How Do I Add an IQ Smoke and Heat Detector to the IQ5 Hub?

To add an IQ Smoke and Heat detector to the IQ5 Hub, swipe down, touch Settings, Advanced Settings, enter the Installer Code (1111 by default), go to Installation, Devices, Security Sensors, touch Auto Learn, activate the QS5130-840, set Sensor Type to Smoke Detector, and touch Add New.

About the IQ Smoke and Heat Detector

The IQ5 Hub (available in AT&T LTE and Verizon LTE) is compatible with the Qolsys IQ Smoke QS5130-840, a Qolsys S-Line 319.5 MHz wireless smoke and heat detector. S-Line is built natively into the IQ5 Hub — no daughter card required. The QS5130-840 uses encrypted two-way S-Line communication for supervised wireless protection.

Once enrolled, the detector is always active and monitors 24 hours a day regardless of arming state. Smoke detectors use Sensor Group 26 and cannot be bypassed. With a monitoring plan, the central station receives the fire signal and can dispatch emergency services immediately. Install on every level of the home and near sleeping areas per local code requirements.

Steps to Add the IQ Smoke and Heat Detector

1. Swipe down from the top of the screen and touch Settings. The Settings page opens.

IQ5 Hub settings tray pulled down from the home screen

IQ5 Hub Settings Tray opened by swiping down from the top of the screen

2. Touch Advanced Settings and enter the Installer Code (1111 by default). The Advanced Settings menu opens.

 IQ5 Hub settings page with Advanced Settings highlighted

IQ5 Hub Advanced Settings highlighted on the Settings page

3. Touch Installation, then Devices, then Security Sensors. The Security Sensors menu opens.

IQ5 Hub advanced settings menu showing installation and devices categories

IQ5 Hub Advanced Settings installer menu categories

4. Touch Auto Learn Sensor. The panel enters listening mode for an S-Line signal.

IQ5 Hub auto learn sensor popup in listening mode

IQ5 Hub Auto Learn Sensor mode waiting for a device signal

5. Pull the battery tab on the QS5130-840 to power it on. The panel chimes and displays the DL ID. The Source field shows S-Line confirming encrypted enrollment.

6. Touch OK, set Sensor Type to Smoke Detector, choose a Sensor Name, and touch Add New. Sensor Group 26 is assigned automatically. Name the detector by location such as Kitchen Smoke or Bedroom Smoke, then touch Add New.

IQ5 Hub sensor add screen with sensor type dropdown showing smoke detector selected

IQ5 Hub sensor type selection showing Smoke Detector option

After Adding the Detector

Test after enrollment by pressing the test button until the panel sounds a fire alarm. The detector is supervised and always active — it cannot be bypassed. For additional fire coverage, add the IQ Heat 135/200 for fixed-temperature heat detection, or the IQ Carbon for carbon monoxide protection. A monitoring plan ensures fire signals reach the central station for professional dispatch.

Adding the QS5130-840 IQ Smoke and Heat detector to your IQ5 Hub gives you 24-hour encrypted wireless fire protection with no daughter card required on the IQ5 Hub. For help with IQ Smoke and Heat detector enrollment or other configurations or other configurations on your IQ5 Hub, contact the Alarm Grid support team. We are here Monday through Friday from 9:00 AM to 8:00 PM Eastern Time. Email us at support@alarmgrid.com, call us at 888-818-7728, or visit our website and chat with a live support agent.

Did you find this answer useful?

We offer alarm monitoring as low as $10 / month

Click Here to Learn More

Related Products

IQ5 Hub with Verizon LTE - Touchscreen w/PG+ and Z-Wave 800
IQ5 Hub with Verizon LTE
Touchscreen w/PG+ and Z-Wave 800
List Price:
Our Price: $363.99
IQ5 Hub with AT&T LTE - Touchscreen w/PG+ and Z-Wave 800
IQ5 Hub with AT&T LTE
Touchscreen w/PG+ and Z-Wave 800
List Price:
Our Price: $363.99

Related Categories


Answered