It's the first Alarm Grid video recap of September! We have some great new videos to show you, and we're hopeful that you find them helpful in setting up your system. Subscribe to our YouTube channel if you haven't yet, and stay tuned for future videos. Let's check out the newest videos.


Using a Qolsys IQ Panel 2 with a Phone Line

I explain how you cannot use the Qolsys IQ Panel 2 with a phone line connection. Phone line connectivity was once the most common communication path used with security systems. But with the rise of internet and cellular, that is no longer the case. Most newer panels like the IQ Panel 2 don't even have a jack for using a phone line. Instead, the system has built-in WIFI and cellular. Remember that activating for monitoring service with use of Alarm.com requires the activation of the system's cellular communicator.


Removing a Z Wave Device from a Qolsys IQ Panel 2

I show you how to remove, or clear, a Z-Wave device from the network by using a Qolsys IQ Panel 2 Plus. Clearing a Z-Wave device is typically done before enrolling it with the network to ensure that all the network data is properly wiped out. It is also done if the user no longer intends on using the Z-Wave device anymore. It is important to note that a device can still be cleared from the network even if it isn't actively enrolled with a Z-Wave hub.


Program SiXCT to Lyric Controller

I show you how to program a Honeywell SiXCT Door and Window Contact Sensor to a Honeywell Lyric Alarm System. The Honeywell SiXCT is a wireless door and window sensor that uses 128-bit AES encryption for enhanced wireless security. The sensor has a terminal block so that you can use it as a wireless transmitter with a wired contact sensor. The wireless range for the SiXCT is roughly 300 nominal feet, and it has a green LED light to assist with enrollment.


Program SiXMINICT to Lyric Controller

I show you how to program a Honeywell SiXMINICT to a Honeywell Lyric Alarm System. The SiXMINICT is a smaller version of the SiXCT. Unlike the SiXCT, the Honeywell SiXMINICT does not have a terminal block, and the sensor cannot be used as a wireless transmitter. It also has a smaller wireless signal range of only about 200 nominal feet. However, this door and window sensor is smaller than the SiXCT, and many users prefer the more compact design of the SiXMINICT. It retains the same green LED light to assist with enrollment.


Program a Honeywell SiXGB to the Lyric Security System

I show you how to program a Honeywell SiXGB Glass Break Sensor to a Honeywell Lyric Security System. As a member of the Honeywell SiX Series Lineup, the SiXGB utilizes 128-bit AES encryption, and it can only be used with the Lyric System. The wireless glass break sensor actively listens for the sound of breaking glass. It is great for monitoring windows and protective glass casings. The sensor has a detection range of roughly 25 feet, and it needs a direct line of sight to any glass being monitored.


Adding an External Communicator to a DSC PowerSeries NEO

I show you how to install an external communicator for a DSC PowerSeries NEO Security System. The PowerSeries NEO requires an added communicator for connecting with Alarm.com. The communicator connects with the DSC PCL-422 Module, which comes included. Then, a PC-Link cable connection is made between the NEO Panel and the PCL-422. Once the communicator is properly installed, you will need to activate it for monitoring service. Remember that you will need a monitoring plan that offers cellular communication.

Tags: , , , , ,

Comments


Posted By

If you're using a newer wireless security system, then you will definitely want to explore the encrypted sensor options that we offer! Encrypted sensors are virtually impossible to hack, and they can make your security system even more secure. There are many great options available.

Honeywell sixminictpk5 a 5 pack of sixminict encrypted wireless

As you know, a home security system or a business security system is an investment you make for the protection of yourself, your property, and those around you. A proper system should also give you peace of mind and make you feel safe. It doesn't do you any good if an intruder manages to defeat your system. But with encrypted sensors, that is extremely unlikely to ever happen.

If you aren't familiar with encryption, it refers to techniques for encoding data and signals so that only authorized individuals and/or equipment are able to access the information. When it comes to wireless alarm systems, encrypted sensors send protected signals that can only be accessed, received, and interpreted by the authorized panel.

When wireless systems first rose to prominence, they rarely, if ever, used encryption. This made many people wary of wireless security panels, and they felt more secure using wired ones. The lack of encryption wasn't seen as a fatal flaw, as an intruder would have to be extremely savvy and really know what they're doing to defeat even a non-encrypted sensor. To this day, many people feel totally comfortable and safe using non-encrypted equipment. Remember, most intruders don't have the knowledge to beat wireless sensors, even if they aren't using encryption.

But there are the rare, professional criminals who do take the time to extensively study security equipment, and they develop techniques for beating non-encrypted devices. This is very uncommon, but it's not unheard of. And if you aren't using encrypted sensors, then you are leaving yourself open to this small risk. Whether or not that means outfitting your system with all-new encrypted sensors, or even upgrading to a different system that is capable of supporting encrypted sensors is up to you. We just want to make you aware of your options.

Today, we're going to briefly look at some popular wireless systems and explore their encrypted sensor options, as well as their non-encrypted sensor lineups. This will help you learn more about your system, or one you are considering for purchase.


Honeywell Lyric Controller

Honeywell lyric controller encrypted wireless security system


The Lyric represents the first the first encrypted panel from Resideo, formerly known as Honeywell. The system has its very own lineup of encrypted sensors called the Honeywell SiX Series Sensors. The lineup is a bit limited, as its lacking options like an outdoor door and window sensor and a curtain motion sensor. But the good news is that these sensors are extremely secure with their military grade 128-bit AES encryption.

You can supplement your SiX Series Sensors on your Lyric System with devices from the Honeywell 5800 Series. These sensors are not encrypted, but the lineup offers more diverse selection than the SiX Series lineup. You could consider using encrypted sensors for the most vulnerable parts of your home or office, while using non-encrypted 5800 Series devices for areas where it isn't as important. The non-encrypted 2GIG 345 MHz Sensors are also compatible with the Lyric once the system is on Firmware Version MR3 or higher.


Qolsys IQ Panel 2 Plus

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy


There are some outstanding encryption options available for the Qolsys IQ Panel 2 Plus, regardless of which version you have. Any IQ Panel 2 Plus System can readily support DSC PowerG Sensors. Not only do these sensors have an outstanding wireless range of up to 2,000 feet away from the IQ Panel 2 Plus, they also utilize military grade 128-bit AES encryption and Frequency Hopping Spread Spectrum (FHSS) technology.

And if you have the 319.5 MHz Version of the Qolsys IQ Panel 2 Plus, then you can also pair Qolsys S-Line Sensors, which use rolling code encryption. This rolling code encryption isn't quite as secure as the encryption used by PowerG Sensors, but it still does a good job of keeping your system protected. The S-Line Sensors will also utilize encryption when paired with the original Qolsys IQ Panel 2. The original IQ Panel 2 cannot use PowerG Sensors.

In terms of non-encrypted options, each IQ Panel 2 Plus can support one of three (3) non-encrypted radio frequency signals. The available options are 319.5 MHz, 345 MHz, and 433 MHz, and it is dependent upon which version of the IQ Panel 2 Plus you buy. Again, it is certainly possible to mix encrypted sensors with non-encrypted sensors on the same system. But with the diversity and selection of the PowerG lineup, you probably won't need to look outside too much.


2GIG GC3e

2gig gc3e wireless encrypted alarm panel


The big highlight when the 2GIG GC3e was introduced was its ability to support encrypted sensors. While it took a little while before its encrypted sensor lineup became available, we were very pleased with the result. The 2GIG eSeries Sensors use highly secure encryption to keep your system protected. It also seems that 2GIG is regularly expanding upon this lineup, as we have been seeing new eSeries Sensors hit the market it recent times. All of the 2GIG eSeries Sensors are compatible with the GC3e, as well as its little brother, the GC2e.

With the GC3e, you also get access to the Honeywell 5800 Sensors and the 2GIG 345 MHz lineup. Just like with the Lyric, there is a bit more of a diverse selection of non-encrypted sensors available for the 2GIG GC3e. You can definitely set up a mixture of encrypted and non-encrypted sensors to meet the needs of your business. But with new 2GIG eSeries offerings continuing to become available, you shouldn't have much trouble building a fully encrypted 2GIG Security System.


Alarm grid inside security stickers

If you are looking to set up an encrypted security system, then Alarm Grid is here to help! We can let you know if your existing system has any encrypted sensor options available. We can also help you determine if you are currently using encrypted devices or if your existing sensors are non-encrypted. Many users have trouble determining. Either way, we'll help you make an informed decision so that you can get the most out of your monitoring service. If you want to reach us, please email support@alarmgrid.com. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Alarm Grid is here with another video recap. We're got some informative videos to help you set up and use your security system. Remember to subscribe to our YouTube channel and stay tuned for future videos and other great content. Let's check out the latest tutorial videos from Alarm Grid.


Program SiXPIR to Lyric Controller

I show you how to program a Honeywell SiXPIR with a Honeywell Lyric Alarm System. The Honeywell SiXPIR is a wireless motion detection sensor designed exclusively for use with the Lyric Security System. The sensor responds to changes in infrared energy caused by movement. The SiXPIR has a maximum coverage area of (40) by (56) feet when mounted from a recommended height of (7.5) feet. It supports pet immunity for small animals weighing up to (80) pounds.


