes only.
Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Yale iM1 Network Module
®
Installation and Programming Instructions
®
Installing the Yale iM1 Network Module
IMPORTANT:
the batteries
be removed prior
must
to removing and/or inserting the network module:
• Remove battery cover and batteries.
• Remove and/or insert Network Module.
• Reinstall batteries and battery cover.
Enrolling the iM1 Network Module:
The Yale iM1 Network Module must be used with a Yale Assure Lock or Yale nexTouch
Lock and cannot be used in conjunction with any other Yale Network Module.
To Enroll the Module:
•Enter the 4-8 digit Master
code followed by the key.
PIN
•Press the key followed by the key.
•Press the key followed by the key.
P/N
202-
-
-
Rev C
AYR
iM1 INSTAL FUL Yale®, Yale Real Living® and Assure Lock® are registered trademarks of Yale Security Inc., an ASSA ABLOY Group Company. nexTouch™ i
s a trademark of Yale Security Inc.,
an ASSA ABLOY Group Company. Other products’ brand names may be trademarks or registered trademarks of their respective owners an
d are mentioned for reference
purposes only. Copyright © 2017, Yale Security Inc., an ASSA ABLOY Group Company. All rights reserved. Reproduction in whole or in
part without the express written
permission of Yale Security Inc. is prohibited. Apple®, iPhone®, iPad®, iPod touch® and Siri® are trademarks of Apple Inc., regist
ered in the U.S. and other countries. HomeKit
is a trademark of Apple Inc. Use of the Works with Apple HomeKit logo means that an electronic accessory has been designed to con
nect specifically to iPod touch, iPhone or
iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for th
e operation of this device or its compliance with
safety and regulatory standards. Use of the HomeKit logo means that an electronic accessory has been designed to connect specifi
cally to iPod, iPhone, or iPad, respectively,
and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this
device or its compliance with safety and
regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
1. After following the steps listed on other side of page for enrolling the module, download the
Yale Secure app from the App Store .
®
2. Ensure Bluetooth is enabled on your iPhone , iPad or iPod touch , and that you're within a
®®®®
foot of your Yale lock.
3. Open the Yale Secure app and agree to allow the app to access your Home Data.
4. If you do not have a home already created, create a new home when prompted. Tap + to add
a new Yale Lock.
5. The app will search for your Yale Lock. Be sure that you are within close proximity (less than
two feet or so). When "Yale Lock" appears, tap to add.
*If the lock does not appear, enter your Master Pin Code on the lock keypad, tap the gear,
tap 7, tap gear, tap 1 and then tap gear.
6. Scan your Accessory Setup Code; shown below, or manually enter within the app.
Connecting the Yale Secure App with the Yale iM1 Network Module
Accessory Setup Code
Yale Secure App Connection
®
with Yale iM1 Network Module
®
®
Product Support Tel 1-855-213-5841 • www.yalehome.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
YALE,
with its unique global reach and range of products, is the world's favorite lock
– the preferred solution for securing your home, family and personal belongings.
ASSA ABLOY
is the global leader in door opening solutions,
dedicated to satisfying end-user needs for security, safety and convenience.


Uploaded