Document Transcript


IS3
035V

Passive Infrared
Motion Sensor

Détecteur de mouvem
ent
à infraro
uge passif

Sensor de m
ovimiento
Pasio Infrarrojo

Sensor de
m
ovimento

infravermelho passivo


Quick
Installation Guide

Guide d’installation rapide

Guía
Rápida
de instalación

Guia
rápido
de instalação









- 2 -






1.

Close the sensor and apply power. Initialization is complete when
the LED stops flashing slowly (about 30 seconds).

2.

Walk t
hrough the detection area and observe the LED.

LED

Power Up

Walk Test

Normal

Fault

Red

Slow

Blink

ON

Alarm

ON

Alarm

Fast

Blink


Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal
operation
mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature (see Walk
Test Reset above).

Note
: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting.






- 3 -
SPECIFICATIONS

Operating Temperature
:
................................
....................................................................................................................
14° to 131°
F / -
10° to 55°C

Relative Humidity
: ................................
..................................................................................................
5 to 93
% (UL tested at 93%)
; non-
condensing

Dimensions:
................................
........................................................................................................................
3.86 x 2.24 x 1.69in / 98
x 57 x
43mm

Tamper
:
....................................................................................................................................................................
Cover and Wall Tamper Protection

Electrical Power:
..........................................................................................................................................
15mA (normal use); 17mA (maximum use)

Range:
................................
........................................................................................................
Cone shape detection area of 40 x 56ft (
12.2 x 17.1m)

Pet Immunity:
.....................................................................................................................................................................................
Up to 80lb / 36
kg)


TROUBLESHOOTING



TROUBLE*


NORMAL

Self
-
Test Failure
1

Alarm Relay

Closed

Open

Red LED

Off

Flashing

*TROUBLE CONDITIONS

1
Self
-Test Failure conditions:

• PIR self
-test failure:
The sensor is disabled.

• Temperature compensation failure: The temperature compensation is disabled.

Depending on the Trouble condition, take the following corrective actions:

• Verify the power
supply is sufficient (at least 9V at the sensor).

• Cycle power to the sensor.

• Walk test the sensor.



If the Trouble condition does not clear, replace the sensor.


APPROVAL
LISTINGS


FCC part 15, Class B verified


IC ICES
-003, Class B ve
rified


UL 639


ULC S306
-03


SIA-
PIR
-01 Passive Infrared detector standard features for false alarm immunity.

Product must be tested at least once each year / Le fonctionnement du produit doit être vérifié au moins une fois par année /
El producto debe s
er probado al menos una vez al año /
O produto deve ser testado pelo menos uma vez por ano
All wiring must be in accordance with: the National Electrical Code (ANSI/NFPA70); the Canadian Electrical Code, Part I (wher
e applicable);
UL681, Standard for Insta
llation and Classification of Burglar and Holdup Alarm Systems; ULC
-S302, Standard for Installation and
Classification of Burglar Alarm Systems for Financial and Commercial Premises, Safes and Vaults; ULC
-S310, Standard for Installation and
Classification
of Residential Burglar Alarm Systems; local codes and the authorities having jurisdiction.

The products are intended to be powered by a power
-limited output of a UL/CUL Listed Burglar Alarm control unit, or via a Listed UL603/ULC
-
S318 power
-limited power s
upply that provides 4 hours of standby power
.
The sensor must be mounted indoors, within the protected premises, and on a wooden stud, solid wood or with a robust wall anc
hor.

UL Notes
: All interconnecting devices must be UL listed. The
pet immunity feature has not been evaluated by UL.


FEDERAL COMMUNICATIONS COMMISSION STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or U
ser's Manual.
Unauthorized changes or modifications
could void the user's authority to operate the equipment.

CLASS B DIGITAL DEVICE STATEMENT

This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following stat
ement for your
information:

This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the m
anufacturer's
instructions, may cause interference to radio and television reception. It has been type tested and found to comply w
ith the limits for a Class B
computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable prot
ection against such
interference in a residential installation. However, there is no guarantee that in
terference will not occur in a particular installation. If this equipment does
cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct
the interference by one or more of the following measures:

• Reorient the receiving antenna until interference is reduced or eliminated.

• Move the radio or television receiver away from the receiver/control.

• Move the antenna leads away from any wire runs to the receiver/c
ontrol.

• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch cir
cuits.

• Consult the dealer or an experienced radio/TV technician for help.

INDUSTRY CANADA CLASS B STATEMENT

This Clas
s B digital apparatus complies with Canadian ICES
-003.

Cet appareil numérique de la classe B est conforme à la norme NMB
-003 du Canada.

FCC/IC NOTICE:
This device complies with Part 15 of the FCC Rules, and RSS
-210 of IC. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired
operation.


Cet appareil est conforme à la partie 15 des règles de la FCC & de RS
S-210 des Industries Canada. Son fonctionnement est soumis aux conditions
suivantes: (1) Cet appareil ne doit pas causer d' interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception i
ndésirable.




TO THE INSTALLER

Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous
satisfactory operation of any alarm system. The installer should assume the responsibility of
developing and offering a regular
maintenance program to the user, as well as acquainting the user with the proper operation and limitations of the alarm system and
its component parts. Recommendations must be included for a specific program of frequent te
sting (at least weekly) to insure the
system’s operation at all times.


REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING
LIMITATIONS OF THE ENTIRE ALARM SYSTEM
.

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center
Drive., Melville, NY 11747, Ph: 516-
577-
2000


The product should not be disposed of with other household waste. Check for the nearest authorized c
ollection centers or authorized recyclers. The
correct disposal of end-
of-life equipment will help prevent potential negative consequences for the environment and human health.

Any attempt to reverse-
engineer this device by decoding proprietary protocols, de-
compiling firmware, or any similar actions is strictly prohibited.



To protect the environment, a detailed installation guide is available on the Resideo website –
Please consider before printing the document!




SUPPORT & WARRANTY INFORMATION
For
the latest documentation, support, and warranty information please go to:

www.resideo.com

































This product manufactured by Resideo Technologies
, Inc
. and its affiliates






2 Corporate Center Drive, Suite 100

P.O. Box 9040, M
elvi lle, NY 11747


2021
Resideo Technologies, Inc.

www.resideo.com



ÊR800
-26063D(Š

R800-26063
D 5/20 Rev. D


Uploaded