Honeywell Home PROA7PLUS101A Posts

Posted By

AlarmNet360 is both a website and an app that can be used to create, edit, and cancel AlarmNet accounts. Access to this website and app is only available for licensed alarm dealers who are affiliated with AlarmNet. As an end-user you will not need to have or create an AlarmNet360 account.

Being a DIYer in the alarm industry can be pretty confusing at times! Nearly all of the documentation provided with alarm systems that have historically been installed only by alarm professionals is intended only for alarm professionals. So, when you buy that new ProSeries or Lyric Alarm System, and you begin reading the installation instructions, one of the first things you are told to do is create an AlarmNet360 account. This is not something that you, as a DIYer will be able to do.

This is where Alarm Grid comes in. Alarm Grid is a DIY friendly company. We sell professional grade alarm systems to anyone who wants to buy them. Sometimes, alarm professionals purchase from us and then they go about configuring the system themselves because they have access to AlarmNet360. Sometimes, customers purchase from us and then hire their own alarm professional to install their system and that alarm professional completes the setup on AlarmNet360 themselves. But usually, when an individual buys a system from us, they then sign up for one of our no-contract monitoring plans, and then we set up their account through AlarmNet360.

The relationship between Alarm Grid and our monitoring customers is a symbiotic one. DIY alarm users choose not to pay a professional to do something that they can do themselves. That being the physical installation of the alarm equipment. With the proliferation of self-contained, all-in-one systems, installation has gotten more and more simple. A child can do it. We have several young customers in their teens who set up systems just because they enjoy doing it, and figuring out new and interesting ways to make things happen.

On the monitoring side of things, that's where restrictions start to come in. There are certain things that have not opened up to DIYers yet, and access to AlarmNet360 is one of those things. You may be thinking, "Forget AlarmNet360, what's AlarmNet?" You can read about AlarmNet here. At present, only alarm dealers can sign up for access to AlarmNet360 in order to be able to add, edit, or cancel AlarmNet accounts. Access to accounts is very tightly controlled. The only accounts that Alarm Grid can see in AlarmNet360 are accounts that are assigned to Alarm Grid, which usually means that Alarm Grid created them in the first place.

Alarm Grid chose the DIY business model in part because we have everything we need to administer accounts on the back end, but we don't have a team of installers to send out and put in systems. DIYers are our installers, and in turn we provide for them the account admin services that they are not allowed to perform for themselves. We sell reasonably priced, professional grade alarm equipment. The same equipment that just about any alarm dealer in the country will sell you, and we handle the administrative side of things, in addition to providing free, world-class technical support to our monitored customers. In exchange for that, we charge a reasonable monitoring fee with no activation fees, no cancellation fees, and no contracts. We also don't care if you buy your system from us or elsewhere. We will monitor any equipment that is within our power to monitor for the same prices we charge to monitor the equipment we sell.

So, when you crack open that new system, and start reading the instructions, skip the part where it talks about the AlarmNet360 account. Whoever you sign up for monitoring with will take care of that part. Do you have an AlarmNet communicator? Have you been stumped by the mention of AlarmNet360 in your system's documentation? Leave us a comment below and let us know if this information was helpful. We always look forward to hearing from you.

Tags: , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

After much waiting and anticipation, Resideo has delivered the firmware update we have all been wanting for ProSeries Panels. ProSeries System Update Version 3.591.92.0 for PROA7PLUS, PROA7PLUSC, PROA7, and PROA7C introduces local programming mode, as well as other system enhancements.

First, we want to cover how to receive the update. Only monitored ProSeries Systems can be updated. You must have your ProSeries System online and connected with the AlarmNet servers in order for the over-the-air (OTA) update to go through successfully. The system must be connected with a WIFI network, as the update cannot be sent across cellular. Remember that while the PROA7PLUS and PROA7PLUSC both come with integrated WIFI network cards, the PROA7 and PROA7C can only connect to WIFI if a PROWIFIZW or PROWIFI has been added separately.

As a one-time event Alarm Grid is planning to send down the new firmware update to all its monitored customers with ProSeries Panels sometime in the coming days. This OTA update is being done in one mass shot to try to update as many users as possible all at once. No special action should be required on your part. Just have your ProSeries Panel powered on and connected to WIFI. While this process isn't perfect, and there will inevitably be some users who miss out on the update for one reason or another, this is the best way for us to ensure that as many end-users as possible have their panels updated. Remember, we can only update ProSeries Systems that are actively monitored by Alarm Grid. If you have a different monitoring provider, then ask them to help you update your system.

If your automatic OTA update fails for whatever reason, or if you didn't have your panel ready at the time of the mass OTA update, then you can request that the update be sent down manually. Alarm Grid customers can email support@alarmgrid.com to request a manual OTA update. Please make sure that you have your ProSeries Panel powered on and connected to WIFI when we push down the OTA update, or else the update process will fail. Our support hours run from 9 am to 8 pm ET M-F, so keep that in mind when contacting us. Furthermore, we cannot push down a manual OTA update to your panel if you receive alarm monitoring service from a different provider. If you are monitored by a different company, then you should instead reach out to your provider for further assistance.

There are some big highlights here in ProSeries Firmware Update 3.591.92.0. Obviously, the elephant in the room is the introduction of local programming mode. Previously, users were forced to have all system programming completed remotely by their monitoring provider. This included basic system setup tasks like enrolling sensors and configuring zone settings. Not only will the introduction of local programming make activations easier for professional technicians, but it will also empower end-users and give them greater control over their systems. This is a huge deal, as it officially makes the ProSeries Panels DIY-friendly alarm systems.

There are other major introductions in ProSeries Firmware Update 3.591.92.0, though they are likely to be overshadowed by the introduction of local programming. Nonetheless, we are still very excited about these smaller, but still important, introductions. For one, there is a boost to system partitioning, as a common lobby partition option is now available. You can set Partition 3 or Partition 4 as the common lobby, depending on how many partitions are being used. The highest number partition will always be the common lobby, and you must have at least 3 partitions in order to enable the common lobby feature.

There are some principles to keep in mind regarding the lobby function. You cannot set both Partition 3 and Partition 4 as the common lobby. Only one can be the common lobby partition at any given time. The way that the common lobby partition works is that disarming any other partition will also disarm the common lobby partition. Additionally, if ALL other partitions are armed, then the common lobby will also automatically arm. The only way you can arm/disarm the common lobby partition independently is if all the other system partitions are in an armed state. All system users have authority over the common lobby partition. Finally, any 24-hour zones assigned to the common lobby partition will sound on keypads of all partitions, but you can only silence alarms and troubles from these zones using the common partition keypad. Any faulted zone in the common lobby partition will be automatically bypassed when the common lobby partition is armed, even if it is armed automatically due to all other partitions being armed.

The ProSeries Firmware Update 3.591.92.0 brings support for some upcoming PROSiX Sensors that we hope to have available on our site very soon. Specifically, we are talking about support for the PROSiX Wireless Repeater (PROSIXRPTR) and support for the PROSiX Wireless Heat (PROSIXHEAT).

A local alarm mode is now supported, meaning you can trigger a localized system alarm, complete with siren, but without the system reporting out. This can be good for scaring away on-site intruders, while also resting easy in knowing that the authorities will not be sent to the premises. This is basically how the system behaves if an intrusion alarm occurs on a system that is not being monitored. When local alarm mode is enabled, all communication to AlarmNet is halted, including access to Total Connect 2.0 features.

The panel will now provide severe weather alerts. This feature requires that the system is set up with Total Connect 2.0 and the corresponding weather package. Remember, this is only possible if the system is monitored and set up with Total Connect 2.0. Ask your monitoring company about receiving weather alerts on the panel.

If you are using the system in Canada, you can now use the PROTLE-CN Communicator. This communicator may be carried by Alarm Grid in the future. Alarm Grid is not provided with the option to sell the Resideo and Honeywell Home lineup of Canadian communicators, however, we can get potential customers in touch with a Canadian distributor. Once you obtain a PROLTE-CN elsewhere, then we will be able to set it up for monitoring.

On the PROA7PLUS and PROA7PLUSC only, you can now stream the live video feed for Total Connect 2.0 IP Cameras and SkyBell Video Doorbell Cameras from both the Panel, as well as any PROWLTOUCH or PROWLTOUCHC Keypad. The PROA7PLUS and PROA7PLUSC also now both support disarm photos from the PROWLTOUCH and PROWLTOUCHC Keypads. Again, these two (2) features are for use with the PROA7PLUS and PROA7PLUSC only.

For all ProSeries Panels, there is backlight timeout improvement. You can now set the backlight timeout for a ProSeries Panel or a PROWLTOUCH/PROWLTOUCHC Keypad to Disable and have the screen go completely dark. This is instead of going to the "inactivity screen" that shows the weather, time & date, 1st thermostat temperature, partition arming status, panic icons, and CELL/WIFI/AC/BLE status.

Other updates include:

  • You can now have Partition 1 Disarm automatically when a Z-Wave Door Lock is UNLOCKED.
  • There are improvements to the 7-Day Z-Wave Thermostat Schedule on Total Connect 2.0.
  • There is now optional device supervision for PROWLTOUCH & PROWLTOUCHC Keypads.
  • The PROSIX Wireless Technology is now more accurate in displaying signal strength and remaining battery life.
  • There is now improvement in enrollment range for PROSIXSMOKEV and PROSIXHEATV.
  • There is now improved multi-language display on the PROSIXLCDKP Keypads.
  • If you use a cellular communicator in Canada then you may notice Cellular Roaming Improvement.
  • Updates to the ProSeries Cyber Security.
  • The PROINDMV Indoor Motion Viewer and Z-Wave Devices are now supported during the AlarmNet360 Panel Replacement Process. This is only for the PROA7PLUS and PROA7PLUSC.

Are you excited about this new update? What do you think about local programming finally being available for the ProSeries Panels. Is there some other new feature that you're also really eager to check out. Let us know in a comment down below. And stay tuned to the Alarm Grid Blog for more news and updates coming soon.

Tags: , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted

We are thrilled to announce that new Alarm Grid System Kits featuring the Honeywell Home PROA7PLUS System are now available! We have twelve (12) kits in total, split into four (4) main categories, with options available for users in most situations. They're ready for your home or business!


UPDATE:

As of Firmware Version 3.591.92.0, the Honeywell Home PRO Series panels all support local programming through the keypad. You can read full details about this exciting firmware update here.

If you aren't familiar with the PROA7PLUS, then we strongly recommend reviewing this introduction post and buying guide, as it will really help you get acquainted with the latest Resideo Security System. For this post, we mainly want to focus on the new kits, so that is what we will do.

Potential buyers should keep in mind that the PROA7PLUS does NOT support local end user programming at this time, though we have received word from Resideo that the feature is coming. And while we do not have a firm answer on Apple HomeKit compatibility, we suspect that HomeKit support will be coming later down the pipeline. Remember that the Honeywell Lyric and its system kits DO support local end user programming and Apple HomeKit, so that can be a really good alternative if you don't want to wait for Resideo to get their system ready.

With that out of the way, here are the kits! Like we said earlier, there are four (4) distinct categories, with three (3) system kit options in each category. Basically, in each category, you are choosing an IP-only option OR a dual-path IP & LTE cellular option with either AT&T OR Verizon. Find the category that makes the most sense for you, and then choose - IP-only, Dual-Path AT&T & IP, or Dual-Path Verizon & IP.

Remember that if you go dual-path, you will need a monitoring plan with cellular connectivity, such as an Alarm Grid Gold or Platinum Level Plan (Self or Full). We always recommend the use of cellular backup, as it is the only way to keep your system connected for monitoring service in the event of an internet outage. But whether you ultimately go with IP-only or dual-path is up to you. As a reference, the cellular communicator options for the PROA7PLUS are the PROLTE-A (AT&T LTE) and the PROLTE-V (Verizon LTE). And make sure that your monitoring plan includes access to Total Connect 2.0 if you want to control the PROA7PLUS System remotely from your phone or a web browser!

The first category we have is our 3-1 PROA7PLUS Kits. These include the PROA7PLUS System, three (3) PROSIXMINI2 Door and Window Sensors, one (1) PROSIXPIR Motion Sensor, and a Honeywell LT-Cable. These are great for smaller homes and apartments where only a few sensors are needed.

Next, we have our 10-1 PROA7PLUS Kits. These include the PROA7PLUS System, ten (10) PROSIXMINI2 Door and Window Sensors, one (1) PROSIXPIR Motion Sensor, and a Honeywell LT-Cable. These are great for larger homes and businesses where many sensors are needed.

Then, we have our Wired Upgrade PROA7PLUS Kits. These include the PROA7PLUS System, a PROSIXC2W Wired to Wireless Converter, and two (2) Honeywell LT-Cables. These are great if you are upgrading to the PROA7PLUS from a wired alarm system, and you want to keep using your existing hardwired sensors.

Last, we have our Wireless Upgrade PROA7PLUS Kits. These include the PROA7PLUS System, a PROTAKEOVER Legacy RF Receiver Module, an a Honeywell LT-Cable. These are great if you are upgrading to the PROA7PLUS from a wireless alarm system, and you want to keep using your existing compatible wireless sensors.

Like always, if you have any questions about compatibility, or if you are interested in signing-up for new monitoring service, then please email us at support@alarmgrid.com. We are here to help you from 9am to 8pm ET M-F. We look forward to hearing from you and helping you get started with your new PROA7PLUS Alarm Panel!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments