Qolsys IQ Panel 2 Plus Firmware Version 2.5.4 Has Arrived!

Posted By

We have received word that Qolsys has released Firmware Version 2.5.4 for the IQ Panel 2 and IQ Panel 2 Plus Systems. The main highlights for this latest firmware update include fixes with the Z-Wave S2 Encryption Protocol, plus fixes regarding the use of LiftMaster Garage Door Control.

We do have one thing to mention for users of the Qolsys IQ Panel 2 Solar Integration. If you are using the IQ2 Solar Integration then, DO NOT UPGRADE TO 2.5.4. Instead stay on 2.5.3. However, if you want to use the LiftMaster Garage Door Integration instead of the Solar Integration, then you should upgrade to 2.5.4, but you will LOSE the Solar Integration. On Version 2.5.4, it is IMPOSSIBLE to use BOTH the Solar Integration AND the LiftMaster Integration. Qolsys has said that this will be fixed in Firmware Version 2.6.0, which should hopefully be available in the coming months. For now, if the Solar Integration is more important to you than a LiftMaster Integration, then just STAY ON 2.5.3. This ONLY applies to users of the Solar Integration. If you do not care about the Solar Integration, or if the LiftMaster Integration is more important to you, then UPGRADE TO 2.5.4. All things considered, MOST USERS WILL WANT TO UPGRADE TO 2.5.4. Keep in mind that there is NO WAY TO DOWNGRADE TO A LOWER FIRMWARE VERSION AFTER UPGRADING.

Before we get into all of the exciting new changes for IQ2 Firmware Update 2.5.4, we will first explain how to apply the firmware update to your Qolsys IQ Panel 2 or IQ Panel 2 Plus System. To get started, there are a few prerequisites to keep in mind. Your Qolsys IQ Panel 2 or IQ Panel 2 Plus must be on at least Firmware Version 2.0.1 or higher to apply the update. It must also be connected to WIFI, it should be receiving AC power from its plug-in transformer, and it should not have a low battery condition.

Now, this may get a bit confusing, but stick with us. Depending on which firmware version your IQ2 is currently running, it may be necessary to update in stages to get to 2.5.4. Start by considering which firmware version your system is currently running, and then take the appropriate action(s) based on what is outlined below. The important thing to remember is that your IQ2 must be already on 2.52 or 2.5.3 OR between 2.0.1 and 2.4.2 to upgrade directly to 2.5.4. If that applies to your system, then just go directly to 2.5.4.

For users on Version 2.5.0 or 2.5.1, things become a bit tricky. For these users, you need to upgrade to 2.5.2 or 2.5.3 first before you can get to 2.5.4. We recommend just updating to 2.5.2 and then going to 2.5.4, skipping 2.5.3. For information on updating to Version 2.5.2, please refer to this blog post. Once you are on 2.5.2 or 2.5.3, you can then follow the steps listed below.

Once you are on 2.5.2 or 2.5.3, or between 2.0.1 and 2.4.2, do the following:

  • Start from the main screen of the IQ Panel 2 or IQ Panel 2 Plus.
  • Swipe down the small grey bar at the top.
  • Choose Settings > Advanced Settings.
  • Enter your Installer Code. Remember that this code is 1111 by default.
  • Choose Upgrade Software.
  • Find Patch Tag, and enter iqpanel2.5.4. You must enter the patch tag EXACTLY AS DISPLAYED. Choose OK.
  • Press Upgrade Using Network. If all the requirements have been met, the update will start.

Now, with that out of the way, we can start talking about what's new to 2.5.4. Here is a list of everything you can expect!

  • An issue involving the 6.81.03 Z-wave Firmware Version, also referred to as the 6.81 Z-Wave SDK, has been fixed. The issue caused Schlage Z-Wave Plus Door Locks and the Honeywell T6 PRO Z-Wave Plus Thermostat to not function properly when S2 encryption was used. These devices should now work properly when enrolled using the S2 protocol.
  • Corrections have been made to an issue that arose in Firmware Version 2.5.3 involving the use of LiftMaster Garage Door Control. The integration would not function properly from the panel UI. More information can be found in this document from Qolsys. Also, please see the message regarding the loss of the Solar Integration in 2.5.4 in the notes outlined above.
  • An issue involving the LED status light on PowerG Smoke and Heat Detectors, namely the DSC PG9936, has been fixed. Previously, the status light would not reset after an alarm had been cleared when using Installer Mode or Test Mode on the panel. More information on the issue is available in this document released by Qolsys.
  • The PowerG Radio Firmware has been upgraded to Version 80.34. This upgrade is designed to improve wireless communication, particularly when using multiple DSC PG9WLSHW8 PowerG Wired to Wireless Converter units.
  • Z-Wave Plus 500-Series Z-Wave Switches from Cooper and Eaton are now supported by the IQ Panel 2. The newly supported switches include RF9601, RF9617, RF9640-N, and RF9642-Z.
  • An issue involving PowerG Shock Sensors, namely the DSC PG9935, has been fixed. The issue occurred following a 15 minute placement test mode timeout. There have been further improvements made for false alarm prevention when shock sensors are paired as two (2) separate zones on the system.
  • The 2.5.4 Update now allows PowerG Keypads, namely the DSC WS9LCDWF9, to sound Fire Alarms triggered in other system partitions, provided that the Global Fire Setting is enabled. Please see this FAQ for more information.
  • PowerG Keypads, namely the DSC WS9LCDWF9, can now show special characters on their LCD screens if they are used as part of a Zone Description on the main Qolsys IQ Panel 2 Plus System.
  • The Energy Optimizer for the system is now available locally on the IQ Panel 2. This is used to set Z-Wave thermostats and Z-Wave Plug-In Switches to reduce their energy usage during peak consumption hours. This feature should NOT be used alongside Alarm.com Thermostat Schedules. It is also NOT compatible with the "Give Back, Get Back" program offered by Alarm.com.
  • Certain improvements have been made to the Help Videos as part of the Easy Install Wizard for the system.
  • There have been small changes to facilitate support of Canadian ULC-S304 for Level II Residential and Level II Commercial Listings.
  • A new setting for ULC Commercial Power Restoration is now available.
  • PowerG Image Sensors, namely the DSC PG9934P and DSC PG9944, now take a picture upon the activation of a Fire Alarm or a Carbon Monoxide Alarm, for EU IQ Panel 2 Systems Only. Most United States users will not have this change applied. Furthermore, image sensors learned into Sensor Group 25 will also produce pictures if triggered while the panel is armed.
  • If the EN Grade 2 Security Settings is Enabled, then User Codes will be hidden with dots, rather than showing the entered numeric code.

If you have any questions about Qolsys IQ Panel 2 Firmware Update 2.5.4, or if you are an Alarm Grid monitored customer needing help upgrading to Version 2.5.4, please email us at support@alarmgrid.com for assistance. This email is also good to use if you are interested in starting new monitoring service with Alarm Grid. Our support and planner teams are available from 9am to 8pm ET M-F. We look forward to hearing from you.

Tags: , , , , , , , , , , , , ,

Comments


Related Products

Qolsys IQ Panel 2 Plus Verizon LTE, DSC Compatible - 433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus Verizon LTE, DSC Compatible
433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus - AT&T LTE with PowerG, S-Line & Legacy Interlogix
Qolsys IQ Panel 2 Plus AT&T LTE, Interlogix/GE Compatible
319.5 MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus AT&T LTE, DSC Compatible - 433MHz Wireless Alarm Panel w/ PowerG
Qolsys IQ Panel 2 Plus AT&T LTE, DSC Compatible
433MHz Wireless Alarm Panel w/ PowerG

Related Categories