A great way to build out your Honeywell Lyric is with Honeywell 5800 Sensors. These are simple, 345 MHz wireless sensors that you can easily enroll with the system for security, life-safety, and environmental monitoring. They are perfect for expanding your system and making it more robust.

Honeywell lyric controller encrypted wireless security system

When you want to pair a Honeywell 5800 Sensor with the Lyric, the process is very straightforward. Put the Lyric in its auto-enrollment mode by choosing Security > Tools > enter Installer Code (default 4112) > Program > Zones > Add New > Serial Number. Make sure the RF Type on the right-hand side is set to 5800. Then activate the sensor either by faulting it or triggering its cover tamper switch. The Lyric should beep to confirm that it received a signal transmission. Then activate the sensor a second time to have the Lyric display the Serial Number. The third activation will confirm the Serial Number and return you to the screen where you can configure the zone settings.


Programming the zone settings for the sensor is actually quite simple. Depending on how you enrolled the sensor, you may need to adjust the Loop Number. This is almost always the case if you enrolled the sensor by activating its tamper switch. Refer to the instruction manual for the 5800 Sensor to determine which Loop Number to use.

The two (2) Zone Descriptors and the Device Type serve as the name for the sensor. You should choose a name that will help you identify the sensor, e.g. "Front Bedroom Motion Sensor", "South Hallway Door", etc. The Response Type determines how the system responds when the sensor is faulted. See our list of Lyric Response Types for more info.

Alarm Report should be set to Yes if you want the system to report out through AlarmNet to a Central Station if the zone causes an alarm on the system. That is an essential component of alarm monitoring services. Chime is optional, and it has the panel emit any one of several available sounds when the zone is faulted. Supervision tells the panel to look for an RF check-in signal from the sensor periodically to ensure that it is online. Click Save in the bottom-right after you finish adjusting the settings.


Keep in mind that only uni-directional (one-way) sensors from the Honeywell 5800 Series can be used with the Lyric. This leaves out bi-directional devices like the Honeywell 5800WAVE Siren, the Honeywell 5828 Keypad, and the Honeywell 5800RL Relay Module, so make sure you do not buy those for the Lyric. But you still have a lot of excellent sensors and security devices to choose from.

Below is a list of the Honeywell 5800 Sensors that you can use with the Honeywell Lyric:

