Qolsys Sensor Groups - Install Guide Excerpt Firmware 2.3.1



Related Products

Qolsys IQ Panel 2 Verizon - 7" Security Panel w/ Z-Wave-ready, Verizon Cell Communicator (QS9201-1200-840)(MFIMG)
Qolsys IQ Panel 2 Verizon LTE
7" Security Panel w/ Z-Wave-ready, Verizon Cell Communicator
Qolsys IQ Panel 2 Plus Verizon LTE, DSC Compatible - 433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus Verizon LTE, DSC Compatible
433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus - AT&T LTE with PowerG, S-Line & Legacy Interlogix
Qolsys IQ Panel 2 Plus AT&T LTE, Interlogix/GE Compatible
319.5 MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus AT&T LTE, DSC Compatible - 433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus AT&T LTE, DSC Compatible
433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 AT&T - Wireless Security System with AT&T LTE Communicator Installed (QS9202-1200-840)
Qolsys IQ Panel 2 AT&T LTE
Wireless Security System with AT&T Communicator Installed

Related Categories


Document Transcript

SENSOR GROUPS
GROUP
NAME
SUPERVISED
SCENARIO
10
Entry-Exit- Normal Delay
Y
Gives a period of time to exit the home or to disarm the panel when
returning before sounding the alarm
12
Entry-Exit- Long Delay
Y
Gives a period of time to exit the home or to disarm the panel when
returning before sounding the alarm. This can be a separate delay from
the “normal delay”
13
Instant Perimeter D/W
Y
Door or window that triggers an alarm
instantly
when system is armed
14
Instant Interior Door
Y
An interior sensor that triggers an alarm
instantly
while armed to both
stay and away. Does not trip if an entry/exit sensor is tripped first
16
Away Instant- Follower
Delay
Y
Interior door that
triggers alarm instantly
when system is armed to away
mode only
DOOR/WINDOW
IQ Panel 2+ supports PowerG along with ONE “legacy” frequency (319.5 MHz, 345 MHz, or 433 MHz) depending on which
RF daughter card is pre-installed. Sensor Group numbers and behaviors remain the same across all frequencies. When
pairing a 345 MHz sensor with the Panel, an additional option for “Loop” number will be shown.
SENSOR GROUPS SENSOR GROUPS
GROUP
NAME
SUPERVISED
SCENARIO
25
Local Safety Sensor
Y
This sensor does
not
report or trigger an alarm. This is a
chime only
sensor
when “Activity Monitoring” is active, regardless of panel status. Used for
medicine cabinets, chemical storage etc
8
Reporting Safety Sensor
Y
This sensor reports to the central station and
triggers
an alarm

when
“Activity Monitoring” is active, regardless of panel status
9
Delayed Reporting Safety
Sensor
Y
This sensor reports to the central station and triggers an alarm when
"Activity Monitoring" is active, regardless of panel status. This sensor has
an entry delay
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

52
158
DOOR/WINDOW
*345 MHz door/window sensors will have the option to change the “Loop” number to 1 or 2. This will allow the sensor to
be programmed twice as 2 different zones.
* Power G Door/Window contact 9945 adds an additional drop down menu to determine the contact type, Reed Switch or
Wired. SENSOR GROUPS
MOTION/IMAGE SENSOR
GROUP
NAME
SUPERVISED
SCENARIO
17
Away- Instant Motion
Y
Active only when armed to “Away”, and trips instantly when motion is
detected. Does
not
trip if an entry/exit sensor is tripped first
15
Stay- Instant Motion
Y
Active in both “Stay” & “Away” modes, and trips instantly when motion is
detected. Does
not
trip if an entry/exit sensor is tripped first
35
Stay- Delay Motion
Y
Active in both “Stay” & “Away” modes. Triggers an entry delay when
motion is detected. Does
not
trip if an entry/exit sensor is tripped first
20
Away- Delay Motion
Y
Active when armed to “Away”. Triggers an entry delay when motion is
detected. Does
not
trip if an entry/exit sensor is tripped first
25
Safety Motion
Y
This sensor does
not
report or trigger an alarm. This is a chime only sensor
when “Activity Monitoring” is active, regardless of panel status. Used for
medicine cabinets, storage, activity tracking, etc
*345 MHz motion sensors will have the option to change the “Loop” number to 1, 2 or 3. This will allow the sensor to be
programmed twice as 2 different zones where supported by the device.
*Power G Motion Detectors with Prefix 120, 122, 130, 140 and 142 offer additional functions such as Presence Detection
and Sensitivity Level. Motions with prefix 123, 127, 128 and 129 offer Presence only as an additional function. SENSOR GROUPS
GLASS BREAK
GROUP
NAME
SUPERVISED
SCENARIO
13
Glass Break
Y
Active in both “Stay” and “Away” mode
17
Glass Break -Away
Only
Y
Active in “Away” mode only
KEY FOB
GROUP
NAME
SUPERVISED
SCENARIO
1
Mobile Intrusion
N
Worn or carried
, the button(s) is/are programmed to trigger a
police panic
6
Mobile Auxiliary
N
Worn
as a wrist watch or pendant, the button(s) is/are programmed to trigger an
Auxiliary panic
.
NOTE:
Medical functionality has not been evaluated by UL/cUL
4
Fixed Auxiliary
Y
Installed in a
fixed location
such as night stand, the button(s) is/are programmed
to trigger an Auxiliary panic.
NOTE:
Medical functionality has not been evaluated by UL/cUL
*345 MHz Keyfobs will follow the IQ Panel’s Keyfob programming and functionality
*345 MHz glass break sensors can be programmed as “Loop” 1 only SENSOR GROUPS
KEYPAD
GROUP
NAME
SUPERVISED
SCENARIO
0
Fixed Intrusion
Y
Installed in a
fixed location
such as under a desk, the button(s) is/are
programmed to trigger a
police panic.
NOTE:
Hold-up functionality has not been evaluated
by UL/cUL
1
Mobile Intrusion
N
Keypad can be mobile
and is programmed to trigger a
police panic
2
Fixed Silent
Y
Installed in a
fixed location
such as under a desk, the button(s) is/are
programmed to trigger a
silent police panic
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

