Honeywell VISTA-15PSIA Frequently Asked Questions

How Do I Program My Honeywell VISTA 15P?
When programming a VISTA 15P, you must first access system programming. Next, you will access the programming field that you want to adjust. From there, enter in the appropriate data. Finally, you will exit system programming to save your changes. Learn more about programming a VISTA 15P.
Added:

How Do I Program a Wired Zone on a Vista Panel?
Determine how you wish to connect your wired zone, then program each zone according to the way it is wired. Zone 1 must always be wired with a 2K end or line resistor. Zones 2 - 6 (15P) or 2 - 8 (20P, 21iP) can be programmed as Normally Open, Normally Closed, or EOL. Read on to learn more. Determine how you wish to connect your wired zone, then program each zone according to the way it is wired. Zone 1 must always be wired with a 2K end of line resistor. Zones 2 - 6 (15P) or 2 - 8 (20P, 21iP) can be programmed as Normally Open, Normally Closed, or EOL. Read on to learn more.
Added:

Should I Change My Installer Code?
Most users find that there is no need for them to change the Installer Code on their security panel. This is because leaving their Installer Code at the default does not present any sort of security risk. Also, changing the Installer Code can lead to confusion and extra hassle for the user later on.
Added:

Can I Get Notified by My VISTA When an Alarm is Set Off?
A user can choose to receive text and email alerts from Total Connect that will notify them whenever an alarm event occurs on their VISTA system. To do this, the VISTA system must first be set up with the Total Connect platform. An internet or cellular connection is needed to connect to the service.
Added:

Do I Need a 5881ENH on My VISTA Security System?
A VISTA security system will not require a 5881ENH, or any other type of wireless receiver, if only hard-wired sensors are going to be used with the panel.
Added:

How Do I Wire a 2-Wire Smoke Detector to My Wired Alarm System?
A 2-wire smoke detector connects directly to a hard-wired zone on a wired alarm system. Learn how to interface a 2-wire smoke with your wired alarm system.
Added:

How Do I Program the Alpha on My VISTA Panel?
Enter program mode, then press *82 to enter Alpha Descriptor Programming. Each zone can have up to a three word descriptor. Custom words can also be created.
Added:

What Panels Support the Maintenance Feature on the 5808W3?
Any panel that supports 5800 Series wireless can support maintenance supervision on the 5808W3. Read on to see how this feature is enabled on each panel.
Added:

What is the Difference Between a Master Code and a Normal User Code?
A master code has the ability to add, edit, and delete other user codes. It can never deleted, only edited. A user code can only arm, disarm, and bypass.
Added:

How Do I Enter Walk Test Mode on a Vista Panel?
You can enter walk test mode on the Vista-15P, 20P, 21iP panels by keying in Installer Code + [5] + [0]. The panel must be "Ready" to access test mode.
Added: