Qolsys has released IQ Panel 5 firmware version 5.0.2 with performance improvements, bug fixes, and upgrades to PGM rules on the entire IQ Panel 5 family. Unlike IQ4 systems, the IQ5 lineup no longer supports local firmware updates through the panel access point and now relies solely on WIFI.

Firmware Updates on IQ4 vs IQ5 Panels

The IQ4 family of panels allows firmware updates to be installed locally using the panel’s built-in access point feature, commonly called Panel AP. This method allowed a user or installer to download the firmware file to a phone or tablet, connect directly to the panel and transfer the file, then install the update.

While this feature was convenient in certain situations, it was seldom used in real-world installations. Most IQ panel firmware updates are performed using WIFI and the panel’s built-in network update tools. Because of this, Qolsys removed local firmware installation support from the IQ Panel 5 family.

This change affects the following systems:

  • IQ Panel 5
  • IQ5 Hub
  • IQ5 NS

These panels can still receive firmware updates directly from Qolsys or Alarm.com using an internet connection, but downloadable firmware files are no longer provided for local installation. However, you can bookmark our IQ5 Family Firmware Update Page for information about future updates.

How to Update IQ Panel 5 Firmware

Before starting the update process, make sure the panel is connected to WIFI and is powered by AC with a charged backup battery. The panel must be on version 5.0.1 before installing 5.0.2. To find the current version, swipe down from the top of the screen, tap Settings > Advanced Settings > Enter Installer Code (default:1111) > About > Tap Software. Verify your panel is on software 5.0.1.

  1. Swipe down from the top of the screen and touch “Settings.”
  2. Tap “Advanced Settings.”
  3. Enter the Installer Code. The default is 1111.
  4. Tap “Upgrade Software.”
  5. Touch “Patch Tag.”
  6. Enter the patch tag: iqpanel5.0.2
  7. Touch “OK.”
  8. Touch “Upgrade Using Network.”
  9. Allow the panel to download and install the update.
  10. When prompted, touch “OK” to reboot the panel.

The software install and reboot process can take several minutes. Do not interact with the touchscreen while the update is being installed.

Using “Upgrade Using Network” Without a Patch Tag

You can also update the panel without entering a patch tag. In many cases, simply selecting “Upgrade Using Network” will allow the panel to contact Qolsys servers and automatically search for available firmware.

However, when a firmware release is very new, Qolsys may initially restrict the automatic update path while the rollout is being staged. During that time, the firmware may only be available by entering the correct patch tag manually.

Once the rollout becomes fully public, the patch tag is usually no longer necessary.

Update Via Alarm.com

For those who are less into Do It Yourself, and more into Do It Together, you can request that your alarm dealer push the firmware update for you using Alarm.com. The Alarm.com server can tell if there are one or more firmware updates available for your panel based on its current version. The server will advise which updates should be installed, and will recommend the proper order, if multiple updates are available.

What’s New in Firmware Version 5.0.2?

Firmware version 5.0.2 includes several fixes and improvements for the IQ Panel 5 family.

  • Fixed an issue where the siren could continue sounding during a Panel Test.
  • Improved IQ Installer App pairing performance with IQ5 systems.
  • Resolved an issue where the panel could reboot while writing health memory data.
  • Updated touchscreen sensitivity calibration.
  • Added updated supervision support for new PGP Heat Detectors, including the PGP9979 and PGP8979.
  • Fixed certain PGM rule behaviors when using compatible W2W and IOG modules.

As with previous Qolsys firmware releases, version 5.0.2 focuses heavily on stability improvements and better long-term reliability for both installers and end users.

If you're an Alarm Grid customer and you need help updating your IQ Panel 5, IQ5 Hub, or IQ5 NS firmware, our support team is happy to assist. You can email us at support@alarmgrid.com or call us at 888-818-8283. Our support hours are Monday through Friday from 9:00 AM to 8:00 PM ET. Please have your panel connected to WIFI before beginning the update process.

Tags: , , , , , , , , , , , , , ,

Comments


Posted By

Firmware updates keep your 2GIG GC Touch panel running smoothly while adding new features and improving current ones. The latest update introduces enhanced usability, new customization options, and system improvements that help ensure continued reliable performance from your security system.

A firmware update is available for the 2GIG GC Touch, available in AT&T LTE and Verizon LTE versions. In this post we're talking about Version 1.1, displayed on the panel as ROM 1.1.072. To check your current firmware version, go to Settings (⚙️), enter your Installer Code (1561 by default), and navigate to the System Information screen. Scroll down until you see the Software Version. After completing the update, the panel will reflect the new version number as noted above, confirming that the firmware has been successfully installed.

Removed the Enter Requirement for PIN Codes

"And the people said, Amen!" One of the most noticeable usability improvements, and my personal favorite, is that you no longer need to press the Enter (↵) button after entering a user code. The GC Touch now automatically accepts valid 4-digit or 6-digit codes, depending on your system's settings, once entered. This streamlines everyday interactions like arming and disarming the system, making operation faster and less cumbersome for users.

Sensor Chime Voice Annunciation

This update introduces voice annunciation for sensor chimes. Instead of relying solely on a chime tone, the panel can now audibly announce sensor activity. This gives the user clearer awareness of which door or window has been opened, improving situational awareness throughout the home without requiring you to look at the panel screen. A sensor can use chime tones or voice description, but not both.

30-Minute Sounder Disable for Testing

A new option allows users or installers to temporarily disable the panel sounder for up to 30 minutes. This is especially useful during system testing or maintenance, since it prevents repeated alarm sirens while allowing you to verify sensor functionality. It makes troubleshooting and walk testing far more convenient and less disruptive for children, pets, and you! To disable the sounder, from the Home Screen tap Settings (⚙️) > Enter Installer Code (default: 1561) > Equipment Management > Disable Sounder.


OTA Firmware Update Requests from the Panel

Version 1.1 also lays the groundwork for easier updates in the future by adding the ability to request over the air updates directly through the panel. While updates are still managed and distributed via Alarm.com, this feature streamlines the update process, reduces reliance on manual USB updates, and minimizes the need to contact your alarm dealer for firmware updates.

Screen Saver and Photo Slideshow

A highly anticipated addition is the new screen saver and photo slideshow feature. The GC Touch can now display images when idle, allowing it to function as a digital picture frame. This adds a more personalized touch to the panel and helps it blend more naturally into the home environment. If you need help configuring this new feature, check out our FAQ on the subject.

Repeater Supervision Support

Finally, the update also introduces repeater supervision support. This allows the panel to monitor compatible repeaters and confirm that they remain operational. By supervising these devices, the system can maintain strong and reliable communication with wireless sensors throughout the property.

Keeping your 2GIG GC Touch up to date ensures you get the best performance, features, and reliability from your system. If you need help updating your panel or have questions about these new features, contact the Alarm Grid support team. Call us at 888-818-7728, email support@alarmgrid.com, or visit www.alarmgrid.com to chat with a live agent. Support is available Monday - Friday from 9:00 AM to 8:00 PM Eastern Time, with chat available from 9:00 AM to 6:00 PM Eastern Time.

Tags: , , , , , , , , , , , , , ,

Comments


Posted By

Resideo recently announced that its VISTA and PRO Series panels are now fully certified to integrate with Control4 whole-home automation. Control4 is a premium automation platform, typically available only through authorized Control4 integrators, and it operates by using specialized drivers

Control4 drivers act as the essential software that enables communication between the Control4 automation system and various third-party devices. A certified Control4 driver allows for seamless integration and centralized control of different smart home products through the Control4 interface. The interface can be a touchscreen, an app, or even voice commands. For homeowners and installers, this means a unified experience where security, lighting, entertainment, and more can be managed from a single platform.

For homeowners, the benefits are clear. A certified integration allows the Resideo First Alert panel to do more than just secure the home, it becomes part of a larger ecosystem. Using Control4, you can arm the alarm system at night while having the doors lock automatically, the thermostat adjust to an energy-saving setting, and the lights dim across the house. That’s the type of seamless, one-touch automation that Control4 is known for, now enhanced with the proven reliability of a Resideo First Alert security system.

For dealers and installers, certification reduces guesswork and support headaches. Instead of relying on custom workarounds, they can now use official drivers that are tested and verified. This not only speeds up installation but also builds dealer confidence, by knowing their installations are backed by two major industry players working together.

The move also positions Resideo strongly in the high-end automation space. By joining the ranks of other security systems officially supported by Control4, VISTA and PRO Series panels are now a more compelling option for projects where premium automation is a requirement. It’s a win for integrators looking to expand their offerings, and a win for homeowners looking to unite all of their tech through a single interface.

VISTA panels use the 4232CBM Connected Building Module to integrate with Control4. The module connects the VISTA panel's ECP bus to the Control4 system through a wired serial RS232 or RS422 interface. This setup allows the Control4 driver to import zone alpha descriptors directly from the VISTA panel, which eliminates the need for manual programming of zone data within Control4. As a result, users can arm, disarm, and monitor the status of zones directly through the Control4 interface. Check out the 4232CBM Install Guide.

