May 2026 Archives

Posted By

Replacing a First Alert PROA7 or PROA7PLUS panel sounds simple enough. Alarm dealers perform replacements daily using AlarmNet360 (AN360), and when the recommended process is followed, everything works fine. But for a DIYer with no AN360 access, the proper order of things may not be clear.

DIY users often run into a unique problem. While in the process of replacing their existing PROA7 or PROA7PLUS, they also decide to add to the system and purchase new PROSIX sensors for that purpose. The hood's already up, might as well give it a tune up, right?

We've seen customers receive their replacement panel and immediately begin adding new sensors before performing the actual panel swap. We get it, new sensors are exciting! But please curb your enthusiasm until you've worked with one of our support agents to move all existing PROSIX sensors from the old panel to the new one. Otherwise, you may lose either your original PROSIX sensors or the new ones you've already added.

Why This Happens

Unlike older wireless sensors, PROSIX devices become permanently paired, or “married,” to a specific alarm panel during enrollment.

Once a PROSIX sensor is learned into a system, it cannot simply be moved to another panel later unless it is properly released from the original system first.

That means if you:

  • Power up a replacement PROA7 or PROA7PLUS
  • Enroll new PROSIX sensors into it
  • Then later perform a panel replacement in AN360

...you may unintentionally overwrite sensor programming during the restore process.

This can go wrong in any number of ways, but the end result of not following the proper steps is that you lose sensor programming, and the affected sensors may not be recoverable. Once a PROSIX sensor has been paired with a system and powered on for 24 hours or more, it can no longer be factory defaulted. So a sensor in this position, paired with a system that no longer exists with no possibility of being factory defaulted, is a sensor that must be replaced.

But the Panel Does Exist!

Yes...and no. When a PRO Series panel is registered and communicating properly with AlarmNet360, the panel and server stay in constant sync. If programming changes, AN360 updates the panel "image" stored on the server. During a panel replacement, this saved image is transferred to the new PROA7 or PROA7PLUS.

If you get a new panel and begin programming it with new PROSIX sensors, you're creating a new and separate image. One that isn't synced with AN360. When the panel pairs with a PROSIX sensor, it chooses a channel for communication. You may be familiar with this process from older 2.4 GHz WIFI networks. The panel makes its choice based on the least noisy channel at the time of sensor programming. This information becomes part of the new image.

If that channel later becomes noisy, the panel can switch to a cleaner channel and notify all enrolled PROSIX sensors to follow it. If a sensor misses that message, it may remain stuck trying to communicate on the old channel. For more information on PROSIX wireless best practices, check out this FAQ.

The proper channel setting, the encryption key for each PROSIX sensor, and all other panel programming are stored in AN360 as part of the original panel's "image". When you initiate a panel replacement, you're telling AN360 to send the most recent image taken from the old panel to the new one. By necessity, this process replaces the new panel image you began creating when you started adding PROSIX sensors to the new panel prior to the swap. There is no way to merge these two images together.

If the replacement succeeds, the new panel becomes an exact copy of the last synced version of the old panel. That's the intended result. However, if you enrolled new PROSIX sensors into the replacement panel beforehand, those sensors will be overwritten during the replacement process. If they were powered on and paired for more than 24 hours prior to this, they cannot be factory defaulted and will have to be replaced.

The Most Important Rule

If you are replacing a PROA7 or PROA7PLUS system: DO NOT power up or enroll any new PROSIX sensors before the panel replacement is fully completed.

This includes:

Leave any new sensors in the box until the replacement process is completely finished.