Enroll DSC PG9303 to IQ Panel 2 Plus

I show you the process for manually enrolling the DSC PG9303 PowerG Door and Window Contact Sensor with the Qolsys IQ Panel 2 Plus. Manual enrollment refers to the practice of manually entering in the sensor's Serial Number, rather than allowing it to automatically generate through auto-enrollment. Manual enrollment is recommended for the PG9303 if auto-enrollment fails. After manually enrolling, you must activate the sensor's tamper cover to complete the enrollment process. Activating the tamper cover confirms the encryption key that is shared between the sensor and the panel.

Tags: , , , ,

Comments


Posted By

While checking out Firmware Version 2.5.3 for the Qolsys IQ Panel 2 Plus, we came across the Smart Energy Optimizer feature, and we figured we'd take a closer look. From what we can tell, this feature looks to be a nice way to set up automation rules for lighting devices right from the IQ2.



As you can see from the above picture, the option is found conveniently within the Settings Menu for the system. Simply click on the small grey bar at the top of the screen, and then choose Settings. You should see the Smart Energy Optimizer option with the Tree icon in the bottom-left corner. In order to enter this menu, you must have at least one compatible Z-Wave device enrolled with the system. If you try to enter the menu without a Z-Wave device being enrolled, then you will not gain access.

Once you are in the menu, you can set compatible lights to turn ON/OFF or to DIM to a set level during peak hours that you can set on the panel. You can set both the month and the hour of the day when "peak" consumption goes into effect for energy savings. You can also choose whether the automatic adjustments will only be applied to weekends (Saturday and Sunday). It's all customizable. We're sure Qolsys is going to continue developing this feature.


Based on the settings we have shown above, our light is set to automatically DIM to a 52% level between the months of June to September, during the hours of 2pm to 5pm, with the weekends set as the peak. Of course, you can set your compatible light or dimmer switch however you want. The time setting is expressed in 24-hour "military time", so keep that in mind when setting your values. For our testing, we used the Qolsys IQ Dimmer. The dimmer level bar is a bit flimsy and difficult to adjust, so we're hoping Qolsys makes it a bit easier to control in a future update. But for now, 52% is close enough to half-level that we're happy.

We're still exploring the feature, so we'll let you know if we find out anything else. For now though, it looks like a nifty little way that you can automate your smart lights directly from your Qolsys IQ Panel 2 Plus System! If you have any questions about the feature, or if you want to learn more about alarm monitoring, send an email to support@alarmgrid.com. We're here to check email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , ,

Comments


Posted By

After much anticipation Firmware Version 2.5.3 for the Qolsys IQ Panel 2 Plus is now available! This update brings support for the PowerG Wired to Wireless Converter, as well as some other new features. Everyone with an IQ Panel 2 is encouraged to download the update as soon as possible.

Qolsys iq panel 2 plus verizon lte with powerg s line and legacy

Support for the DSC PG9WLSHW8 PowerG Wired to Wireless Converter is the biggest new addition for Firmware Version 2.5.3. We covered the PowerG Wired to Wireless Converter extensively in a post last month. But just as a quick recap, the device allows to you to connect hardwired sensors so that they can communicate with the IQ Panel 2 Plus wirelessly across the PowerG protocol. This is an excellent way to upgrade from an older hardwired system, as it can prevent you from having to purchase entirely new wireless sensors.

The PG9WLSHW8 also includes all the benefits of PowerG. This includes a wireless range of up to 2,000 feet away from the IQ2+ in an open air environment, military grade 128-bit AES encryption, and Frequency Hopping Spread Spectrum (FHSS) technology for added protection. Up to eight (8) hardwired zones are built into a single converter, and you can use up to two (2) of the PG9WLSHW8 units per IQ2+ System. The unit even offers support for 2-wire or 4-wire smoke detectors, plus a 700mA supervised output for adding a wired siren.


Of course, IQ Panel 2 Firmware Version 2.5.3 includes a huge bundle of other new features and functions. Even if you don't plan on adding a DSC PG9WLSHW8 unit, there are still many other reasons to receive the upgrade. We'll touch on all the other new additions below.

The IQ2 system now has Panel Ambient Noise Detector settings to adjust noise threshold and duration. Qolsys added this feature with MDU settings where noise complaints are a concern. The feature can be used in-place of the panel's built-in glass break sensor. Alarm.com is planning to add back-end support for this feature sometime in the future.

Alarm.com commercial customers will be able to take advantage of their Smarter Business Temperature Monitoring (SBTM) service plan, which is used in conjunction with the DSC PG9905 PowerG Temperature Sensor. The SBTM service plan allows for 24/7 monitoring, real-time alerts, and historical temperature reporting. It is designed with businesses like restaurants, grocery stores, and pharmacies in mind. Alarm Grid customers with Alarm.com commercial accounts can contact us for more information. In addition, the IQ2+ can now display a trouble condition when an external probe is disconnected from the DSC PG9905.


If you use Alarm.com for solar energy monitoring, then you will be pleased to know that IQ Panel 2 Firmware Version 2.5.3 offers the ability to provide information from your solar inverter right on your security panel! Solar inverter units from SolarEdge and Enphase are supported. Please see this prior blog post for more info about Alarm.com Solar Monitoring.

Thinking ahead, Qolsys has made Firmware Version 2.5.3 compatible with future Z-Wave 700-Series daughter cards. The 700-Series of Z-Wave will represent the successor to Z-Wave Plus, also known as the Z-Wave 500-Series. Like all new iterations of Z-Wave technology, the 700-Series will allow for extended range and battery life when used with a compatible Z-Wave controller or hub. We hope to see 700-Series Z-Wave devices enter the market sometime in the not-so-distant future. Qolsys also made improvements to the IQ2 Z-Wave Diagnostics Map when using the Z-Wave 6.81 SDK to include RSSI values, as well as the ability to move automation device on the Diagnostics Map.

Some new 500-Series Z-Wave Plus devices are now supported by the IQ Panel 2. Most notably, these include Z-Wave switches from Eaton. Newly supported models include the RF9601, RF9617, RF9640-N, and RF9642-Z. It's good to see Qolsys increasing their support of compatible Z-Wave devices, and we have heard particularly nice things about the Z-Wave switches from Eaton and Cooper.

You can now disarm from the main IQ Panel 2 during the Exit Delay if the arming session was initiated from an IQ Remote, PowerG Keypad, or key fob device. Qolsys also added three (3) new Sensor Groups for keypads, key fobs, and panic switches. These new Sensor Groups include (3) Mobile Silent, (5) Fixed Silent Auxiliary, and (7) Mobile Silent Auxiliary. These new Sensor Group options should add some more versatility for these devices. And as for the Qolsys IQ Remote Keypad, it now has the ability to pair with IP routers using the Protected Management Frame (PMF) protocol.

Qolsys iq remote ag iq panel 2 remote touchscreen keypad

There are some new changes to the Easy Install Wizard that loads upon booting up the system for the first time. A new drop-down option will allow you to select one of (13) languages for the setup wizard. There is also a new page in the wizard with QR links for you to scan using the camera on your Android or iOS phone to quickly download the Alarm.com Mobile App. Also added to the Easy Install Wizard are new help screens that provide more information on how to pair and test door and window contacts and motion detection sensors.

Some general improvements to the system's PowerG firmware have also been bundled with Firmware Update 2.5.3. The PowerG Modem Firmware is now Version 2.38. There is now support for Fire Trouble and Dirty Detector Trouble on the IQ2 and ADC when DSC PG9936 PowerG Smoke Detectors are used. Proximity tag support is now supported with the Visonic PowerG Wireless Keypads (models KP141 and KP241). And the Alarm.com back end can now show the "Not Networked" status for PowerG Sensors in the Event History. This occurs when a PowerG device is enrolled with the panel, but then fails to complete the network association and goes into RF sensor failure.

There are also some changes affecting certain PowerG Door and Window Contact Sensors. For the DSC PG9309 and DSC PG9312, both the reed switch and the auxiliary input can be disabled during disarm. The same also applies to the auxiliary input on the DSC PG9945. The purpose of this is to extend the battery life on high traffic doors. Additionally, the PG9945 and PG9309 can be learned-in with the IQ2+ twice. One zone will be for the sensor's internal reed switch, which the other will be used with the auxiliary input.

Dsc pg9945 powerg 915mhz wireless door slash window contact


Other miscellaneous features have been added as well. LiveAnswer is now supported on the IQ2 for security cameras with non-standard aspect ratio streaming. New languages of German, Danish, Portuguese, Hungarian, and Romanian have all been added to the IQ Panel 2. The IQ2 will also now provide audible and visual indication of dual-path failures when the EN Grade 2 Setting is enabled. A change to the Swinger Shutdown feature has been made so that once a sensor reaches its Swinger Shutdown limit, a subsequent sensor event will tell the IQ2 to send an event notice to Alarm.com. Lastly, various improvements to the system have been made so that the IQ2 meets the EN50131-1 Standard.

Now that we have covered all of the new features included with Firmware Version 2.5.3, we can cover the process for upgrading your IQ Panel 2. Qolsys did things a little bit different this time. In order to download 2.5.3, your IQ Panel 2 or IQ Panel 2 Plus must be running a firmware version between 2.0.1 and 2.4.2. Do not attempt to download 2.5.3 if your IQ Panel 2 is running Firmware Version 2.5.0 or 2.5.1. If your IQ2 is on one of those firmware versions, then you must upgrade in stages by upgrading to Firmware Version 2.5.2 first, and then upgrading to Version 2.5.3. More information on upgrading to 2.5.2 can be found here.