Sensor Name
Notes
Honeywell 5800MINI
Honeywell 5800mini interior wireless door and window sensor
Door/Window sensor. Uses Loop 1.
Honeywell 5800PIR-RES
Honeywell 5800pir res wireless pet immune motion detector close up
PIR motion sensor. Uses Loop 1.
Coverage Area: 35' x 40'
Honeywell 5816
Honeywell 5816 wireless door window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5811
Honeywell 5811 wireless wafer thin door and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5800C2W
Honeywell 5800c2w hardwire to wireless system 9 zone conversion module
9-zone wired to wireless converter. Allows hardwired sensors to communicate with the Lyric as wireless devices. All zones use Loop 1 and a unique Serial Number ID.
Honeywell 5800CO
Honeywell 5800co wireless carbon monoxide detector
Carbon monoxide sensor.
Loop 1 = CO Detection
Loop 2 = End of Sensor Life (separate programming only required on TURBO and other V-Plex panels)
Honeywell 5800COMBO
Honeywell 5800combo smoke heat and co detector
Combination, smoke, heat, CO, and low-temperature sensor. Uses up to five (5) zones on the Lyric Panel. Has two (2) Serial Numbers for enrollment purposes.
Loop 1, SN 1 = Smoke/Heat Detection
Loop 2, SN 1 = Smoke/Heat Maintenance
Loop 3, SN 1 = Low Temperature Detection
Loop 1, SN 2 = CO Detection
Loop 2, SN 2 = End of Sensor Life (separate programming required only on TURBO and other V-Plex panels)
Honeywell 5800FLOOD
Honeywell 5800flood wireless flood and temperature sensor
Flood and temperature sensor.
Loop 1 = Low Temperature Detection
Loop 2 = High Temperature Detection
Loop 3 = Flood Detection
Honeywell 5800MICRA
Honeywell 5800micra wireless recessed window contact
Recessed window sensor. Uses Loop 1.
Honeywell 5800PIR
Honeywell 5800pir exterior of wireless motion detector
PIR motion sensor.
Loop 1 = Low Sensitivity Motion.
Loop 2 = High Sensitivity Motion.
Loop 3 = Low Temperature Detection
Coverage Area: 35' x 40'
Honeywell 5800PIR-COM
Honeywell 5800pir com exterior of wireless long range motion det
Commercial PIR motion sensor.
Loop 1 = Low Sensitivity Motion
Loop 2 = High Sensitivity Motion
Loop 3 = Low Temperature Detection
Coverage Area: 60' x 80'
Honeywell 5800PIR-OD
Honeywell 5800pir od wireless outdoor motion detector exterior
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800PIR-OD2
Outdoor PIR motion sensor. Uses Loop 1.
Honeywell 5800RP
Honeywell 5800rp wireless repeater
Wireless repeater for Honeywell 5800 Sensors. Does not require enrollment, but can be assigned a single zone for RF supervision, low-battery, AC loss, and RF jam detection. This is done using Serial Number 1 with Loop 1, with DIP Switch 2 set in the OFF position. Can also use up to four (4) separate zones for supervision when DIP Switch 2 is set to ON. This is required for UL installations.
Honeywell 5800RPS
Honeywell 5800rps wireless recessed door and window plunger sens
Recessed door/window sensor. Uses Loop 1.
Honeywell 5800SS1
Honeywell 5800ss1 exterior of wireless shock sensor
Shock sensor. Uses Loop 1.
Honeywell 5802MN
Honeywell 5802 wireless panic button
Medical alert button. Uses Loop 1.
Honeywell 5802MN2
Honeywell 5802mn2 wireless dual button medical alert
Medical alert button. Uses Loop 1.
Honeywell 5802WXT
Honeywell 5802wxt wireless panic button
Panic button. Uses Loop 1.
Honeywell 5802WXT-2
Honeywell 5802wxt 2 wireless dual button medical alert
Panic button. Uses Loop 1.
Honeywell 5806W3
Honeywell 5806w3 wireless smoke detector
Smoke detector. Uses Loop 1.
Honeywell 5808W3
Honeywell 5808w3 wireless smoke and heat detector
Smoke and heat detector.
Loop 1 = Smoke & Heat Detection
Loop 3 = Low Temperature Detection
Honeywell 5809
Honeywell 5809 wireless heat detector
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit, or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5809FXT
Honeywell 5809 wireless heat detector
Fixed temperature heat detector. Uses Loop 1. Alarm occurs when the temperature exceeds 135 degrees Fahrenheit.
Honeywell 5809SS
Honeywell 5809ss wireless fixed temperature slash ror heat detec
Fixed temperature and rate-of-rise heat detector. Uses Loop 1. Alarm occurs at 135 degrees Fahrenheit or when the temperature rises more than 15 degrees Fahrenheit per minute.