The Correct Way to Replace a PROA7 or PROA7PLUS

Follow these steps to avoid losing sensors or corrupting system programming:

  1. Don't power on the new panel. Leave the new panel powered completely down until you are ready to physically replace the old one. Don't perform any programming on the new panel. If you have gotten to this point and you realize you've made the mistake of powering on the new panel and adding PROSIX Sensors, you should factory reset the new panel, then once all PROSIX sensors have received the reset command, power the panel down completely. You can tell a PROSIX sensor has been released if you open or fault the sensor and the LED begins blinking rapidly. If it's going to be hours or days before you can complete the replacement through AN360, remove the batteries from the new PROSIX sensors to conserve power.
  2. If you happen to be replacing your existing panel with a used PROA7 or PROA7PLUS, be sure the "new" panel has the latest firmware. This ensures compatibility with all sensors. After updating, be sure to perform a factory reset before continuing. To do this, the panel will need to be powered on. As long as you complete these steps, then power back down before the swap is initiated in AN360, you're good. You'll need to work with your alarm dealer to arrange the firmware update, if one is needed.

  3. Verify the programming. At this stage, you may want to verify that the "image" of the old panel in AN360 matches the actual programming in the old panel as closely as possible. You'll need to work with your alarm dealer to do this, as end users don't have access to AN360. If the old panel is completely dead, just do your best to complete this step.
  4. Perform the panel replacement in AlarmNet360. Provide the MAC and MAC CRC from the new panel to your alarm dealer. They can now initiate the panel replacement process in AlarmNet360. If you plan to reuse the cellular module, PROWIFIZW*, or any other modules from the existing panel, power it down, remove those modules, and NEVER POWER THAT PANEL ON AGAIN WITHIN RANGE OF THE SENSORS unless your alarm dealer tells you to do so.
  5. *When replacing a PRO Series panel paired with Z-Wave devices, AN360 can bring those devices to the new panel, preventing you from having to exclude and then include them again. However, this is only possible when the PROWIFIZW module from the old panel is moved to the new one.

  6. Allow the replacement process to finish completely. After the replacement has been initiated in AN360, you should:
    • Power up the new PROA7 or PROA7PLUS.
    • Tap the Setup button for WIFI > choose your SSID > enter your password > Save > Connect.
    • Once connected to WIFI, tap Next, then tap Register.
    • Let the new panel fully sync with AlarmNet360. As it goes through the process of adding the existing PROSIX sensors, the panel will chime for each sensor.
    Do not interrupt this process. Depending on signal strength and the number of enrolled sensors, synchronization may take several minutes to complete. Be sure your alarm dealer also knows not to access the account in AN360 until the replacement process has fully finished.
  7. Confirm all existing sensors restored properly. Tap the hamburger menu icon (☰) at the bottom center of the Home screen, then tap Sensors. You should see a list of all enrolled sensors. Verify that the sensor names are correct. To the right of each sensor name, the panel will display the signal strength and battery status of the sensor. Initially, these fields may appear blank. As the panel completes synchronization with the sensors, the signal and battery indicators will gradually populate. The replacement process is not complete until every sensor shows both a valid signal strength and an accurate battery level.
  8. If the old panel was completely dead, or otherwise unable to communicate with the PROSIX sensors for an extended period of time, some sensors may show a low battery condition sooner than expected. PROSIX sensors continuously attempt to check in with the panel. If the panel does not respond, the sensors continue trying repeatedly, which can prematurely drain their batteries. If you suspect that an existing PROSIX sensor may have a dead battery, replace the batteries in the device and make sure it communicates fully with the panel before you enter panel programming.

  9. Add new PROSIX sensors. Only after completing the previous steps should you begin enrolling any newly purchased sensors. Once you have verified that all programming has been synced from AN360 to the new panel, you can add additional sensors and make any other necessary changes.

Final Thoughts

We understand why DIY users try to prepare the new panel ahead of time. It feels like the faster and more organized approach. Unfortunately, with PROA7 and PROA7PLUS systems using PROSIX sensors, doing this can actually create major problems during the replacement process.

The safest approach is simple:

  • Keep the replacement panel powered off.
  • Leave all new PROSIX sensors unopened and unpowered.
  • Work with your alarm dealer to complete the AlarmNet360 replacement first.
  • Verify old sensors restored correctly.
  • Finally, add any new devices and test for proper operation.

