How Do I Turn On ULC Power Restoration on the IQ Panel 5?

To turn on ULC Commercial Power Restoration on the IQ Panel 5, swipe down and touch Settings, then Advanced Settings, and enter your Installer Code. Next, touch Installation, then Installer Settings, and enable ULC Commercial Power Restoration for a full 120 second hold on sensor activity.

About ULC Commercial Power Restoration

ULC Commercial Power Restoration is a false-alarm-reduction feature on the IQ Panel 5 (available in AT&T LTE and Verizon LTE). When power is restored after an outage, sensors can briefly report activity as they power back up, which can cause a nuisance alarm. With this setting enabled, the panel ignores all sensor activity for 120 seconds after power comes back, giving your security system a two-minute window to settle before it acts on any sensor signals.

The feature is disabled by default, so out of the box the panel responds to sensors immediately when power returns. As the name suggests, the 120-second hold is intended to meet ULC commercial installation requirements, which call for a longer settling window than a typical home. Turning it on changes only the brief period right after power is restored and does not affect how sensors behave during normal operation.

Before You Begin

ULC Commercial Power Restoration is in the Installer Settings, which require the Installer Code (1111 by default) or Dealer Code (2222 by default). The steps below use the Installer Code. This is the commercial, 120-second version of the power-restoration hold, which is a longer window than the shorter residential power-restoration setting.

Turn On ULC Commercial Power Restoration

  1. Swipe down and touch Settings. Swipe down from the top of the screen to open the Settings Tray, then touch SETTINGS.

    IQ Panel 5 Settings Tray opened by swiping down from the top of the screenSwipe down from the top of the screen to open the Settings Tray.IQ Panel 5 Settings Tray with the Settings button highlightedTouch Settings in the Settings Tray.
  2. Touch Advanced Settings and enter your Installer Code. Touch ADVANCED SETTINGS, then enter your Installer Code (1111 by default). The Dealer Code (2222) works here too. The panel advances automatically after a valid code.

    IQ Panel 5 Settings page with Advanced Settings highlightedTouch Advanced Settings.IQ Panel 5 code entry keypad for Advanced SettingsEnter your Installer Code (1111 by default).
  3. Touch Installation, then Installer Settings. Touch INSTALLATION, then open INSTALLER SETTINGS and find the ULC Commercial Power Restoration setting.

    Open Installer Settings and find ULC Commercial Power Restoration.
  4. Enable ULC Commercial Power Restoration. Toggle ULC Commercial Power Restoration on. From now on, the panel will ignore all sensor activity for 120 seconds after power is restored. Toggle it off here any time to return to the default behavior.

    Toggle ULC Commercial Power Restoration on.

Tips

This 120-second hold is the commercial counterpart to the shorter SIA power-restoration setting, so for a typical home you would usually use the residential version instead. See our guide on how to turn on SIA Power Restoration on the IQ Panel 5 for that 60-second option. The hold only applies right after power returns and does not reduce your protection, so enabling it is a safe way to cut down on false alarms following an outage.

Turning on ULC Commercial Power Restoration on the IQ Panel 5 helps prevent false alarms when power comes back in a commercial setting. For help with ULC Commercial Power Restoration or other false-alarm settings on your IQ Panel 5, contact the Alarm Grid support team. We are here Monday through Friday from 9:00 AM to 8:00 PM Eastern Time. Email us at support@alarmgrid.com, call us at 888-818-7728, or visit our website and chat with a live support agent.

Did you find this answer useful?

We offer alarm monitoring as low as $10 / month

Click Here to Learn More