Honeywell 5814
Honeywell 5814 wireless small door sensor and window sensor
Door and window sensor. Uses Loop 1.
Honeywell 5815
Honeywell 5815 white wireless aesthetic door sensor and window s
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5816MN
Honeywell 5816mn wireless mini door sensor and window sensor
Door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switches
Honeywell 5816OD
Honeywell 5816od wireless outdoor door and window sensor top
Outdoor door and window sensor.
Loop 1 = Terminal Block for NC Contact
Loop 2 = Reed Switch
Honeywell 5817
Honeywell 5817 wireless three zone sensor
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised. It does not use an End of Line Resistor (EOLR)
Loop 2, 3 = NC Only. Both are unsupervised with no EOLR used
Honeywell 5817CBXT
Honeywell 5817cb wireless commercial sensor
Three (3) zone commercial transmitter.
Loop 1 = Two (2) Terminals; Primary Loop supervised by 470k Ohm (yellow, purple, yellow, gold) EOLR. Resistor must ALWAYS be installed, even if Loop 1 is not programmed. If Loop 1 is used as a burglary zone, then Loop 4 must be programmed as a separate zone for Cover Tamper protection.
Loop 2 = NC Reed Switch
Loop 3 = Two (2) Terminals; NC Loop unsupervised, no EOLR required
Honeywell 5817XT
Honeywell 5817xt three zone universal transmitter
Three (3) zone door and window sensor & transmitter.
Loop 1 = NC or NO (DIP Switch Selectable) unsupervised with no EOLR required
Loop 2, 3 = Two (2) Terminal Blocks, NC Only
Honeywell 5818MNL
Honeywell 5818mnl wireless recessed door sensor and window senso
Recessed door and window sensor. Uses Loop 1. Not suitable for use in metal doors
Honeywell 5819
Honeywell 5819 wireless shock processor and sensor
Three (3) zone shock processor.
Loop 1 = NC for Inertia Style External Shock Sensor. This input provides a suitable fast loop response of from 1ms to 20ms, based on dip switch setting
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact, unsupervised with no EOLR required
Honeywell 5819S
Honeywell 5819s wireless shock sensor and transmitter
Shock sensor and contact sensor.
Loop 1 = Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5819WHS
Honeywell 5819whs wireless transmitter with integrated shock sen
Three (3) zone shock processor.
Loop 1 = NC, Built-in Inertia Style Shock Sensor
Loop 2 = Reed Switch
Loop 3 = NC for Wired Contact
Honeywell 5820L
Honeywell 5820l super slim wireless door and window sensor
Slimline door and window sensor. Uses Loop 1.
Honeywell 5822T
Honeywell 5822t wireless garage tilt sensor
Garage tilt sensor.
Loop 1 = NC for Wired Contact, unsupervised, no EOLR used
Loop 3 = Tilt Switch
Honeywell 5834-2
Honeywell 5834 2 wireless 2 button security key fob
Two (2) button key fob. Dual-button inputs allowed. Uses three (3) loops total, for a possible three (3) inputs. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4
Honeywell 5834 4 wireless 4 button security key fob for honeywell security systems
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5834-4EN
Honeywell 5834 4en wireless enhanced 4 button security key fob
Four (4) button key fob. Dual-button inputs allowed. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible. Can only be used with the Lyric in Low-Security Mode (Green LED)
Honeywell 5853
Honeywell 5853 wireless glass break detector exterior
Glass break sensor. Uses Loop 1.
Honeywell 5869
Honeywell 5869 wireless commercial panic switch
Commercial panic switch. Uses Loop 1. Latches when tripped, key (provided) needed to reset it after it is tripped
Honeywell 5878
Honeywell 5878 wireless remote alarm keypad
Six (6) button key fob. Uses two (2) Serial Numbers, which both use Loops 1, 2, 3, 4. Up to eight (8) inputs possible.
Honeywell 5898
Honeywell 5898 wireless dual tec motion detector
Dual-tec motion sensor.
Loop 1 = Low Sensitivity Motion Sensor. Pet immunity is available for this loop. 50lb or 100lb pet immunity, selectable via DIP Switch 1
Loop 2 = High Sensitivity Motion Sensor.
Loop 3 = Temperature Sensor (High or Low, DIP Switch Selectable)
Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