If you need to check the firmware version for your panel, click the small grey bar at the top of the screen, and choose Settings > Advanced Settings > enter Installer Code (default 1111) > About > Software. You should see the firmware version displayed. The panel in the picture below is already on 2.5.3.


Once your IQ2 is on a firmware version of 2.0.1 to 2.4.2, or is on Firmware Version 2.5.2, then you can begin upgrading the Qolsys IQ Panel 2 Firmware Version 2.5.3. To begin, make sure your panel is monitored and connected with the Alarm.com servers via WIFI. The panel should be plugged into its AC outlet, and it should not have a low-battery condition.

When ready, you can perform the update by clicking the small grey bar at the top of the screen and selecting Settings > Advanced Settings > Installer Code (default 1111) > Upgrade Software > Patch Tag > enter iqpanel2.5.3 > OK > Upgrade Using Network. Then press OK when prompted. It will take about five (5) minutes for the update process to complete. The panel will reboot as part of the update process.

If you have any questions about the Qolsys IQ Panel 2 Plus, please reach out to us. Also remember to check out this post to learn more about our monitoring plans for gaining access to Alarm.com. The best way to contact us with questions about the IQ Panel 2 System or alarm monitoring in general is to email support@alarmgrid.com. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , ,

Comments


Posted By

Alarm Grid is back with another video recap! This time, we have six (6) new videos to share. We spent a lot of time this week focusing on the 2GIG GC3e, but we also covered some other security equipment as well. We hope you enjoy this latest batch of videos. Let's check them out!

Alarm grid inside security stickers

Properly Opening Up a 2GIG GC3e

I show you how to open up the 2GIG GC3e Security Panel. Before opening the system, you must loosen the set screw at the bottom. If the panel is wall-mounted, you can press the panel against the wall and lift upward. Otherwise, lay the panel face-down, and pop off the back plate using your finger or a screwdriver. Opening up the GC3e Panel is often done to access the system's terminal block and backup battery.


Powering On the 2GIG GC3e

I show you how to power on the 2GIG GC3e Alarm System. The system uses a 14VDC, 1.7A transformer for primary power. If primary power is lost, then a backup battery will keep the system running. When powering on the 2GIG GC3e, we recommend connecting the backup battery first, followed by the transformer. Alarm wiring is not included with the 2GIG GC3e, so you must supply your own. We recommend using a Honeywell LT-Cable for this purpose.


Deleting a Defective Z-Wave Device from the GC3 or GC3e

I show you how to delete a defective Z-Wave device from a 2GIG GC3 or 2GIG GC3e. Some reasons why a Z-Wave device might be displayed as failed include the device being powered down or out of wireless range. Deleting a defective Z-Wave device is usually a good option if the device is lost or destroyed so that a traditional exclusion process cannot be performed. Any failed Z-Wave device will have an error icon next to it in the Smart Home Devices Menu.


Setting Up a Cellular Communicator for a 2GIG GC3e

I show you how to add a cellular communicator to a 2GIG GC3e Security System. Doing this will allow you to activate the 2GIG GC3e System for monitoring service. And if the monitoring plan includes access to Alarm.com, then you will also be able to control the system remotely through that platform. The 2GIG GC3e has a side slot for you to easily install a cellular radio. Remember to power down the system completely before installing the cellular communicator.


Powering the TG-1 Express Using the On-Board Terminals

I show you how you can power the Telguard TG-1 Express using its on-board power terminals. The Telguard TG-1 Express is used to take over the phone dialer for a panel so that it can communicate across a cellular network. Normally, the TG-1 uses a single RJ31X connection for power and communication with the panel. But if the existing power wires from the RJ31X cable are cut, then you can instead make the auxiliary power connections at the TG-1 on-board terminals.


Properly Closing the Qolsys IQ Panel 2

I show you how to properly close the Qolsys IQ Panel 2 Security System. To properly close the system, you want to align the top tabs first. Then you should lock the bottom two (2) tabs into place. Lastly, make sure the top four (4) tabs remain closed, and click them into place if they are not. The panel will make a strange noise every half-hour if it is not closed properly. The main reason to open the IQ2 is to replace its backup battery every few years.

Tags: , , , , , , , , , , , , , , , , ,

Comments


Posted By

It's time for another video recap! There are eight (8) new videos this week, all featuring yours truly. We spent a lot of time working on the 2GIG GC2e again. We also covered the process for backdooring the Honeywell LYNX Touch Panels, and we touched on the IQ2+. Let's check out the videos!

Alarm grid inside security stickers

Pairing a Z-Wave Device with the 2GIG GC2e

I show you how to pair a Z-Wave device with a 2GIG GC2e Security System. The 2GIG GC2e serves as a Z-Wave Plus controller, which allows you to pair smart home automation devices with the system. Devices can be controlled locally at the panel, as well as remotely from Alarm.com if the system is monitored. There are many types of Z-Wave devices you can use with the GC2e, including lights, door locks, smart thermostats, and more!