Another plus that shouldn't be overlooked is the fact that Control4 will import life-safety zones and descriptors. This allows an integrator to create automations based on fire or carbon monoxide zone triggers. For example, in the event of a fire alarm the system might automatically turn off the HVAC system and unlock the doors while turning on lights that illuminate a path out of the building.

Control4 and First Alert PRO Series Integration

You can find the steps for integrating the PRO Series panels with Control4 here. Here's a quick overview of what you'll need:

Before You Begin:

  • Control4 OS 4.1.0+ and Composer Pro Software.
  • PRO Series Firmware 03.2476.183+
  • PRO Series panel must have a PROWIFI or PROWIFIZW installed.
  • PRO Series panel should have all its partitions and zones configured before pairing with Control4, though you can add or remove zones after initial configuration.
  • Your alarm dealer must enable the Control4 feature through AlarmNet360. This is done as part of the Smart Home package (Packages > Smart Home > Add-Ons > Control4).
  • The Control4 system and the PRO Series panel must be connected to the same network through the same router.

After configuration with Control4’s Simple Service Discovery Protocol (SDDP), the PRO Series panel must always use the same IP address. SDDP is a lightweight protocol created by Control4 that lets WIFI enabled devices announce themselves on the network, making it easy for Control4 to find and identify them.

If the panel’s IP address changes, it will disconnect from Control4. Because setting a static IP directly on the alarm panel can be tricky, the better option is to reserve an IP address for the PRO Series panel in your router’s DHCP settings. Check your router’s documentation for instructions on how to set this up. Below is a list of names for this feature, and which manufacturers use each term:

  • DHCP Reservation – Netgear, ASUS, TP-Link (most common term)
  • Address Reservation – D-Link
  • IP Reservation – Linksys, Spectrum, Xfinity
  • Reserved IP Address – Some ISP-provided routers (AT&T, Verizon)

Basic Steps For Setup:

  1. Initiate discovery. From Control4 Composer Pro, initiate discovery (System Design > Items > Discovered).
  2. Create association. Double click on the PRO Series driver that you discovered in Step 1. If Composer Pro fails to discover the driver, make sure that all the prerequisites listed above have been met. Once the driver has been discovered and you double click, the driver is downloaded to your Control4 system. The panel's IP and other required information is sent to Composer Pro. The driver and the IP address can then be associated with one another within Composer Pro.
  3. Perform pairing. Within Composer Pro, click Actions > Start Pairing. You have 120 seconds to complete the next step. If two minutes elapse without a successful pairing, the process will timeout and you'll need to perform this step again.
  4. Pair PRO Series panel. On the PRO Series panel, tap Menu (≡) > Tools > Enter Installer Code (4112 by default) > Control4 Controller > Pair to Control4 Controller. When Composer Pro receives the pairing command, it will know, based on the panel's IP address, to associate the PRO Series driver with the panel and complete the pairing process. If the pairing is successful, the Control4 Controller information will automatically populate. If pairing fails this field will remain blank. In that case, verify that all of the requirements in "Before You Begin" have been met, and try again.

Complete Integration:

  1. Verify partition import. In Composer Pro select Properties. Partition information will be displayed here as the information is imported. Upon successful import, the partition state will update from "Unknown" to the current state. This process may take a minute, so please be patient. Verify that all partitions, along with proper status, are displayed in the left pane.
  2. Import and verify zone information. From Advanced Properties within Composer Pro select Get C4 Contacts to update and display individual PRO Series zones with proper status. The zones will also show in the left pane. When a zone is added (or removed), it will show which zones have been added or deleted there.
  3. Verify visibility. From a Control4 touchscreen, or the Control4 app, tap Security and verify that all partitions and zones are displayed. If a partition appears to be missing, check the visibility settings for that partition within Composer Pro:
    • In the left pane select PRO Series > Properties > Navigator.
    • Select Security in the navigator menu. This will display the Device Visibility settings. Partitions are either "Visible" or "Hidden". If any partition that should be visible within Control4 is listed as hidden choose the Modify option and move that partition from Hidden to Visible.
    • Click File > Refresh Navigators to update and display all partitions. Any partition that remains listed as hidden will not display on any Control4 touchscreen or within the Control4 app. Presumably, it will also remain hidden to any voice assistant you may be using.
  4. Test integration. Once the previous steps have been completed successfully, use the Control4 touchscreen or app to verify operation and status. Verify that all partitions show the proper status, i.e., Armed, Disarmed, etc. Walk around and fault zones, i.e., open and close doors, walk in front of motion detectors, etc. and verify that the status updates within the touchscreen or app.