55
158 SENSOR GROUPS
AUXILIARY PENDANT
GROUP
NAME
SUPERVISED
SCENARIO
6
Mobile Auxiliary
N
Worn as a wrist watch or pendant, the button(s) is/are programmed to trigger an
A
uxiliary
panic
1
Mobile Intrusion
N
Worn or carried, the button(s) is/are programmed to trigger a
police panic
0
Fixed Intrusion
Y
Installed in a
fixed location
such us under a desk, the button(s) is/are
programmed to trigger a
police panic
2
Fixed Silent
Y
Installed in a
fixed location
such us under a desk, the button(s) is/are
programmed to trigger a
silent police panic
4
Fixed Auxiliary
Y
Installed in a
fixed location
such as night stand, the button(s) is/are programmed
to trigger an auxiliary panic
25
Safety Auxiliary
Pendant
N
Used for local alerts like a nurse call button. Will not report an alarm to the
Central Station
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

56
158
*345 MHz auxiliary pendants can be programmed as “Loop” 1 only SENSOR GROUPS
SMOKE DETECTOR/HEAT
GROUP
NAME
SUPERVISED
SCENARIO
26
Smoke-Heat
Y
Triggers an alarm when sensor detects smoke/rapid rise in heat
GROUP
NAME
SUPERVISED
SCENARIO
34
CO
Y
Triggers an alarm when sensor detects Carbon Monoxide
CO DETECTOR
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

57
158
SMOKE-M
GROUP
NAME
SUPERVISED
SCENARIO
26
Smoke-Heat
Y
Triggers an alarm when sensor detects smoke or a rapid rise of heat.
Use
ONLY
with Qolsys multi-sensor smoke (QS5110-840)
*345 MHz carbon monoxide sensors can be programmed as “Loop” 1 only
*345 MHz smoke sensors will have the option to change the “Loop” number
to 1, 2 or 3. This will allow the sensor to be programmed twice as 2 different
zones where supported by the device HARDWIRE TRANSLATOR
GROUP
NAME
SUPERVISED
SCENARIO
13
Takeover
Y
Triggers an alarm when sensor is tampered in “Stay” or “Away”
mode
GROUP
NAME
SUPERVISED
SCENARIO
13
Translator
Y
Triggers an alarm when sensor is tampered in “Stay” or “Away”
mode
WIRELESS TRANSLATOR
SENSOR GROUPS
TEMPERATURE
GROUP
NAME
SUPERVISED
SCENARIO
51
Temp Non Reporting
Y
Only for use with the PowerG Temp Sensor (PG9905). This sensor
group does
not
report to the Central Station. Allows for actual
temperature monitoring (thermometer) with customizable high/
low threshold settings SENSOR GROUPS
GROUP
NAME
SUPERVISED
SCENARIO
38
Water Sensor
Y
Triggers an alarm when sensor detects presence of water.
NOTE:
flood sensor functionality has not been evaluated by UL/cUL
SHOCK SENSOR
GROUP
NAME
SUPERVISED
SCENARIO
13
Shock-Glass-Break
Y
Arms and trips shock sensors immediately when armed to both
“Stay” and “Away”
17
Glass-Break-Away Only
Y
Arms and trips shock sensors immediately when armed only to
“Away”
Please note:
When selecting “Water” you will see two additional options under “Sensor Sub-Type”. For IQ TempH20
(QS5500-PO1) & the IQ Flood (QS5516-840/QS5536-840) select “Multi-Function-1”, for all others, select“Flood-2”
Please note:
When selecting “Shock” you will see two additional options under “Sensor Sub-Type”
For IQ Shock select “IQ Shock”, for all others select “Other Shock”
*Power G Shock Sensor with prefix 170 offers additional sensitivity level functions
WATER
*345 MHz water sensors will have the option to change the “Loop” number to 1, 2 or 3. This will
allow the sensor to be programmed twice as 2 different zones where supported by the device
*345 MHz shock sensors will have the option to change the “Loop” number to 1 or 3. This will
allow the sensor to be programmed twice as 2 different zones where supported by the device SENSOR GROUPS
TILT
GROUP
NAME
SUPERVISED
SCENARIO
10
Entry-Exit- Normal
Delay
Y
Triggers alarm after “normal delay” expires. Arms with both “Stay”
and “Away”
12
Entry-Exit- Long Delay
Y
Triggers alarm after “long delay” expires. Arms with both “Stay” and
“Away
25
Garage Tilt- Safety Tilt
Y
This sensor group does
not
report or trigger an alarm. This is a chime
only sensor when “Activity Monitoring” is active, regardless of panel
status. Great for detached garage/shops.
NOTE:
Functionality in
conjunction with garage door openers has not been evaluated by UL/cUL
FREEZE
GROUP
NAME
SUPERVISED
SCENARIO
52
Freeze
Y
Triggers an alarm when sensor detects low temperatures.
NOTE:
temperature sensor functionality has not been evaluated by UL/cUL
*345 MHz temp sensors can be programmed as “Loop” 1 only
*345 MHz tilt sensors can be programmed as “Loop” 3 only
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

60
158 SENSOR GROUPS
DOOR BELL
GROUP
NAME
SUPERVISED
SCENARIO
25
Local Safety Sensor
Y
This sensor does
not
report or trigger an alarm. This is a chime only
sensor when “Activity Monitoring” is active, regardless of panel
status. Great to automate lights, cameras and notifications etc
SIREN
GROUP
NAME
SUPERVISED
SCENARIO
33
Siren
Y
Used for supervising Z-Wave sirens for wireless connectivity.
Reports to the central station.
25
Local Safety Sensor
Y
Used for supervising Z-Wave sirens for wireless connectivity. Local
supervision only. Does
NOT
report to the central station.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

61
158 SENSOR GROUPS
DOOR/WINDOW-M
(For use only with Multi-function Door/Window Sensors)
GROUP
NAME
SUPERVISED
SCENARIO
10
Entry-Exit- Normal Delay
Y
Gives a period of time to exit the home or to disarm the panel when
returning before sounding the alarm
12
Entry-Exit- Long Delay
Y
Gives a period of time to exit the home or to disarm the panel when
returning before sounding the alarm. This can be a separate delay from
the “normal delay”
13
Instant Perimeter D/W
Y
Door or window that triggers alarm
instantly
when system is armed
14
Instant Interior Door
Y
An interior sensor that triggers an alarm
instantly
while armed to both
stay and away. Does not trip if an entry/exit sensor is tripped first
16
Away Instant- Follower
Delay
Y
Interior door that
triggers alarm instantly
when system is armed to away
mode only
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE

OF

62
158 SENSOR GROUPS
DOOR/WINDOW-M
(For use only with Multi-function Door/Window Sensors)
GROUP
NAME
SUPERVISED
SCENARIO
25
Local Safety Sensor
Y
This sensor does
not
report or trigger an alarm. This is a
chime only
sensor
when “Activity Monitoring” is active, regardless of panel status. Used for
medicine cabinets, chemical storage etc
8
Reporting Safety Sensor
Y
This sensor reports to the central station and
triggers
an alarm

when
“Activity Monitoring” is active, regardless of panel status
9
Delayed Reporting Safety
Sensor
Y
This sensor reports to the central station and triggers an alarm when
"Activity Monitoring" is active, regardless of panel status. This sensor has
an entry delay
OCCUPANCY SENSOR
GROUP
NAME
SUPERVISED
SCENARIO
25
Occupancy Sensor
Y
This sensor group is to be used for monitoring activity in the home. This
group does not report


Uploaded