Qolsys IQ4 Hub, Verizon LTE, DSC Posts

Posted By

Due to an anomaly with Qolsys IQ panels, this weekend's time change may cause panels to repeat the communicator test excessively. To prevent this, Alarm.com will move the test forward by three (3) hours. This will be a transparent change to customers but offers a unique learning opportunity.

Daylight Savings Time (DST) is one of those things that folks either love or hate. There are those who want to switch to DST permanently. Others think the whole process is a waste of time. Regardless of personal preference, the pervasive nature of DST reminders can serve as a helpful prompt for other important tasks.

For instance, fire departments often encourage people to test their smoke detectors during the time change. This is a convenient opportunity to ensure home safety. Interestingly, not all regions observe DST. Arizona, Hawaii, Guam, Puerto Rico, American Samoa, the Northern Mariana Islands, and the U.S. Virgin Islands do not participate in the "Spring Forward/Fall Back" practice. We encourage residents of these locations and all others to test their smoke detectors this weekend!

The anomaly we mentioned above is fairly straightforward. Any Qolsys IQ Panel that is programmed to send a communication test between midnight and 2:00 am that falls on Saturday night/Sunday morning may send excessive reports when the automatic time change occurs this weekend. For this reason, Alarm.com will automatically move the communication test time for these customers forward by three (3) hours to prevent any issues.

That means if your system usually sends its communication test at 1:00 am, it will now send the report at 4:00 am this coming Sunday and each time the report is sent moving forward. This will be a transparent change for customers. When it comes to communication tests, you're only notified if they don't happen.

When we talk about a "communication test" we're talking about the equivalent of a "dialer test" on a panel that supports a phone line. Alarm systems supervise themselves in all sorts of ways. Individual wireless zones are supervised for check in and tamper, the panel itself has a cover tamper, and the cellular communicator has a supervision interval.

When we activate an account through Alarm.com, we set the communicator on the account for a supervision interval. If the Alarm.com server doesn't hear from the account for the specified supervision interval, a message is generated to the monitoring station and from them to us. We then reach out to the customer to see what's going on. Alarm Grid enables Daily cellular communicator supervision on all central station monitored accounts. Self-monitored accounts are inherently unsupervised.

The communication test that's programmed through the panel is a little different. This test is generated by the panel and helps to verify that the system itself is capable of sending a signal successfully, not just the communicator. By default, the communication test interval is set to weekly through panel programming. It can be set to daily, weekly, or monthly by going to Menu > Settings > Advanced Settings > Installation > Enter Installer Code (1111 by default) > Installer Settings > Communication Test and Communication Test Start Time.

This test, the one programmed through and sent by the panel, is the one that is affected by Daylight Savings Time. Chances are, you don't know whether or not your system is set to send this test. However, it's a good idea to configure it. It will help to verify that the panel is able to send signals through the communicator. As mentioned above, the default communicator test setting is Weekly.

If you don't program a time for the first test report, it will be randomized at the time the panel is either initially programmed at the factory, or when a Master Reset (factory default) occurs. Once the first test is sent, the panel will continue to send the test periodically, either daily, weekly, or monthly thereafter.

The takeaways from the time change are to remember to test your smoke detectors and any other life-safety devices you may have. You should test them at least twice a year, but Alarm Grid recommends monthly testing. And also, give some thought to checking your communication test settings in the Qolsys panel. This is a good automated test to ensure your system is working smoothly. Check out our FAQ on testing the IQ Panel 4.