With a new year comes reduced pricing on many of our great existing products. We have just dropped the prices on 73 of our existing offerings. You can certainly find something great to upgrade your existing system or use with a new installation. Let's check out these awesome products!


Before we go through and list each and every reduced price product, we figured we'd go through and talk about some of the ones that excite us the most. After all, sorting through a list of 73 products is pretty daunting. Our initial "best-of" list may help you find exactly what you're looking for. These products are great if you have an existing system, or if you are building a new system and want to add some cool accessories.

These products are presented in alphabetical order:

Alarm.com ADC-V723 Outdoor Camera


The ADC-V723 is the current flagship outdoor security camera for use with the Alarm.com platform. This simple, yet powerful camera makes the perfect addition to any home or small business. It can capture video at up to 1080p quality, and it makes use of High Dynamic Range (HDR) to improve image depth and luminosity.

Alarm.com T2000 Smart Z-Wave Thermostat

Alarm dot com t2000 smart thermostat


If you are still looking for a smart Z-Wave thermostat, then the ADC-T2000 is an outstanding entry-level option. It conveniently wires in place of your existing thermostat to give you smart control over your HVAC system. It can pair nicely with both the Alarm.com and Total Connect 2.0 platforms. You just need a compatible Z-Wave hub to get started.

DSC PG9312 Outdoor Door/Window Sensor

Dsc pg9312 wireless powerg outdoor door slash window contact


The DSC PG9312 is the premier outdoor contact sensor for any user with a PowerG-compatible security system. It offers a maximum magnet spacing gap of 1.75", which gives you more flexibility in choosing a location for the sensor and magnet. Like all PowerG Sensors, it offers a wireless range of up to 2 km away from the panel, as well as 128-bit AES encryption.

DSC PG9914 Motion Sensor

Dsc pg9914 powerg 915mhz out wireless motion detector


Anyone with a PowerG Security System looking to add a basic indoor motion sensor should turn to the DSC PG9914. This is a simple, yet effective motion sensor that is great for use in nearly any home or business. It offers a modest coverage area of 39 feet, and the sensor provides pet immunity for small animals weighing up to 85 lbs.

Encore FireFighter FF345 Smoke/CO Listening Module

Encore firefighter ff345 circular smoke detector takeover module


The Encore FireFighter FF345 is perfect if you have existing high-voltage smoke detectors that you want to integrate into a 345 MHz wireless system. The module can detect both the Temporal 3 sound of an activated smoke detector and the Temporal 4 sound of an activated CO detector. And if your high-voltage devices are one-go-all-go, then a single FF345 can takeover your entire network.

Honeywell 5822T Garage Door Tilt Sensor

Honeywell 5822t wireless garage tilt sensor


Also for 345 MHz system users, the Honeywell 5822T allows your system to monitor your garage door to see if it's opened or closed. This wireless sensor works great for security and automation purposes alike. You might even create a special smart scene that activates as soon as the 5822T detects that you garage door has been opened!

Honeywell IPCAM-WIC1 Indoor Camera

Honeywell lyric c1 wifi indoor 720p hd total connect security ca


The Honeywell IPCAM-WIC1 Indoor Camera is for anyone with an existing Total Connect 2.0 Video Monitoring service plan that they want to expand upon. This is a simple and straightforward camera that captures video at up to 720p quality. It can be easily rested on a desk or table, and no hard-mounting is required.

Qolsys IQ DW MINI-S Door/Window Sensor

Qolsys iq dw mini s encrypted wireless sensors for iq panel 2 qs


The Qolsys IQ DW MINI-S can be used by anyone with a 319.5 MHz wireless system, including the Qolsys IQ Panel 2 Plus w/ Legacy Interlogix & Qolsys Daughtercard. This is a straightforward door and window contact sensor that makes a nice addition to any compatible system. Its small and compact design allows for a tidy installation.

Please see our complete list of reduced price products in the table below, organized by product type:

Product Type
Products
Alarm Panels (6)
Cameras, Image Sensors, & Accessories (6)
Communicators (5)
Door/Window Sensors (8)
Environmental Sensors (2)
Garage Door Sensors (1)

Glass Break Detectors (5)
Hardwired Zone Expanders (2)
Home Automation & Smart Home (4)

Life-Safety Products (5)
Key Fobs & Panic Buttons (2)
Keypads & Desk Mounts (3)
Motion Sensors (8)
Power Supplies & Relays (2)
Sirens & Speakers (6)
Wireless Converters, Receivers, Repeaters & Translators

If you have any questions about these products or any of the other products on our site, including product compatibilities, please reach out to us. You may also contact us if you want to learn more about our monitoring services. The best way to reach us is to email support@alarmgrid.com. Or you may call us at (888) 818-7728. Remember that our support hours run from 9am to 8pm ET M-F. We look forward to helping you find the perfect product for your needs!