Programming a Wireless Zone On a 2GIG GC2e

I show you how to program a wireless zone for a 2GIG GC2e Alarm System. Every sensor used with the 2GIG GC2e will take up at least one zone. The GC2e System has sixty (60) wireless zones available. You can pair sensors from the Honeywell 5800 Series, the 2GIG 345 MHz Series, and the 2GIG eSeries Lineup. We recommend auto-enrolling any new sensor to prevent entering an incorrect Serial Number. Auto-enrolling will also confirm successful communication.


Programming a Key Fob for a 2GIG GC2e

I show you how to program a key fob for a 2GIG GC2e Alarm Panel. A key fob is a small, handheld device that you can use to arm and disarm your system. You can very easily carry around a key fob in your pocket or purse, and they are great for putting on key rings. Popular key fob options for the 2GIG GC2e System include the 2GIG KEY2-345, the 2GIG KEY2e-345, and the Honeywell 5834-4.


Adding & Changing User Codes On a 2GIG GC2e

I show you how to add and change user codes on a 2GIG GC3 Security Panel. The GC2e has (64) user code slots available. You need a valid user code to successfully disarm the system. It is recommended that everyone who uses the system regularly has their own user code so that you can keep track of who uses the system. You can also apply a schedule to a code so that it only works at certain times.


Using the Backdoor to Enter Programming On a Honeywell L5200 or L5210

I show you how to use the backdoor method on a Honeywell L5200 or L5210. The backdoor method involves rebooting the panel and then performing a special sequence of commands as the system reloads. By completing this process, you can get into programming if you were previously locked out. Please note that the backdooring process will not work if the system is currently in an armed state. You will need to disarm the system before you can backdoor.


Getting Back Into Programming On an L7000 If You're Locked Out

I show you how to get into programming on a Honeywell L7000 if you're locked out by using the backdoor method. There are two (2) main reasons why you would become locked out of programming. The first is that the option "NO" was selected at the prompt asking if the installer should be allowed to re-enter programming. Always choose "YES" when exiting programming. The other possibility is that you do not know the Installer Code for the system. Do not change the Installer Code from its default of 4112 to avoid being locked out.


Secure Arming On the Qolsys IQ Panel 2 Plus

I demonstrate the Secure Arming feature on the Qolsys IQ Panel 2 Plus. When Secure Arming is enabled, you must enter a valid user code or the Master Code when arming the system. Normally, the system can be armed without providing a code. Additionally, you must also provide a code if you go to cancel an arming session during the Exit Delay countdown if this feature is enabled. Many parents with small children enable the feature to prevent the system from being armed accidentally.


IQ Panel 2 Exit Delay Increased After Opening Door

I explain why the Exit Delay timer on the Qolsys IQ Panel 2 Plus will automatically increase after opening a door. This is due to a false alarm prevention feature called Auto Exit Time Extension. This feature is activated if two (2) Entry/Exit faults are detected during the Exit Delay countdown. When you fault the first E/E Zone after arming, the system assumes that you have left the building. Then when another E/E fault is detected, the system assumes that you have returned. It then gives you an added 60 seconds to exit the building. If you quickly re-entered the premises because you forgot something, this prevents you from having to disarm and then re-arm the system.

Tags: , , , , , , , , , , , , , , , , ,

Comments


Posted By

We're here with another video recap! There are eight (8) new videos for you to check out this week. Once again, I took the role of appearing in all the videos. We hope to have some familiar faces returning soon! But for now, let's take a look at what our video team has been up to.

Alarm grid inside security stickers

Deleting a Wireless Zone from a Simon XT

I show you how to delete a wireless zone from a Simon XT Security System. The Simon XT uses 319.5 MHz wireless sensors, and it has forty (40) zone slots available. By accessing the Sensors Menu of Programming, you can delete any wireless zone that has been set up with the system. You can then enroll a new sensor in that open zone slot if needed. Keep in mind that the zone must be rebuilt from scratch if you decide to re-add the sensor back to the system.


Deleting a Wireless Zone from a Simon XTi or Simon XTi-5

I show you how to delete a wireless zone from a Simon XTi or Simon XTi-5. The Simon XTi and Simon XTi-5 are essentially the same as the Simon XT, except for the fact that these two panels have built-in touchscreen keypad. Both the Simon XTi and Simon XTi-5 have forty (40) available wireless zones, and they both use 319.5 MHz wireless sensors. If you delete a zone from the Simon XTi or Simon XTi-5, then you can reuse the zone with a new sensor.


