Tech TIP

ATTENTION TOTAL CONNECT

2.0 INSTALLER


TO AVOID A SETUP/PROGRAMMING ERROR MESSAGE: WHEN IN
STALLING THIS
SYSTEM FOR USE WITH TOTAL CONNECT 2.0, SEE THE PROG
RAMMING NOTES BELOW

This document applies to
Vista-21IPLTE panels
.

If you found this document included in the control
panel packaging,
it applies to your system
!
NOTE
: If you see the error message shown above, click t
he
TROUBLESHOOTING TIPS
button for a support
document that will help you clear the error.

REQUIRED CONTROL PANEL PROGRAMMING FOR TOTAL CONNEC
T 2.0:

STEP 1. Use program field

29 to set the communicator for IP/Cell.
NOTE
: To avoid overwriting Total Connect settings that
may have been previously programmed when
creating a Total Connect account,
do not
use the control panel’s

29



Communication Device Menu Mode
(pass-through programming) to program the communica
tor. Use AlarmNet360
®
instead.

a. In panel programming, select

29
b. Enter ‘1’ to enable IP/Cell, then select the sta
r key (

) to continue
c. If you are installing this system with an IP con
nection, press ‘0’ to exit field

29 program mode, then select
the star key (

) to continue to Step 2.
DO NOT FULLY ENTER

∗∗

29 COMMUNICATOR PROGRAM MODE


If you are installing this system with LTE-21V only
(no
IP connection), press ‘1’ to enter program mode and

toggle the Internal Device option to Cell only, the
n exit
programming as follows without entering the Primary

City ID at the next prompt:

After toggling to Cell Only: select Function Key D,
then
Function Key A, then select the pound key (#) to ex
it at
the
Review? Y/N
prompt.


STEP 2. Set program field

∗∗

189 to enable the Total Connect remote services key
pad
a. In panel programming, select

189
b. Enter 1, 5, 0, 0

∗∗

189

Touch Screen Device








[default = 1, 1, 0, 0]


(
AUI)

Enable

AUI 1 AUI 2 AUI 3 AUI 4

By default, the Total Connect (virtual) keypad will
be set to address 2 in the communicator programmin
g. The
suggested input of 1,5,0,0 assumes this programming
has been left at default and also assumes you have
a
touchscreen keypad installed for partition 1 at add
ress 1. See panel programming documentation for oth
er
valid inputs.
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
(B)
A
D
S
ENTER
SHIFT
N / Y
/
BS/ESC
SPACE
B
E
T
C
F
X
#
ARMED
READY
6160-7720P-001-V0
SHIFT
FUNCTION
WHEN LIT
(C)
(D)
(A)


Uploaded