FEATURES & BENEFITS
• Detects attacks on
Bank vault doors,
ATMs, night deposit
safes, strong room
vaults, modular vaults,
vending machines,
freestanding safes,
hatches, gates, chests
and other objects with
a solid structure
• Detects attacks from
- Heavy strokes or
gross attacks from
sledgehammers or
explosives
- Repeated knocks
from hammers
and chisels
- Drilling, mechanical
cutting, acetylene
torches, thermal
cutting, water-cooled
diamond drills, water
jet cutting tools,
hydraulic jacks
(SC100 only)

• Compact size
Smallest available on
market so fi ts easier
when space is limited
• Universal (ATM and
vault)
The SC100 can also be
used for ATMs and
night deposit safes by
the simple change of a
DIP switch. No
separate sensors are
required.
• Drilling shield
(standard)
Protects electronics
inside against
sabotage
• Extended temperature
Allows operation in
extreme temperature
conditions (40° F to
158° F)
• Remote sensitivity
reduction input Option
to reduce sensor
sensitivity remotely
during maintenance on
ATMs, thereby
reducing false alarms
• Multi-compatible
mounting plate fi ts on
pre-fab holes
Fits on most pre-drilled
mounting holes from
other seismic sensors,
preventing time
consuming drilling/
threading. The same
mounting plate can be
used for mounting on
concrete and welding
on steel.
• Integrated End-ofLine
(EOL) resistors
EOL resistors for alarm
as well as tamper loop
are already
incorporated, saving
installation time and
reducing service calls
• Integrated temperature
alarm
The SC100 and SC105
will alarm if
the temperature
exceeds 185° F.
Additionally the SC100
version alarms when
temperature rises
faster than 6° F per
minute.
• Diagnostic LED
Built-in tool easily
selects correct
sensitivity; no time
consuming external
tools required

Selectable sensitivity
Four different
sensitivity settings
adapt to required range
and environmental
conditions
• Remote testing and
test transmitters Input
to remotely start
functional test with
help of SC113 (Internal
Test Transmitter) or
SC115 (External Test
Transmitter). If no test
transmitter is available,
it is possible to test
internal electronics
with this test.
• Available accessories
Mounting plate,
keyhole protection kit,
day/night kit, Internal
Test Transmitter,
armed cable and
External Test
Transmitter. This range
of accessories allows
the SC100 and SC105
Seismic Sensors to be
mounted in a wide
range of applications.
• Listed to UL639
• Listed to ULCS306
SC100 Series
Seismic VIBRATION sensors
Honeywell’s SC100 Series Seismic Vibration Sensors were designed
to protect high-value and high-risk assets in fi nancial, retail and other
applications.
The SC100 model detects vibrations arising from attempts to disturb solid
structures including fi xed ATMs, bank vaults, safes and doors. The SC105
was designed to safeguard freestanding objects like standalone ATMs, gun
cases, fi le cabinets, vending and ticket machines and more. Both models
can be installed in new or existing security systems and offer a higher level
of protection and false alarm immunity than traditional shock sensors,
which often lack the ability to discriminate between ambient vibration and
real attacks.
The SC100 Series contain several unique features that reduce installation
time and costs—including a Universal setting that lets dealers choose
between safes and vaults with the change of a DIP switch, integrated end-
of-line (EOL) resistors that improve connectivity to the control panel, a
built-in diagnostic tool and a compact size that enables placement inside
small areas. Honeywell reserves the right to alter the specification of products without notice.
SPECIFICATIONS
SC100
SC105
POWER
REQUIREMENTS
Supply Voltage
8 – 16VDC, nominal 12VDC
Current Consumption
Typical 3 mA @ 12VDC
SENSITIVITY
Adjustable Sensitivity
4 levels by DIP Switches
ATMs/Vault Selection
by DIP switch
N /A
Delayed Triggering
N /A
by DIP switch
Reduced Sensitivity Input
For maintenance & Service: Active low (<1.5 VDC)
Detection Radius
16.4’
9.8’
Alarm Algorithm
Highly sensitive to all known
attacks while rejecting known false alarm
sources by innovative fi lters
and fi rmware
Similar to the SC100, but adjusted for
noisy environments such as public areas
where ATMs may be located
ALARM OUTPUTS
Solid State Relay (Change Over)
30VDC/100 mA; Type C
30 VDC/100 mA; Type A
Open Collector
Active low during alarm
Alarm Hold Time
Approx. 2.5 secs
SABOTAGE
PROTECTION
Pry-off and Cover Switch
30 VDC/100 mA
Low Supply Voltage Alarm
< 7 VDC
Temperature Alarm
185° F, 23° F, 41° F
Internal Functional Alarm
Stainless steel drill shield
INPUTS
Remote Test
Active low 1.5 VDC, test duration < 0.5 sec
Reduced Sensitivity Input
Active low 1.5 VDC, test duration < 0.5 sec
Sensitivity reduction to 12.5 %
INSTALLATION TOOL
A noise and alarm indicator is incorporated to support sensitivity setting.
ENVIRONMENTAL
CONDITIONS
Maximum Humidity
95% RH (non-condensing)
Operating Temperature
40° F – 158° F
Storage Temperature
58° F – 158°
F
Environmental Class (VdS)
III
Housing Protection Category
IP43
HOUSING
Dimensions
3.15” H x 2.36” W x .83” D
Chassis and Cover
Die-cast metal
Color
RAL7035 (light gray)
Weight
.5 lbs.
APPLICATIONS
SC100
SC105
VAULT DOORS

ATMS

NIGHT DEPOSIT SAFES

STRONG ROOM VAULTS

MODULAR VAULTS

FREESTANDING SAFES

HATCHES

GATES


CHESTS


LOBBY ATMS

FILING CABINETS

CONTAINERS

VENDING MACHINES

TICKET MACHINES

DIP-switches
SC113 Test transmitter
connector
Diagnostic/
Alarm LED
Open collector
output setting
SC111 or SC112
connector for
accessories
Tamper switch
EOL resistor
jumpers
Terminal block
SC100 series accessories
SC110
SC111
SC112
SC114
SC115
SC116
SC117
SC118
SC113
SC100 Series Seismic sensors
Technical Specifi cations
ORDERING
SC100
Seismic Vibration Sensor (Safes/Vaults)
SC105
Seismic Vibration Sensor (ATMs)
SC110
Mounting Plate
SC111
Movable Mounting Kit
SC112
Keyhole Protection Kit
SC113
Internal Test Transmitter
SC114
5.9’ Armed Cable Kit (eight wires)
SC115
External Test Transmitter
SC116
Wall Recess Mounting Kit
SC117
Floor Recess Mouting Kit
SC118
Spacer for SC112 For more information:
www.honeywell.com/security
Honeywell Commercial Security
715 Peachtree Street NE
Atlanta, GA 30308
1.800.323.4576
www.honeywell.com
L/SC100D/D | 04/19
© 2019 Honeywell International Inc.


Uploaded