Disabling Exit Sounds on a Qolsys IQ Panel 2 or IQ Panel 2 Plus

I show you how to disable Exit Delay sounds on the Qolsys IQ Panel 2 Plus. The IQ2 makes Exit Delay sounds for false alarm prevention. The idea is that if you accidentally Arm Away the system, then the Exit Delay sounds will alert you to the situation so that you know to either leave the building or cancel the arming session. But if you find Exit Delay sounds to be bothersome or annoying, there are a couple of different options for muting these sounds.


Cover Tamper Causes the Qolsys IQ Panel 2 to Make Strange Noises

I explain why the Qolsys IQ Panel 2 will make an usual noise every thirty (30) minutes. The reason why this happens is because the panel is not positioned on its back mounting plate properly. It can be a bit tricky to get the panel on the back plate properly, but once you do, the sound should stop occurring. If you absolutely cannot get the panel positioned on the back plate, then you do have the option of disabling tamper cover notifications in programming.


Manually Extending the Exit Delay Time On IQ2

I show you how to manually extend the Exit Delay countdown time on the Qolsys IQ Panel 2 for a single arming session. When you Arm Away on the IQ2, the Exit Delay timer will go into effect. You must then leave the building or cancel the arming session within the exit delay time limit. If you press the green +60 button, then the Exit Delay will be extended by sixty (60) seconds. You can only do this once per arming session. Pressing the button again will do nothing.


Permanently Extending the Exit Delay Time On IQ2

I show you how to permanently extend the Exit Delay countdown time on the Qolsys IQ Panel 2. By permanently extending the Exit Delay, you will have a longer amount of time to vacate the building every time you Arm. The system will use either the Normal Exit Delay setting or the Long Exit Delay setting depending on what zones you have programmed with the system. If you have at least one zone with Sensor Group 12 - Entry/Exit Long Delay, then the system will use the Long Exit Delay setting.


Installing a Honeywell 7847i on a VISTA P-Series Alarm Panel

I show you how to install a Honeywell 7847i on a VISTA P-Series Security System. The Honeywell 7847i is an IP communicator that allows a compatible panel to connect with the Resideo AlarmNet Servers for monitoring service. If you want to use Total Connect 2.0 with your system, then you must be running Firmware Version 9.12 or higher on a VISTA-15P or VISTA-20P. You can determine the firmware by checking the PROM Chip. No version of the VISTA-10P will work with Total Connect 2.0.


Installing a Honeywell 7847i On a VISTA TURBO Panel

I show you how to install a Honeywell 7847i on a Honeywell VISTA TURBO Panel, such as a Honeywell VISTA-128BPT or a Honeywell VISTA-250BPT. The most common reason why someone will choose to use an IP-only communicator is because they want monitoring costs to be as low as possible. IP monitoring is less expensive than cellular monitoring because no cellular service fees are incurred. But keep in mind that an internet outage will take your panel offline if you rely strictly on IP communication for your system.

Tags: , , , , , , , , , , , , ,

Comments


Posted By

It's Monday again, and it's time for another Alarm Grid video recap! We have six (6) new videos for you. Five (5) feature the DSC PowerSeries NEO, while the last one covers the Honeywell LTE-IA and LTE-IV Communicators for VISTA Systems. All videos feature yours truly. Let's check them out!

Alarm grid inside security stickers

Adding a DSC HS2TCHP Touchscreen Keypad to a DSC PowerSeries NEO

I show you how to add a DSC HS2TCHP Touchscreen Keypad to a DSC PowerSeries NEO Security System. Adding a touchscreen keypad like the DSC HS2TCHP to a system can be more inviting and easier for end users to understand than a traditional numeric keypad. The DSC HS2TCHP connects with the same on-board panel terminals as any other keypad for the system. Remember to power down your NEO Panel completely before adding a keypad or making any other hardware changes.


Adding Hardwired Zone to DSC PowerSeries NEO Security System

I show you how to add a wired sensor to a DSC PowerSeries NEO Security System. As a hardwired alarm panel, the DSC PowerSeries NEO can used wired sensors with no extra add-ons being required. All wired zones on the NEO will use end of line 5.6k ohm resistors, which are color coded green-blue-red-gold. This includes wired zones that are not actively being used with the system. New wired sensors will be connected with the panel, and the appropriate Zone Definition will be set at the corresponding zone.


Program a Wireless Zone to a DSC PowerSeries NEO

I show you how to add a wireless sensor to a DSC PowerSeries NEO Security System. The NEO cannot support wireless sensors right out of the box. Instead, a wireless transceiver must be added to the system. The NEO supports PowerG Transceivers that will allow you to use PowerG Wireless Sensors with the system. The advantage to using wireless sensors is that they are much easier to install than wired sensors. This is because you will not need to run wires for wireless sensors.