Following the proper order prevents lost programming, sensor lockouts, and hours of unnecessary troubleshooting. Alarm Grid customers who need to perform a PROA7, PROA7PLUS, or even VISTAH3 replacement with existing PROSIX sensors should contact support prior to taking any action on the replacement. Our support team is here Monday - Friday from 9:00 AM - 8:00 PM Eastern. You can contact us at 888-818-7728 or by emailing support@alarmgrid.com.

Tags: , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Qolsys has released IQ Panel 5 firmware version 5.0.2 with performance improvements, bug fixes, and upgrades to PGM rules on the entire IQ Panel 5 family. Unlike IQ4 systems, the IQ5 lineup no longer supports local firmware updates through the panel access point and now relies solely on WIFI.

Firmware Updates on IQ4 vs IQ5 Panels

The IQ4 family of panels allows firmware updates to be installed locally using the panel’s built-in access point feature, commonly called Panel AP. This method allowed a user or installer to download the firmware file to a phone or tablet, connect directly to the panel and transfer the file, then install the update.

While this feature was convenient in certain situations, it was seldom used in real-world installations. Most IQ panel firmware updates are performed using WIFI and the panel’s built-in network update tools. Because of this, Qolsys removed local firmware installation support from the IQ Panel 5 family.

This change affects the following systems:

  • IQ Panel 5
  • IQ5 Hub
  • IQ5 NS

These panels can still receive firmware updates directly from Qolsys or Alarm.com using an internet connection, but downloadable firmware files are no longer provided for local installation. However, you can bookmark our IQ5 Family Firmware Update Page for information about future updates.

How to Update IQ Panel 5 Firmware

Before starting the update process, make sure the panel is connected to WIFI and is powered by AC with a charged backup battery. The panel must be on version 5.0.1 before installing 5.0.2. To find the current version, swipe down from the top of the screen, tap Settings > Advanced Settings > Enter Installer Code (default:1111) > About > Tap Software. Verify your panel is on software 5.0.1.

  1. Swipe down from the top of the screen and touch “Settings.”
  2. Tap “Advanced Settings.”
  3. Enter the Installer Code. The default is 1111.
  4. Tap “Upgrade Software.”
  5. Touch “Patch Tag.”
  6. Enter the patch tag: iqpanel5.0.2
  7. Touch “OK.”
  8. Touch “Upgrade Using Network.”
  9. Allow the panel to download and install the update.
  10. When prompted, touch “OK” to reboot the panel.

The software install and reboot process can take several minutes. Do not interact with the touchscreen while the update is being installed.

Using “Upgrade Using Network” Without a Patch Tag

You can also update the panel without entering a patch tag. In many cases, simply selecting “Upgrade Using Network” will allow the panel to contact Qolsys servers and automatically search for available firmware.

However, when a firmware release is very new, Qolsys may initially restrict the automatic update path while the rollout is being staged. During that time, the firmware may only be available by entering the correct patch tag manually.

Once the rollout becomes fully public, the patch tag is usually no longer necessary.

Update Via Alarm.com

For those who are less into Do It Yourself, and more into Do It Together, you can request that your alarm dealer push the firmware update for you using Alarm.com. The Alarm.com server can tell if there are one or more firmware updates available for your panel based on its current version. The server will advise which updates should be installed, and will recommend the proper order, if multiple updates are available.

What’s New in Firmware Version 5.0.2?

Firmware version 5.0.2 includes several fixes and improvements for the IQ Panel 5 family.

  • Fixed an issue where the siren could continue sounding during a Panel Test.
  • Improved IQ Installer App pairing performance with IQ5 systems.
  • Resolved an issue where the panel could reboot while writing health memory data.
  • Updated touchscreen sensitivity calibration.
  • Added updated supervision support for new PGP Heat Detectors, including the PGP9979 and PGP8979.
  • Fixed certain PGM rule behaviors when using compatible W2W and IOG modules.

