What Do Z-Wave Counters Show on the IQ5 Hub?

Z-Wave Counters on the IQ5 Hub show how many commands were acknowledged and how many failed, for the whole network or for one device. A well designed network should have at least a 98 percent acknowledgment rate versus failed commands. Open them in System Tests, then Z-Wave Tests.

What Z-Wave Counters Show

The IQ5 Hub (available in AT&T LTE and Verizon LTE) has a Counters test in its Z-Wave tests. The manual calls it a numerical representation of the Z-Wave network. It counts the commands the panel sent to your Z-Wave devices, and it shows how many were acknowledged and how many failed, either for the whole network or for one device.

A well designed network should have at least a 98 percent acknowledgment rate versus failed commands. Counters give you the numbers to check that.

How to Open Z-Wave Counters

1. Swipe down from the top of the screen. This opens the Settings Tray with quick controls.

2. Touch Settings, then touch Advanced Settings. This prompts you to enter a code before continuing.

3. Enter the Installer Code. The default Installer Code is 1111. The Dealer Code, 2222, also works.

4. Touch System Tests, then touch Z-Wave Tests. This opens the Z-Wave test options.

5. Touch Counters. The counters screen opens with the network totals, and the Reset All and Details buttons.

IQ5 Hub z-wave counters screen showing acked and failed command counts with reset all and details buttons, and a per device passed and failed list

IQ5 Hub Z-Wave Counters screens

6. Touch Details to see each device. The list shows each device with its passed and failed commands.

What Each Counter Means

Acked commands no auto route counts commands that succeeded and were acknowledged, but did not use the normal automatic route. The command was re-routed on the network in order to succeed. Acked commands auto route counts commands that succeeded and were acknowledged using the normal automatic route.

The failed counters explain why a command did not work. Failed commands network failed means the network was busy, or jammed, so the command was not sent. Failed commands network not idle means an auto-routed command failed because the network was not yet stable. Failed commands network no route means an auto-routed command failed because there is no successful route to the device. The screen also lists Failed commands no ack, which counts commands that were not acknowledged.

Reading the Numbers

Start with the acked totals. A healthy network has many acked commands and very few failed ones, so the acked total should be at least 98 percent of all commands. A high count of acked commands with no auto route means commands are being re-routed to succeed, which can point to a weak link. Failures from a busy network suggest interference, and failures with no route point to a device the panel cannot reach. Use these numbers to protect the devices that matter to your Z-Wave setup.

Per Device Counters and Reset

The Details view shows each device with its passed and failed commands, and it has a Reset button that clears the counters for one device only. Reset All sets every counter back to 0, so you can test again from a clean start.

Using Counters to Find a Problem Device

Reset All counters first, so old numbers do not hide the current problem. Use the Z-Wave devices normally for a day, such as turning lights on and off, and then open Counters again. A device with failed commands is the one to look at. Move it closer to the panel or to a repeater, and check its counter again later to see whether the failures stop.

When to Check the Counters

Check the counters after you add several Z-Wave devices, after you move a device, and whenever a light, lock, or thermostat responds slowly. A quick look takes a minute, and it tells you whether the network or a single device needs attention before the panel loses touch with it.

Other Z-Wave Tests

The Z-Wave tests menu has more tools for the same job. Rediscover Network refreshes the network, and Neighbor Info shows which devices each device can reach. Z-Wave Diagnostics draws a map of the network, and Advanced Z-Wave Diagnostics adds the Network Health Test, the Repeater Test, and Last Working Route. Counters are the numbers, so use them with the map to see the whole security system.

For complete protection, consider adding professional monitoring and home automation devices to your system.

Z-Wave Counters on your IQ5 Hub show how many commands your Z-Wave devices acknowledged and how many failed on the IQ5 Hub. For help with Z-Wave tests or other System Tests or other configurations on your IQ5 Hub, contact the Alarm Grid support team. We are here Monday through Friday from 9:00 AM to 8:00 PM Eastern Time. Email us at support@alarmgrid.com, call us at 888-818-7728, or visit our website and chat with a live support agent.

Did you find this answer useful?

We offer alarm monitoring as low as $10 / month

Click Here to Learn More

Related Products

Taxons
IQ5 Hub PG Verizon LTE 10-1 Kit
PG+ System, 10 Door/Window and 1 Motion Sensors
List Price:
Our Price: $589.99
Taxons
IQ5 Hub PG AT&T LTE 10-1 Kit
PG+ System, 10 Door/Window and 1 Motion Sensors
List Price:
Our Price: $589.99

Related Categories


Answered