Enrolling a PowerG Sensor to a DSC PowerSeries NEO

I show you how to add a PowerG Sensor to a DSC PowerSeries NEO Security System. This will require that a PowerG Transceiver is added to the system, such as a DSC HS2LCDRF9 N Keypad or a DSC HSMHOST9 Standalone Transceiver. PowerG Sensors are widely seen as some of the best wireless sensors in the security industry. This is because these sensors offer a wireless signal range of up to 2km in an open air environment, and they utilize military grade 128-bit AES encryption for exceptional security.


Delete a Zone From a DSC PowerSeries NEO

I show you how to delete a zone from a DSC PowerSeries NEO. This process differs depending on whether the zone is wireless or hardwired. For a wireless zone, you are clearing the sensor from the system so that it is no longer recognized. For a wired zone, you are merely changing the Zone Definition for the associated wired zone to [000] for Null Zone. Deleting a zone from a DSC PowerSeries NEO will open up the zone so that it can be used with a different sensor.


Installing a Honeywell LTE-IA or LTE-IV Communicator to a VISTA-21iP System

I show you how to add a Honeywell LTE-IA or a Honeywell LTE-IV to a Honeywell VISTA-21iP Security System. The LTE-IA and the LTE-IV are dual-path communicators that use both IP connectivity (wired ethernet) and LTE cellular connectivity. When adding one of these communicators to a VISTA-21iP, you must first disable the internal IP communicator for the system. This is done by re-positioning the white jumper to the bottom two (2) prongs. Make sure to power down the panel before re-positioning the jumper and installing the communicator!

Tags: , , , , , , , , , , , ,

Comments


Posted By

We have heard reports lately of RF supervision troubles on 2GIG GC2e and 2GIG GC3e Systems, particularly for zones set up with encrypted 2GIG eSeries Sensors. Upon further testing, we have learned that eSeries Zones configured with incorrect Equipment Codes can cause supervision trouble.

2gig pir1e wireless encrypted pir motion detector

Equipment Codes are somewhat of a unique quirk for 2GIG Security Systems. This numeric code identifies the model number of the wireless sensor that is being used. It should not be confused with the sensor's Serial Number, which is unique for each individual sensor. You set the Equipment Code when programming a new zone. Alarm Grid has helpful guides available for programming a GC2e zone and programming a GC3e zone.

The following table contains the current list of eSeries Equipment Codes:

Product Name Equipment Code
2GIG eSeries Smoke Detector (USA) 2058
2GIG eSeries CO Detector (USA) 2860
2GIG eSeries Tilt Sensor 2061
2GIG eSeries Flood Sensor 2065
2GIG eSeries Shock Sensor 2066
2GIG eSeries Repeater 2067
2GIG eSeries Translator 2068
2GIG eSeries Water Sensor 2070
2GIG eSeries Thin Door/Window Contact 2862
2GIG eSeries Recessed Door Contact 2863
2GIG eSeries Glass Break Detector 2864
2GIG eSeries Pet-Immune PIR Motion Sensor 2869
2GIG eSeries Takeover Module 2873
2GIG eSeries 4-Button Keyfob Remote 2866

Before the rise of 2GIG eSeries Encrypted Sensors, the Equipment Code setting on a 2GIG System was largely seen as a formality. The general practice was to find the corresponding sensor if available, but generally not worry about it very much if you couldn't match it exactly. Some third-party sensors do not have their own Equipment Codes, and an "equivalent" is usually selected instead. For example, the Honeywell 5800MINI and the VERSA-2GIG can both just use the Equipment Code for "Existing Door/Window Contact", rather than finding an exact match.

But for the 2GIG eSeries Sensors, the Equipment Code selection is actually very important. Failing to set the exact corresponding equipment code can result in the system displaying an RF supervision loss trouble condition for the associated zone. This trouble is typically used to identify that the system has lost communication with the sensor, due to either the sensor powering down from a dead or missing battery, or the sensor being taken out of wireless range. But it seems that the GC2e and GC3e cannot properly supervise a 2GIG eSeries Sensor with an improper Equipment Code. More information can be found in this FAQ.

Missing Equipment Codes are more common for third-party sensors not produced by 2GIG. For a 2GIG Sensor, you should almost always have a direct Equipment Code selection available. And the 2GIG eSeries Sensors are still quite new, so 2GIG made sure to put in Equipment Codes specifically for each of these sensors. However, you may be unable to find an Equipment Code for a brand-new eSeries Sensor if your 2GIG System isn't on the latest firmware version. Adding support for new sensors is a major part of most 2GIG Firmware Updates. You can view our GC2e Firmware Page here, and our GC3e Firmware Page here.

If you need any help programming a GC2e or GC3e wireless zone, then make sure to check out the programming FAQs we linked earlier. Alarm Grid monitored customers can also receive additional free support by emailing support@alarmgrid.com. This is also a great email to use if you are interested in signing up for new monitoring service. We check our email from 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , , , , , , , ,

Comments