As with previous Qolsys firmware releases, version 5.0.2 focuses heavily on stability improvements and better long-term reliability for both installers and end users.

If you're an Alarm Grid customer and you need help updating your IQ Panel 5, IQ5 Hub, or IQ5 NS firmware, our support team is happy to assist. You can email us at support@alarmgrid.com or call us at 888-818-8283. Our support hours are Monday through Friday from 9:00 AM to 8:00 PM ET. Please have your panel connected to WIFI before beginning the update process.

Tags: , , , , , , , , , , , , , ,

Comments


Posted By

Resideo recently released a new firmware version for its PRO Series. Firmware 03.2476.204 is now available for PROA7 and PROA7PLUS panels, improving touchscreen response, clarifying the disarm process, and restoring PROSIX signal strength display. Learn more in the official Resideo notice.

Silent Alarm Button Renamed to Police Alarm (Silent)

This is the most important change in the update and it applies to all PRO Series models. In previous versions, during an active alarm, some users were pressing the Panic icon and then pressing the Silent Alarm button to silence the alarm. In reality, what they were doing was sending a silent panic signal, telling central station dispatchers to send the police immediately.

Doing this did silence the alarm, but without warning, police officers were being sent to the address. To make the function clearer, Resideo has renamed the button to POLICE ALARM (SILENT) and provided the instructions to enter a PIN in bold. The behavior is unchanged. But the new description makes it obvious that pressing this button calls the police, and that entering your user code is the correct way to silence an alarm.


Before (left) and after (right) — the Silent Alarm button is now labeled Police Alarm (Silent)

Touchscreen Sensitivity Fix

The touchscreen fix applies specifically to PROA7-FA and PROA7PLUS-FA panels. A small number of these units have experienced inaccuracy or lag when using the touchscreen, and the new firmware adjusts the sensitivity to resolve it. If your panel has felt sluggish or inconsistent to the touch, this update should take care of it. Standard PROA7 and PROA7PLUS models are not affected by this issue, though they can still receive the update.

RFSIX (PROSIX) Signal Strength Display Fix

PROSIX sensors paired with a PRO Series panel show their signal strength, making it easy to confirm they’re communicating properly and to troubleshoot any supervision issues. The display updates daily at 1:00 AM local time, or within about two minutes after using walk test mode.

The third fix addresses an issue that affected some PROA7-FA panels updated to firmware versions 03.2476.174 or 03.2476.183 in August 2025. On those systems, the RFSIX signal strength bar graph could disappear from the screen after the update. This new firmware brings that display back for affected panels. PROA7PLUS-FA and earlier ProSeries models aren’t impacted and don’t require any action. However, it is always recommended to keep your system updated to the latest firmware.

How to Get the Update

The firmware is now available through the AlarmNet360 portal. Alarm dealers can push it remotely to installed panels, or apply it during a new installation if the panel in the box is on an older version. Before the update can be pushed, the panel should:

  • Be disarmed.
  • Be connected to WIFI.
  • Be free of alarm memory.
  • Not have an AC loss condition.
  • Not be actively reporting.
  • Not be in walk test or programming mode.

New PROA7-FA and PROA7PLUS-FA units are already being shipped with 03.2476.204 pre-installed, though it may take a few weeks for all distributor inventory to cycle through. The firmware revision is printed on a label on the side of the box if you want to verify the version before opening a unit.

For help with your PRO Series system, the Alarm Grid support team is available Monday through Friday from 9:00 AM - 8:00 PM Eastern Time. Email us at support@alarmgrid.com, call us at 888-818-7728, or chat with us on our website. Live chat agents are available from 9:00 AM - 6:00 PM Eastern.

Tags: , , , , , , , , , , , , , ,