Tags: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Comments


Posted By

Actress Anna Faris, known for her comedic roles, suffered from a not-so-funny incident over the recent Thanksgiving Holiday. The actress and 12 members of her family were the victims of a carbon monoxide (CO) gas incident. The incident occurred in a North Lake Tahoe cabin they were renting.

Qolsys iq carbon

A representative from the North Tahoe Fire Protection District stated that the vacation cabin had carbon monoxide levels as high as 55 parts per million (ppm). Long-term indoor exposure should be no higher than 15 ppm. The structure did not have any carbon monoxide sensors installed to indicate such danger. Nevada state law requires CO alarms in all family dwellings.

Thankfully, Anna Faris and her family are okay following the incident. However, two of her family members visited the local emergency room. Doctors diagnosed them with CO poisoning, and they were perfectly fine after receiving some care. Firefighters from the North Tahoe FD immediately rushed to the cabin and saved Ms. Faris and her accompanying family shortly thereafter.

According to North Lake Tahoe Fire Official Erin Holland, the CO levels indicated inside the building would have caused a "fatality in a short period of time" had the rescue team not intervened. Faris made sure to send her sincere gratitude to the North Tahoe FD following the incident.

Honeywell 5800combo smoke heat and co detector

We have spoken about the dangers of carbon monoxide gas many times on the Alarm Grid blog. The odorless and tasteless gas kills hundreds of people every year in the United States. If it weren't for the quick work of local firefighters, a talented actress and her family may have fallen victim as well. They are lucky to be alive, and the rescue team deserves praise for the fact that any exposure was kept as minimal as possible.

As you know by now, it is crucial to have carbon monoxide sensors installed in your home. Ideally, you should have CO detectors enrolled with your security system. By pairing these devices with a system that has active monitoring service, you and/or a central station can receive alerts regarding any of your CO sensors that activate while you are away.

If your home has hardwired high-voltage CO sensors (as is required in most jurisdictions), you can indirectly integrate these devices with your alarm system using a wireless takeover listening module. We offer variants for 345 MHz, and 433 MHz wireless alarm systems. And if you don't have hardwired CO detectors in your home, then we sell plenty of standalone units that pair directly with alarm panels like any other sensor.

Encore firefighter ff345 circular smoke detector takeover module

When traveling, make sure that all on-site CO sensors and smoke detectors are working properly. If you have any doubts, ask the building operators to perform a test. This is a reasonable request that any property manager should be able to accommodate. Please note that we ARE NOT suggesting that you bring canned CO gas or canned smoke on an airplane for testing purposes. That could get you into a lot of trouble. Make arrangements for on-site testing, without bringing your own supplies.

It may also be a good idea to buy a cheap conventional battery-operated carbon monoxide sensor when you get to your vacation site. It may turn out that the place you visit does not have CO detectors. This was the case with Anna Faris and her family. We do not sell standalone battery-operated CO detectors on our website. But you can get most models between $10 and $20 from most department and hardware stores. Some models will even show you the detected parts per million for CO gas! If you are staying in a larger property, you may want to obtain multiple sensors.

Remember that our goal at Alarm Grid is to keep you and your loved ones safe. If you ever need help choosing a carbon monoxide sensor for your system, or if you would like to learn more about how we can monitor your home, please email us at support@alarmgrid.com. You are also invited to call us at (888) 818-7728 during our usual business hours of 9am to 8pm ET M-F. We look forward to hearing from you!

Tags: , , , , , , , , , , ,

Comments